VersaPour Manual
www.lancerbeverage.com
Page 4 of 13
Hoshizaki Lancer reserve the right to change specifications without notice.
Images are for illustration purposes only as product may vary.
No 066 30 October 2017
Closed Position
2. Safety Information
2.1. Safety Instructions
For your personal safety, and that of others working around you please read, understand, and
follow thoroughly all safety instructions included in this manual.
•
Review all applicable WHS (Work Health and Safety) regulations.
•
Learn how to operate the Appliance and use the controls properly.
•
Ensure that the Appliance is maintained according to service manual instructions.
•
Do not allow any unauthorised modifications to the machine.
3. Installation
3.1. Removal of Existing Valve
NOTE: Water, Syrup and CO2 systems must be depressurised prior to removing existing
valves
•
Turn OFF carbonated water supply and plain water supply to dispenser to depressurize the
system.
•
Disconnect syrup connector at syrup container.
•
Operate each valve to ensure complete depressurization of water and syrup in the system,
CO2 will still flow from the valve after water and syrup are emptied.
•
Turn OFF CO2 at the supply.
•
Operate each valve to depressurize CO2 from the lines.
•
Remove existing valve and mounting block. Reuse the mounting block screws
3.2. Installation of Valve
Caution
If dispenser is connected to electrical power, the unit must be properly
grounded to avoid possible fatal electrical shock or serious bodily injuries.
•
Slide I.D. panel up to expose cover mounting screw.
•
Loosen mounting screw, DO NOT REMOVE, then remove cover.
•
Turn both stems on mounting black to the closed position.
•
Lift up wire retainer and remove mounting block from the valve.
•
Replace inlet water and syrup o-rings on dispenser valve fittings.
Make sure to lubricate new o-rings with water or FDA approved
lubricant.
•
Connect wiring to pressure switch in product line (24 VAC power
supply required).
•
Install mounting block to valve plate using four (4) mounting screws removed from existing
mounting block.
•
Install valve on mounting block. Push wire retainer down. This will lock valve to mounting
block. White stems must be in closed position.
•
Turn on carbonator water supply and syrup supply to dispenser.