(15189) Precipitation Sensor 

  

 

Operating Instructions 

Operating Instruction
Precipitation Sensors (15189) + (15189 H)

Attention! 

In order to protect the tipping bucket 

the dirt spiral must be inserted in the collecting 
funnel. 

A: 

Tipping bucket bearings

B: 

Fixed locking plate  

C: 

Relocatable locking plate  

D: Reed 

contact

E: 

Magnet (here shown through inclination of the bucket)

F: Tipping 

bucket

Mounting of the protective covering

When mounting the protective covering, please make sure 
that the sign "close <-- --> open" (close < - > to) is positioned 
above the 

fi

 xing screw. Especially when using the heated 

version you have to pay attention to this step. This avoids 
that the cable of the protective covering heating may block 
the tipping bucket.

0HVVNDQWH

0HDVXULQJHGJH

6FKXW]PDQWHO

3URWHFWLYHFRYHULQJ

%HIHVWLJXQJVVFKUDXEH

)DVWHQLQJVFUHZ

0RQWDJHVRFNHO

0RXQWLQJSHGHVWDO

0RQWDJHPDVW

3ROHWXEH

,QQHQVHFKVNDQW

VFKOVVHO

+H[DJRQNH\

]X

DXI

FORVH

RSHQ

3

E

F

Summary of Contents for 15189

Page 1: ...er tipping bucket for precise precipitation measuring in regions with normal rain falls 4 cm 4 g water tipping bucket for precise precipitation measuring in regions with heavy rain falls tropical rain...

Page 2: ...ng plate C must be pushed back Now insert the tipping bucket F Make sure that the magnet E attached at the middle wall of the tipping bucket rests under the capsule with the embedded reed contact D Fi...

Page 3: ...ket F Tipping bucket Mounting of the protective covering When mounting the protective covering please make sure that the sign close open close to is positioned above the fixing screw Especially when u...

Page 4: ...ut For this application the clamps 1 and 6 are used In this case the current supply of the electronics with 100 A is not necessary The LAMBRECHT meteo data logger TROPOS is equipped with such a bounce...

Page 5: ...h 100 2 bucket tippings should have counted Rinse the sensor thoroughly for cleaning Clinging particles of dirt in the collecting funnel or outlet pipe may be removed with a piece of wood If unsatisfy...

Page 6: ...9 Precipitation Sensor Operating Instructions Operating Instruction Precipitation Sensors 15189 15189 H with heating without heating Connecting diagrams for use of the bounce free signal output standa...

Page 7: ...15189 Precipitation Sensor Operating Instructions Operating Instruction Precipitation Sensors 15189 15189 H with heating without heating Connecting diagrams to data logger TROPOS 7...

Page 8: ...on of the LAMBRECHT meteo GmbH for changes of system components These activities must be operated by a qualified technician 7 Prevent the ingress of liquids into the devices without permission Technic...

Reviews: