36
CAUTION:
When carrying out operations 7-8 to set the value of softened water, proceed as follows:
DOUBLE 35-50-65:
divide the actual value by 5 see table page 37
DOUBLE-PLUS 85-550:
divide the actual value by 100 see table page 38 - 39
In this way the displays will decrease by one number every 5 litres for the models DOUBLE 35-50-65 and by one number every 100 litres for the
models DOUBLE-PLUS 85
÷
550.
SEQUENCE OF THE REGENERATION ON TIME-VOLUME PROGRAM
NO.
OPERATIONS
KEYS TO PRESS
DATA ON DISPLAY
WHAT TO DO ON KEYBOARD
MEANING OF DATA SET
1
TIME
ADVANCE
08.56
Press key A “TIME” then
C “ADVANCE” to adjust the minutes
HOURS and MINUTES of the clock
e.g. 08.56
2
TIME
ADVANCE
08.56
Press key A “TIME” then
C “ADVANCE” to adjust the hours
3
TIME
08.56
Press key A “TIME” to store data set
4
PROGRAM
ADVANCE
0.2 30
Press key B “PROGRAM” then
C “ADVANCE” to adjust the minutes
ORE e MINUTI della Rigenerazione
Es. 0.230 Rigenerazione alle 2.30
5
PROGRAM
ADVANCE
0.2 30
Press key B “PROGRAM” then
C “ADVANCE” to adjust the hours
6
PROGRAM
ADVANCE
FF.04
Press key B “PROGRAM” and
DO NOT change the DATA displayed
This data is set for other programs
7
PROGRAM
ADVANCE
48 0.0
Press key B “PROGRAM” then
C “ADVANCE” to adjust the litres of softened water
e.g.. PLUS 550 with 30
°
F
set 112000:100 = 1120
VOLUME softened water:
e.g.. Double 65 with 30
°
F
set 13700 : 5 = 2740
8
PROGRAM
ADVANCE
48 0.0
Press key B “PROGRAM” then
C “ADVANCE” to adjust the litres of softened water
9
PROGRAM
ADVANCE
04.80
Press key B “PROGRAM” then
C “ADVANCE” to adjust the litres
Stock of softened water 5
÷
10%
e.g.. Double 125 with 30
°
F
10
PROGRAM
ADVANCE
04.80
Press key B “PROGRAM” then
C “ADVANCE” to adjust the litres
Softened water = 24000 litres 10%
Stock = 2400 litres Set 2400:5=480
11
PROGRAM
ADVANCE
AA 20
Press the key B “PROGRAM” then
C “ADVANCE” and adjust 20
Reading report of counter, one pulse
every 5 litres for Double 35-50-65
12
PROGRAM
ADVANCE
AA dd
Press key B “PROGRAM” then
C “ADVANCE” until both the TIME-VOLUME leds light up
Choice of “COMBINED TIME-VOLUME”
PROGRAM
13
PROGRAM
TIME
1C 06
Press key B “PROGRAM” then A “TIME”
to access the times. With the key C
“ADVANCE” you can change the data
Cycle no. 1 backwash
see TIMES TABLE
14
PROGRAM
ADVANCE
2C 30
Press key B “PROGRAM”.
With the key C “ADVANCE” you can change the data
Cycle no. 2 brine suction
see TIMES TABLE
15
PROGRAM
ADVANCE
3C 30
Press key B “PROGRAM”.
With the key C “ADVANCE” you can change the data
Cycle no. 3 slow rinse
see TIMES TABLE
16
PROGRAM
ADVANCE
4C 10
Press key B “PROGRAM”.
With the key C “ADVANCE” you can change
the data
Cycle no. 4 rapid rinse
sending water to salt container.
See TIMES TABLE
17
PROGRAM
4d 10
Press key B “PROGRAM”
FINAL PROGRAMMING STEP
11
PROGRAM
ADVANCE
AA 10
For the models 85
÷
550.
Press C “ADVANCE” and adjust 10
Report of litre counter reading, one
pulse every 100 litres
Summary of Contents for DOUBLE 125
Page 22: ......
Page 42: ......
Page 62: ......
Page 82: ......
Page 102: ...NOTE...
Page 103: ...NOTE...