background image

6.4

PLUMBING DIAGRAM WITH VALVE WIRING

IS4-3

IS4-2

IS4-1

IS3-3

IS3-2

IS3-1

S4-1

S4-3

S3-3

S3-2

S3-1

S4-4

S4-2

S3-4

S0

S4-1

S4-3

IS4-1

IS4-2

IS4-3

S4-2

S4-4

V4

V3

S0

S3-1

S3-3

IS3-1

IS3-2

IS3-3

S3-2

S3-4

VA

LV

E HARNESS

FS30

V2

S0

S2-1

S2-3

IS2-1

IS2-2

IS2-3

S2-2

S2-4

V1

S0

S1-1

S1-3

IS1-1

IS1-2

IS1-3

S1-2

S1-4

IS2-3

IS2-2

IS2-1

IS1-3

IS1-2

IS1-1

S2-1

S2-2

S2-4

S1-2

S1-3

S2-3

S1-1

S1-4

V A L V E

M O U N T I N G

N O Z Z L

P A N E L

E

IS4-3

I N L E T

F I T T I N G S

CO

2

IS3-3

IS4-2

IS4-1

IS3-2

IS3-1

IS2-3

IS2-2

IS2-1

IS1-3

IS1-2

IS1-1

S1-3

S1-2

S1-1

S2-2

S2-1

S1-4

S3-1

S2-4

S2-3

S3-2

S3-3

S3-4

S4-2

S4-3

S4-4

S4-1

SODA1

SODA2

W

ATER2

SODA3

SODA4

W

ATER3

SODA

WA

TE

R

WHT

V4

NOT

YEL GR

Y

V4

USED

V4

WHT V4

RED WHT

BLU

V3

V3

YEL WHT V3

BLU

RED

V4

V3

BLU

V4

YEL

V3

RED

V3

V4

V4

V4

V3

V3

V3

V2

V2

V2

V1

V1

V1

BRN

B

LU

V1

V2

YEL

V2

YEL

V1

RED

V2

BRN BLK V1

RED GR

Y

V2

RED BLK V1

BLU BLK V2

RED GR

Y

V1

YEL GR

Y

V2

NOT

YEL GR

Y

V1

USED

DIAGRAM

PLUMBING DIAGRAM

WHT

WHT

RED

BLU

YEL

WHT

WHT

RED WHT

BLU

YEL WHT

WHT

WHT

RED

BLU

YEL

BLK

BLK

BLK

BLK

BLK

BLK

BLK

BLK

BLK

BLK

BRN BLK

RED GR

Y

YEL BLK

BRN BLK

RED GR

Y

YEL GR

Y

21

Summary of Contents for 14800 Series

Page 1: ...WIDE 8 BRANDS 12 FLAVORS 115V 60Hz 85 14810 12 ICE BEVERAGE DISPENSER ABOVE COUNTER MULTI BRAND 30 INCH WIDE 10 BRANDS 12 FLAVORS 115V 60Hz 85 14810N 12 ICE BEVERAGE DISPENSER ABOVE COUNTER MULTI BRA...

Page 2: ...TATION IT MAY ACTIVATE UNEXPECTEDLY DO NOT PLACE HANDS OR FOREIGN OBJECTS IN THE ICE STORAGE COMPARTMENT WHEN UNIT IS BEING SERVICED CLEANED OR SANITIZED UNPLUG DISPENSER FROM THE POWER SOURCE NOTE La...

Page 3: ...vd San Antonio TX 78219 Phone 800 729 1500 Local Service Name __________________________________________ Local Service Phone ________________________________________ ii TABLE OF CONTENTS SPECIFICATION...

Page 4: ...arton and remove interior packing D Lift carton up and off of the dispenser E Remove wood shipping base from the bottom of the dispenser Support dispenser while removing shipping base to prevent damag...

Page 5: ...a potable water supply must all be sized installed and maintained according to Federal State and Local laws The water supply must be protected by means of an air gap a backflow prevention device loca...

Page 6: ...g at the front of the unit See Figure 3 Check for leaks G Connect syrup supply lines to the 3 8 inch barb inlet fittings at the front of the unit See Figure 4 using BIB Bag In Box pumps Check for leak...

Page 7: ...asures syrup vacuum in the Pump Inlet Line When the Syrup Package is empty the Pump increases vacuum causing the device to shut off the gas pressure to stop the Pump The Lancer Sold Out automatically...

Page 8: ...tion may be used as long as it is prepared in accordance with the manufacturer s written recommendations and safety guidelines and provides 50 to 100 parts per million PPM available chlorine Sanitizin...

Page 9: ...ll the shroud up and out see Figure 8 Figure 7 Figure 8 H Using cleaning solution described in Section 2 2 and a clean cloth or soft brush clean all removable parts sides of Ice Bin Ice Chute and surf...

Page 10: ...tank and pressurize L Activate valve and draw sanitizing solution through line for a minimum of 60 seconds This will ensure line is flushed and filled with sanitizing solution Allow line to stand for...

Page 11: ...RATE AND ADJUST THE LANCER FS30 3 1 NORMAL OPERATION A Fill cup with desired amount of ice B Place cup under nozzle below desired brand C Select up to two 2 desired bonus flavors from those available...

Page 12: ...Y DISPENSE DELAY V 1 B1 DLY1 FS 16 SETUP PC MODE SET PC MODE OFF ON FS 16 SETUP PC TIME ON TIME MSEC 05000 FS 16 SETUP ICE STIR OFF OFF TIME MIN 00060 ON TIME MSEC 02000 CARB SENSORS UPPER LOWER 307 5...

Page 13: ...the relief valve Allow pressure on the regulator to drop and then lock the relief valve lever into place D Turn the pressure adjusting screw on the CO2 regulator clockwise until there is resistance Op...

Page 14: ...t of the pump 5 Unscrew the mounting bracket 6 Part should easily slide out for replacement maintenance 3 8 PRIMING THE SYRUP PUMP AT THE CORRECT PRESSURE For the Syrup Pump to operate correctly it is...

Page 15: ...d C PC Board defective C Replace PC Board D Solenoid bracket screwed D Unscrew solenoid bracket raise too low and not opening solenoid and re screw bracket completely 4 6 Push Chute Ice Door A Dispens...

Page 16: ...yrup A Check pressure and adjust supply not at minimum flowing pressure B Foreign debris in water and or B Remove flow control from syrup flow control suspected valve and clean out any foreign materia...

Page 17: ...ly seated B Reattach door assembly to dispenser 4 22 Circuit breaker tripping A Valve wire harness es A Detect short by disconnecting valve shorted to itself or Faucet harnesses from Switch Panel Plat...

Page 18: ...carbonator C Replace carbonator pump pump D Backflow preventer not D Replace backflow preventer allowing water to flow noting the flow direction arrow from pump to coldplate E Probe malfunctioning E R...

Page 19: ...16 NOTES Please refer to the Lancer web site www lancercorp com for information relating to Lancer Installation and Service Manuals Instruction Sheets Technical Bulletins Service Bulletins etc...

Page 20: ...1 2 3 4 11 10 9 5 13 14 6 8 7 12 20 19 18 15 16 17 21 23 22 24 25 29 27 26 28 30 31 32 34 35 36 38 37 39 40 41 33 6 ILLUSTRATIONS AND PARTS LISTINGS 6 1 FINAL ASSEMBLY 17...

Page 21: ...14 82 3286 01 Switch Assy MB 2L 2R 15 19 0262 01 Valve Assy LFCV 0 2 Syrup Injection Natural 16 19 0261 02 Valve Assy LFCV 4 5 Soda Water Gray Item Part No Description 18 Item Part No Description 17 1...

Page 22: ...9 8 11 ITEM PART NO DESCRIPTION QTY X X 1 02 0577 Grommet Rubber 3 G3002 X X 2 03 0368 Retainer Pin 1 Agitator IBD X X R 3 05 2293 01 Ice Shroud IC 1 X X R 4 23 1401 Agitator Assy 1 Helical IC HEX X 5...

Page 23: ...UMP BIN AGITATE ICE DOOR ICE MAKER OPTIONAL LOW ALARM ICE SWITCH BIN SWITCH OPTIONAL CANCEL ENTER LANCER FS16 KEY CARB PUMP TOP VIEW ICE LINK MDB ADDRESS SWITCH NUMBER SWITCH NUMBER 1 X O O O 2 O X O...

Page 24: ...T T I N G S CO 2 IS3 3 IS4 2 IS4 1 IS3 2 IS3 1 IS2 3 IS2 2 IS2 1 IS1 3 IS1 2 IS1 1 S1 3 S1 2 S1 1 S2 2 S2 1 S1 4 S3 1 S2 4 S2 3 S3 2 S3 3 S3 4 S4 2 S4 3 S4 4 S4 1 SODA1 SODA2 WATER2 SODA3 SODA4 WATER3...