LANBO LAC8000G User Manual Download Page 1

Pre

-

Water

-

Cooling Portable Air Conditioner

Model

:

LAC8000W

Model

:

LAC8000G

Model

:

LAC8000WG

USER MANUAL

LANBO

Summary of Contents for LAC8000G

Page 1: ...Pre Water Cooling Portable Air Conditioner Model LAC8000W Model LAC8000G Model LAC8000WG USER MANUAL LANBO ...

Page 2: ...nd that the appliance is installed properly in accordance with the instructions to avoid potential hazards Please keep this instruction manual for future reference if needed After unpacking the appliance please inspect it to verify it is not damaged If in doubt do not use the appliance and contact Lanbo Appliances customer service center CUSTOMER SERVICE For assistance or questions regarding your ...

Page 3: ...rtant Safety Instructions 4 Diagram of Portable Air Conditioner 5 Installation 7 Operation Instructions 8 Display and Operation Instructions 10 Specifications 11 Troubleshooting 12 Care and Maintenance 14 Warranty 15 ...

Page 4: ...f the power cord is damaged it must be replaced by the manufacturer or a qualified technician in order to avoid fire and electrical hazards Should abnormal operation occur such as a burning smell please disconnect power cord immediately and contact your local dealer If nobody is present to monitor the operation of the unit please turn it off and disconnect the power cord Do not splash or pour wate...

Page 5: ...5 Diagram of Portable Air Conditioner 1 Air Outlet 2 Oscillating Vertical Grill 3 Horizontal Grill 4 Control Panel 5 Castors 6 Air Filter 7 Power Cord ...

Page 6: ...6 8 Drain Inlet Cover 9 Water Level Window 10 Drain Outlet Cover 11 Exhaust Vent 12 Low Pressure Air Grid ...

Page 7: ...arpeted surfaces Do not attempt to roll the unit over objects The unit must be placed within reach of a properly rated grounded socket Never place any obstacles around the air inlet or outlet 11 of the unit Allow 10 to 12 inches of space from the wall with for efficient air conditioning and prevent overheating Keep product away from direct sunlight and other heat sources such as stoves radiators e...

Page 8: ...is 7 3 gallons Note Use low water pressure when filling tank as excessive pressure will cause water to overflow Please check the water level 9 when water reaches maximum level MAX stop filling tank and close the drain inlet cover 8 Excess water will be discharged from the drain outlet 10 Connect drain hose to drain outlet cover 10 to empty water tank Do not move the product during water filling Af...

Page 9: ...APACITY OPERATIONAL HOURS Cooling capacity 160 sq ft Hi Speed Cools for 8 hours Medium Speed Cools for 10 hours Low Speed Cools for 12 hours TIPS In the cold storage mode the compressor continues to work until the water in the tank is completely frozen before the compressor stops Allow 8 10 hours for optimum freezing time depending on room temperature Once the unit has been in operation for more t...

Page 10: ...idifier c Fan 3 Fan Speed Selection a Slow b Medium c Fast 4 Display Area 5 Increase Temp Button Max Temp 88 6 Decrease Temp Button Min Temp 61 7 Infrared Sensor 8 Left and Right Oscillation Note Temperature cannot be adjusted when in Dehumidifier Mode or Speed Mode Fan Speed cannot be adjusted in Dehumidifier Mode ...

Page 11: ... 11 Power Button ON OFF Specifications 1 Package Contents Portable air conditioner remote user manual fill hose with funnel drain hose 2 Product Size WxDxH 17 3 x 19 5 x 44 5 inches 3 Net Weight 84 9 lbs 4 Gross Weight 97 4 lbs 5 Package Size WxDxH 21 9 x 23 4 x 46 1 inches 6 Cooling Capacity 8000 BTU 7 Voltage 110 120 V 8 Frequency 60 Hz 9 Waterproof Level IP0 10 Refrigerant Injection Volume R600...

Page 12: ...ting temperature appropriate Set the temp lower than ambient temperature Are the doors and windows closed Close the door and windows Remote is not working Whether it has received strong interference such as static electricity abnormal power supply voltage Unplug it and plug it back in about 3 minutes and restart the AC Is the remote control within the receiving range The receiving range of the rem...

Page 13: ...ution Please contact service technician for assistance via service lanboappliances com 3 Warning If the following malfunctions occur please stop the unit and power it off immediately Do not attempt to repair or modify the AC by yourself please contact a service technician for immediate assistance The power cord is unusually hot or damaged Irregular or unusual operation A burning odor Water leakage...

Page 14: ...an be changed once a year Empty water in the tank then refill Draining To drain the water from tank open drain cover connect hose to the drain pipe and turn drain switch to the right Filter Cleaning It is recommended to clean filter every 1 2 months Open the filter cover on the left side of the air conditioner pull out the filter wipe it clean dry and then replace Seasonal Cleaning Preparing unit ...

Page 15: ...ds and admits that the goods sold here are mobile air conditioners The purchaser bears all risks of using these devices including deterioration humidity changes temperature changes leaks fire water damage mold mildew dryness and the risk of similar hazards Special note The warranty only applies to machines purchased and used in the United States Moreover if your product was purchased at any third ...