16
28-0752/02
2.9 PORTION CONTROL PROGRAMMING (MVU) (NO TOP-OFF)
Multiple brands can be programmed at the same time to pour the same amounts for each size during this step.
Do this by selecting several brand buttons; however, the first button selected will illuminate and only its beverage
will pour. The other brands selected will flash slowly.
If multi-brand programming, do not set carbonated drinks and non-carbonated drinks at the same time because
carbonated drinks will foam.
NOTE:
The LED will blink twice and turn off if the brand has been programmed as a flavor shot instead of a drink.
You will need to reprogram the brand as a drink prior to setting the portion.
STEP 1
Press the S and XL at the same time for five
seconds to enter the portion setting mode.
The Pour/Cancel light will illuminate and the
shot light will blink two times.
STEP 2
Press the Brand button.
1. The selected brand’s LED will illuminate.
STEP 3
Fill cup 1/2 full with ice and place it under
the nozzle, push and hold a drink “size”
button until the cup is full.
Once the pour is completed, the LED will
blink slowly to indicate that a new pour
duration has been programmed for that key.
Summary of Contents for 23308 SERIES