background image

Chimney Extractor

User & Installation Guide

HJA2480-1
LAM2401-1
LAM2407/8

www.howdens.com/appliance-registration

Summary of Contents for HJA2480-1

Page 1: ...Chimney Extractor User Installation Guide HJA2480 1 LAM2401 1 LAM2407 8 www howdens com appliance registration...

Page 2: ...2 See back page for product serial number...

Page 3: ...Identification Using your extractor Cleaning your extractor Maintenance Extractor cables Installation Trouble shooting Your guarantee Performance Information Contents Page 4 Page 4 Page 5 7 Page 8 Pag...

Page 4: ...point for recycling of electrical and electronic equipment Disposal must be carried out in accordance with local environmental regulations for waste disposal For more detailed information please cont...

Page 5: ...by the Department of the Environment the Building Standards Scotland Consolidated Regulations issued by the Scottish Development Department It is dangerous to alter the specifications or to modify th...

Page 6: ...outlet hole all the way through Keep young children from using playing with or tampering with the cooker hood Older children and infirm persons should be supervised if they are using the cooker hood D...

Page 7: ...naked flame from a gas burner or heat from electric hob zones without a pan on them Do not attempt to use the extractor if it is damaged in any way Never attempt to use it without the grease filters f...

Page 8: ...brackets outlet reducer six chimney fixing screws eight wall screws and eight rawl plugs and a cable grid Parts Identification 1 3 2 4 5 6 7 8 9 1 Main Extractor Body 2 Cable Grid 3 Upper Chimney 4 L...

Page 9: ...tton B Speed selection buttons Low Medium High C Light on off button Before operating the extractor make sure that it has been installed by a suitably qualified person as per the information contained...

Page 10: ...tion mode then be sure to replace the carbon filters every 3 6 months see section on Fitting the carbon filter A build up of grease could cause a fire hazard Never attempt to clean the area above the...

Page 11: ...the extractor Soak the grease filters in hot water and washing up liquid for about an hour Rinse them off thoroughly with hot water Repeat the process if required Refit the grease filters once they ha...

Page 12: ...HAVE DISCONNECTED THE EXTRAC TOR FROM YOUR MAINS SUPPLY 1 Remove the grease filters 2 Press the carbon filter against one end of the motor the fixing point is in the centre of the carbon filter 3 Turn...

Page 13: ...ement you will find it located in the light fixture which is inside the exposed section of the canopy Unscrew the light bulb that needs to be replaced and insert a new E14 28W halogen IMPORTANT Defect...

Page 14: ...rical connection YOUREXTRACTORISINTENDEDFORFITTEDANDPERMANENT INSTALLATION THE FUSE MUST BE RATED AT 3 AMPS WARNING THIS APPLIANCE MUST BE EARTHED It should only be connected by a competent person usi...

Page 15: ...beginning installation Check that the product purchased is of a suitable size for the chosen installation area In addition check whether there is an electrical outlet available that will be accessibl...

Page 16: ...ity of the materials in accordance with the type of wall and ceiling The wall and ceiling must be strong enough to take the weight of the extractor Do not tile grout or silicone this appliance to the...

Page 17: ...Fasten the support screws halfway in leaving them 10mm out of the wall 6 Hang the extractor onto the support screws 7 Fully tighten the support screws A and then screw the anchoring screws B through t...

Page 18: ...chimney 9 Take the upper chimney D and place inside the lower chimney section C 10 Take the flat bracket E and fasten to the lower chimney section using the chimney screws Do not fully tighten as the...

Page 19: ...ented extraction fit the grid D Upper Chimney F Upper Chimney Bracket E Lower Chimney Brace 12 Rest chimney sections on body Secure lower chimney section to body using chimney screws 13 Lift chimney s...

Page 20: ...action and recirculation modes To get optimum performance from your extractor the air should be taken out of the room via external ducting Unfortunately if you live in a flat or the hood is too far fr...

Page 21: ...placing The kitchen is not well ventilated enough If the extractor is set up for recirculation mode check if the carbon filters need replacing If the extractor is set up for extraction mode check that...

Page 22: ...are likely to affect the product The guarantee is invalid if the product is tampered with or repaired by any unauthorised person The guarantee in no way affects your statutory or legal rights What to...

Page 23: ...QBEP 190 8 m3 h Measured air pressure at best efficiency point PBEP 92 Pa Maximum airflow Qmax 329 3 m3 h Measured electric power input at best efficiency point WBEP 57 5 W Nominal power of the light...

Page 24: ...ciency QBEP 191 8 m3 h Measured air pressure at best efficiency point PBEP 88 Pa Maximum airflow Qmax 333 7 m3 h Measured electric power input at best efficiency point WBEP 58 2 W Nominal power of the...

Page 25: ...ciency QBEP 191 8 m3 h Measured air pressure at best efficiency point PBEP 88 Pa Maximum airflow Qmax 333 7 m3 h Measured electric power input at best efficiency point WBEP 58 2 W Nominal power of the...

Page 26: ...Product serial number Place sticker here Issue v1 030517...