- 25
-
ENGLISH
MAIN COMPONENTS
1 3
2
4
5
6
18
17
7
8
9
16
15
14
19 10
11 12
13
Caption
1 electric valve, 1st phase
2 electric valve, 2nd phase
3 VE1 attachment base
4 fan
5 burner
body
6 no-return
valve
7 motor
8 switchboard
9 pump
10 electrode
11 nozzle
12 deflector
13 flow nozzle
14 thermometer
15 tank thermostat
16 equipment
17 pre-heater tank
18 transformer
19 flow nozzle regulation knob
FIG. 2
TECHNICAL CHARACTERISTICS
DESCRIPTION PNZ
30
50
75
100
130
Capacity
min.
18
19
29
37
65
kg/h
max.
32
56
86
110
140
kg/h
Thermal power
min.
202
216,5
330,4
421,6
740
kW
max.
364
638
980
1253
1596
kW
min.
176.400
186.200
284.200
362.600
637.000
kcal/h
max.
313.600
548.800
842.800
1.078.000
1.372.000
kcal/h
Motor
370
740
1500
1500
1800
W
Transformer
10/30
10/30
10/30
10/30
10/30
kV/mA
Total absorbed power
3.200
5.600
8.000
9.800
12.200
W
Power supply
Three-phase 230-400/50
Fuel
De-sulphured naphtha with low sulphur contents 12-15° E at 50° C