Second Section - FOR THE INSTALLER
Connection, starting-up of the appliance and troubleshooting must be carried out by trained and qualified
fitters.
Caution
: indoor electric network as well as ambient where the appliance is installed, must strictly comply
with standards and safety regulations in force.
The Manufacturer cannot assume any responsibility for any damage to persons or property deriving
from the non-observance of the above-specified norms.
Place the appliance in the required position and
adjust the feet to level. Remove all protective
films and adhesive labels.
ELECTRICAL CONNECTION
Before connecting the machine,
check to make sure the voltage
outlet of the mains is
the same as the voltage specified
on the data plate of the machine.
A main switch must be installed between the
mains and the machine. This safety measure
also requires that the minimum distance between
the switch contacts is at least 3 mm and the
disconnection on all poles according to
EN 60204
(VDE 113)
.
Fuses on the main switch must be
16 A
.
The mains must be wired to be able to handle the
current drawn by the machine.The system must
also be provided with a proper ground lead in
accordance with the existings norms. The electric
cable must be of the following
type
H07RN-F
.
For the right choice of the cross section area
refer to the following table:
Cross Section area Total loading
mm² A
0,75
< 6
1
6
÷
10
1,5
10
÷
16
2,5
16
÷
25
The electrical safety of this equipment is only
assured if it is connected as follows.
It is necessary to connect the equipment to an
effective ground installation, as specified by the
electrical safety regulations in force.
Chack that this basic requirement is complied
with and, in case of doubt, ask for a careful
check of
the installation by a qualified personal.
In addition, the equipment shall be part of an
equipotential system, the effectiveness of which
should be checked according to the regulations in
force.
The connection should be made at the screw
marked by the respective label located on the
equipment back side ( ).
THE MACHINE SHALL BE
CONNECTED WITH AN EFFECTIVE
GROUND CLAMP.
The manufacturer declines any
responsibility for any damages
caused by lack of an effective
ground installation.
WATER CONNECTIONS
1) Connect the end of drain pipe
"S"
(fig.3 -
pag.30) th the drainage shaft.
Drain pipe should have slump to allow the
matters drain; under floor drain pipes should have
a dia. of 80-100 mm.
2) Connect inlet pipe
"E"
(fig.3 - pag.30) to a
Make sure there are no throttlings along the pipe.
The National and Regional Standards existing on
the subject must be rigorously respected.