Lamona LAM2504 Instructions And Installation Download Page 6

Exclusive to Howdens Joinery.co

Page _  5

Do not set your cooker hood less 

than 700mm above your cooker 

• When installed between adjoining

wall cabinets, the cabinets must not

overhang the hob.

• The edges of the cooker hood may

be sharp - be mindful of this as you

handle your appliance, especially

during installation and cleaning

• If the room where the cooker hood is

to be used contains a fuel burning

appliance such as a central heating

boiler then its flue must be of the

sealed or balanced flue type.

• If other types of flue or appliances are

fitted, ensure that there is an

adequate supply of air in the room

• When the hood is being used in

extraction mode, ensure that the

ducting is fire retardant and that

there are no bends greater than 90

degrees as this will reduce the

effiency of the hood

• Ensure the ducting for the extractor

mode has the same diameter as the

outlet hole all the way through.

r

Fire Safety

 

When installing the hood, ensure that 

the following recommended distances 

are observed between the heighest 

point on the hob top (including the 

burners) and the bottom of the 

cooker hood:

m

m

 

0

0

7

  :

s

r

e

k

o

o

C

 

c

ir

t

c

e

l

E

m

m

 

0

0

7

  :

s

r

e

k

o

o

C

 

s

a

G

m

m

 

0

0

8

 

:

s

r

e

k

o

o

C

 l

i

O

 

/

 l

a

o

C

• 

Never flambé cook under this cooker

hood.

• 

Dirty cooking oil is an even greater fire

risk

• 

Do not install above a cooker with a

high level grill.

Safety for Children

   

• Electrical products can be dangerous

to children. Keep children away from

the product when it is operating and do

not allow them toplay with or near the

product.

• The packaging materials will be

dangerous for children. Keep the

packaging materials away from children.

Please dispose of all parts of the

packaging according to the

environmental standards

Safety When Working with 

Electricity

• In case of any damage, switch off the

product and disconnect it from the

mains. To do this, turn off the fuse at

the fuse box.

• Make sure that the fuse rating is

compatible with the product.

User manual  LAM2504

Do not clean behind the

grease filter!

Always put lids on pans and ensure

that pans are always on hobs when

burners are lit.

• 

Remember that when in extraction

mode, your cooker hood is removing

air from your room. Ensure that

proper ventilation measures are

being observed.

Summary of Contents for LAM2504

Page 1: ...Instructions and Installation LAM2504 Black Curved Glass Chimney Extractor www howdens com appliance registration...

Page 2: ...See back page for product serial number...

Page 3: ...ing for possible hazards to health and property Warning possibility of electric shock This appliance is marked according to the European Directive 2012 19 EU on Waste Electrical and Electronic Equipme...

Page 4: ...Extractor Layout 06 Control Panel Layout 06 Care and maintenance 07 General Cleaning 07 Grease Filters 07 Carbon Filters 08 Replacing the Lamps 08 Installation 09 Methods of Extraction 09 Extraction...

Page 5: ...the product when your judgment or coordination is impaired by the use of alcohol and or drugs Product must be disconnected from the mains during installation maintenance cleaning and repair procedures...

Page 6: ...est point on the hob top including the burners and the bottom of the cooker hood m m 0 0 7 s r e k o o C c i r t c e l E m m 0 0 7 s r e k o o C s a G m m 0 0 8 s r e k o o C l i O l a o C Never flamb...

Page 7: ...wer Chimney Section 4 Fan and Light Controls 5 Extractor Body 6 Grease Filters 7 Light 8 Glass Canopy General Information Operation 0 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Extractor layout Control Panel Layou...

Page 8: ...abrasive cleaners Do not use a steam cleaner to clean the hood electrical components could be damaged or short circuit as a result The Grease Filters Clean the filter every month an excessive build up...

Page 9: ...tly Replacing the Lamps The extractor hood is with x2 LED lamp units that must only be replaced by a suitably qualified person The lights are powered by an electronic driver device and neither part is...

Page 10: ...Ducting Never use the hood in areas where devices with exhaust pipes connected to the outside are already operating unless perfect ventilation can be guaranteed Connect the external ducting kit to the...

Page 11: ...ill the extractor body a two piece telescopic decorative chimney a bag of wall and screws two brackets a ducting connector and reducer 1 Main Extractor Body 2 Lower Chimney 3 Upper Chimney 4 Upper Fix...

Page 12: ...uate room ventilation is provided when the extractor is used in the same room as appliances supplied with energy other than electricity Never duct into a hot air such as a central heating duct 320mm 7...

Page 13: ...kit if venting externally 4 Rest the chimney sections on the main extractor body and extend the upper section to the ceiling 5 Use the extended chimney sections to mark up the appropriate position of...

Page 14: ...labelled LOAD are for connection to the appliance IMPORTANT The wires in the mains lead are coloured in accordance with the following code Blue Neutral Brown Live Green Yellow Earth As the colours of...

Page 15: ...re any venting is not obstructed Clean the grease with warm water and mild detergent and or replace any charcoal The extractor works normaly but smells linger Clogged can reduce the product s and may...

Page 16: ...ed for normal domestic purposes This guarantee does not cover accidental damage misuse or alterations which are likely to affect the product The guarantee is invalid if the product is tampered with or...

Page 17: ...64 lux 0 W 56 dB In order to reduce the environmental impact e g energy use of the cooking process please be sure that your product is installed according to the user manual Ensure adequate ventilatio...

Page 18: ...Product serial number Place sticker here ISSUE v2 290917...

Reviews: