TAP9023 – LEVER DECK MIXER TAP
10-12
Guarantee (UK only):
Your tap has the benefit of a comprehensive manufacturer’s guarantee, details of which are shown on your Proof of Purchase Document. Any claim
during the period of the guarantee must be accompanied by the Proof of Purchase. The product must be correctly installed and operated in
accordance with the manufacturer’s instructions and used for normal domestic purposes. This guarantee does not cover accidental damage, misuse
or alterations which are likely to affect the product. The guarantee is invalid if the product is tampered with, or repaired by any unauthorised person.
The guarantee in no way affects your statutory or legal rights.
Care Instructions for your Kitchen Sink Mixer:
To maintain the appearance of this tap, ensure that it is regularly cleaned only using a clean, soft damp cloth. A solution of warm water and
a mild liquid detergent may be used where necessary, and then the fitting rinsed thoroughly and wiped dry. Any other cleaning action will
invalidate your warranty.
Abrasive cleaners, scouring cleaners and acidic cleaners
must not be used
under any circumstances. Avoid contact with all solvents
(including chlorinated solvents, ketones or acetones as these may result in surface deterioration or etching). Also avoid contact with any
harsh household chemicals such as oven cleaners, drain cleaners, rust removers, paint strippers and toilet bowl cleaners, bar keepers friend
or Brasso.
Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.
Important Technical Data:
Minimum operating pressure: 0.1 bar
Maximum hot water temperature: 70°C*
Maximum operating pressure: 5.5 bar*
Recommended hot water temperature: 46°C
Flow characteristics: Dual flow
*If these temperatures or pressures are exceeded, even for short periods, damage can result. In these instances a thermostatic mixing or pressure reducing
valve should be installed.
This product is manufactured in accordance with recognised European standards. Please ensure that your kitchen tap is fitted in
accordance with Local Water Byelaws.
Hot and cold supply pressures should be as closely balanced as possible for best results. Supply pipes should maintain the maximum
diameter until immediately before the fitting. The differential between the hot and cold water supply temperatures should be sufficient to
allow correct mixing function.
These installation guidelines have been prepared for your direction and you must exercise due care at all times. We do not accept
responsibility for problems that may occur through improper installation. Whilst assembling the tap take care not to accidentally loosen any
factory fixed assemblies.
This tap has been 100% assembly tested; therefore you may expect a small residual amount of water to remain in the tap when delivered.
Any water marks can be removed using the above care advice.
Installation Preparation:
All parts should be removed from their packaging and inspected for completeness and transport damage prior to installation.
Before installing the new mixer
it is essential that you thoroughly flush through the supply pipes
in order to remove any remaining
solder, swarf or impurities from your system. Failure to carry out this simple procedure could cause problems or damage to the workings of
the mixertap and invalidate the warranty.
We recommend installing isolation valves to both the hot and cold feed pipes in an accessible position. This will help to ease any future
required maintenance to the product.
Shut off the water heating system and ensure that the mains stopcock is closed. Ensure both the hot and cold water supplies are isolated
before commencing installation.
This mixertap requires two
∅
30-32mm tap holes at 180mm centres, if replacing an existing tap, remove the tap & clean the end of the feed
pipes using wire wool, the tap hole areas should be free from dirt and sealant. You should ensure that the product will both fit into the depth
of the mounting surface available and reach the required outlet positions before installation.
Loosely position the tap to check if any alteration to the existing pipework is required, if this is the case do this now.
ref/tap9023v2