background image

Instructions and Installation

LAM2703 60cm Stainless Steel

LAM2704 60cm Black

LAM2705 90cm Stainless Steel

LAM2706 90cm Black

Angled Extractor

www.howdens.com/appliance-registration

Summary of Contents for LAM2703

Page 1: ...Instructions and Installation LAM2703 60cm Stainless Steel LAM2704 60cm Black LAM2705 90cm Stainless Steel LAM2706 90cm Black Angled Extractor www howdens com appliance registration...

Page 2: ...See back page for product serial number...

Page 3: ...you doing your part to protect the environment By placing the marking on this product we declare on our own responsibility compliance to all of European safety health and environmental requirements s...

Page 4: ...t c a r t x E Control panel layout Care and maintenance General cleaning Grease filters Carbon filters Replacing the lamps Installation Methods of extraction Extraction via ducting Extraction via reci...

Page 5: ...or drugs Product must be disconnected from the mains during installation maintenance cleaning and repair procedures Repair procedures must always be performed by service agents The manufacturer shall...

Page 6: ...tor P 3i Intensive push twice Delay function The delay function will automatically switch off the hood 5 minutes after setting The delay function can be activated on all power functions When on press...

Page 7: ...ing Wipe the external surfaces of the appliance regularly using warm water and a mild detergent NEVER use abrasive cleaners or strong household cleaners as they may affect the appearance of the produc...

Page 8: ...y Refit grease filters Reconnect the power supply NOTE Thesuctionwillbe lowerwheninstalledinrecirculationmode thisisnormalandnotaproductfault Replacing the lamps The lamps on this model are service fi...

Page 9: ...ventilation in the room when the extractor is used at the same time as an appliance burning gas or other fuels Connect the external ducting kit to the outlet of the extractor Charcoal filters are not...

Page 10: ...ening your box you will the extractor body a two piece telescopic decorative chimney a bag of wall and screws two brackets and an outlet reducer 1 Main Extractor Body 2 Lower Chimney 3 Upper Chimney 4...

Page 11: ...ergy other than electricity E g gas boilers Ensure the requirements of the local authorities are adhered to concerning the discharge of exhaust air Ensure adequate room ventilation is provided when th...

Page 12: ...ity supply see electrical connections page We recommend an isolation switch that is accessible after installation 2 The outlet reducer maybe required depending on your ducting kit supplied separately...

Page 13: ...s are switched and disconnected at the same time The terminations labelled SUPPLY are the connections for the internal house wiring and the terminations labelled LOAD are for connection to the applian...

Page 14: ...NFORMATION General Total power consumption 142W Fuse 3 A Voltage Frequency 220 240 V 50 Hz Cable type section 0 75mm 3 core or equivalent Cable length max 1 5m Lamps 2X 1W LED natural white 4000k TROU...

Page 15: ...urer s instructions and used for normal domestic purposes This guarantee does not cover accidental damage misuse or alterations which are likely to affect the product The guarantee is invalid if the p...

Page 16: ...Product serial number Place sticker here ISSUE v1 050718...