(15189) Precipitation Sensor
Operating Instructions
Operating Instruction
Precipitation Sensors (15189) + (15189 H)
Attention!
In order to protect the tipping bucket
the dirt spiral must be inserted in the collecting
funnel.
A:
Tipping bucket bearings
B:
Fixed locking plate
C:
Relocatable locking plate
D: Reed
contact
E:
Magnet (here shown through inclination of the bucket)
F: Tipping
bucket
Mounting of the protective covering
When mounting the protective covering, please make sure
that the sign "close <-- --> open" (close < - > to) is positioned
above the
fi
xing screw. Especially when using the heated
version you have to pay attention to this step. This avoids
that the cable of the protective covering heating may block
the tipping bucket.