Lambda Labs CX-1A Manual Download Page 8

Lambda Labs - Professional Acoustics                                                                                                                                                                CX-1A/B Manual

1.4.

 

EC

 

declaration

 

and

 

conformity

 

Lambda

 

Labs

 

Austria

 

Declares

 

that

 

the

 

following

 

products:

 

CX-1A

 

/

 

CX-1B

 

„EPS“

 

Express

 

Pin

 

System

 

Are

 

in

 

conformity

 

with

 

the

 

provisions

 

of:

 

Machinery

 

Directive

 

2006/42/EC

 

2011/65/EU, RoHS 

To

 

guarantee

 

the

 

safety

 

of

 

the

 

components,

 

the

 

following

 

standards

 

and

 

rules

 

have

 

been

 

complied:

 

EN

 

ISO

 

12100-1:

 

2011

 

(Mechanical

 

Safety)

 

DIN

 

18800

 

(Mechanical

 

Structure)

 

BGV-C1

 

/

 

DGUV

 

Regulation

 

17

 

&

 

18

 

(Mechanical

 

Standard

 

applied

 

in

 

Germany)

 

WEEE Declaration (Disposal) 

Electrical and electronic devices must be disposed of separately from household or municipal waste at the end of its operational 

lifetime. Please dispose of this product according to the respective national regulations or contractual agreements. If there are any 

further questions regarding the disposal of this product, please contact Lambda Labs. 

www.lambda-labs.com 

!

7

Graz, 17/02/2020 

 Steffen Kroschel, Chief Technology Officer (CTO)

Summary of Contents for CX-1A

Page 1: ...CX 1A CX 1B Manual Version 1 2 CX 1A CX 1B Manual Version 1 2 05 2020 2020 Lambda Labs All rights reserved This manual is optimized to save paper and to print 2 pages per DIN A4 sheet...

Page 2: ...SP Powercon Mains 12 2 2 1 3 Amplifier Module DSP Gain Control 13 2 2 1 4 Amplifier Module DSP Status Indicators 13 2 2 1 5 Amplifier Module DSP Selecting Presets 14 2 2 1 6 Amplifier Module DSP Prese...

Page 3: ...Lambda Labs Professional Acoustics CX 1A B Manual NOTES www lambda labs com 2...

Page 4: ...l information in this manual has been prepared to the best knowledge and with the utmost care Lambda Labs can not guarantee the accuracy of the documentation in all cases Lambda Labs disclaims any lia...

Page 5: ...g statutory provisions and safety regulations Qualified operators The operation as well as the planning of the setup may only be carried out by qualified personnel who are familiar and experienced wit...

Page 6: ...ng the entire installation process Always keep watching all rigging components and connection joints during the uplifting procedure Stop the uplifting procedure if any uncertainty occurs Lambda Labs r...

Page 7: ...ated rigging system please contact the Lambda Labs technical support and wait for further instructions Do NOT repair or exchange speaker parts or rigging components by yourself and without support of...

Page 8: ...011 Mechanical Safety DIN 18800 Mechanical Structure BGV C1 DGUV Regulation 17 18 Mechanical Standard applied in Germany WEEE Declaration Disposal Electrical and electronic devices must be disposed of...

Page 9: ...DAC 48kHz sample rate Frequency Response 80 20 000Hz 3dB Coverage Angle 100 horizontal x 100 vertical Monitor Angle 35 Crossover Frequency 2000Hz Sensitivity 94dB 1W 1m Connection XLR in out Powercon...

Page 10: ...the loudspeaker with various rigging equipment Therefore the loudspeaker can be flown vertically horizontally and upside down Refer to Chapter 2 2 4 as well Chapter 2 2 4 b Handle Recessed handles are...

Page 11: ...aker can be tilted down or upwards by adjusting the angle in 4 5 steps The maximum possible tilt angle is 13 5 The stand adapter is suitable to use with a stand distance rod tube diameter of 35mm Lamb...

Page 12: ...2 2 1 5 Chapter 2 2 1 6 b DIN 912 M4 Screws To protect the control panel from unauthorized access an optional module cover can be installed To do this the 4 upper M4 screws of the module must be remo...

Page 13: ...ly The grey Powercon connector at the right side provides the power supply link www lambda labs com 12 Danger The amplifier module can develop excessive heat Do NOT touch the surface of the amplifier...

Page 14: ...4 coloured signal LED displays as status indicators of the amplifier module Their meanings are www lambda labs com 13 Danger RISK OF ELECTRIC SHOCK Use grounded mains only Use undamaged cables and con...

Page 15: ...to lower the temperature to an uncritical level again When playing music this protective mechanism should only appear if the ambient temperature is very high and or the equipment is exposed to direct...

Page 16: ...read the MF 15A manual The Crossover Mode 140Hz has a 24dB oct Linkwitz Riley high pass filter at 140Hz Accordingly the subwoofer should have a 24dB oct Linkwitz Riley low pass filter characteristic a...

Page 17: ...he corners and follow an X order to unmount the other screws to avoid excessive stress in the Amplifier Module s heatsink 2 Put the Module Cover S over the Control Panel area and reinsert the removed...

Page 18: ...Speaker Flange for safe installation 2 Lift the loudspeaker slightly to release the locking mechanism of the Adjustable Speaker Flange tilt mechanism Always support and secure the loudspeaker sideway...

Page 19: ...and damage the speaker surface www lambda labs com 18 Ratchet or electric screwdriver HEX BIT Number 6 Wrench Size 6mm R Danger Do NOT use the 10mm Eye Bolt as a rigging item to fly the speaker with i...

Page 20: ...be used for all speakers from the CX and TX Series It can be combined with the with the Vari Clamp The T Bracket is preassembled and available in 2 versions of the EPS System M Mobile and I Installati...

Page 21: ...Lambda Labs Professional Acoustics CX 1A B Manual T Bracket www lambda labs com 20 Mobile Version M Installation Version I Mobile Version M Installation Version I T Bracket Vari Clamp...

Page 22: ...ket is preassembled and available in 2 versions of the EPS System M Mobile and I Installation version The installation version provides additional tamper proof properties to protect the components fro...

Page 23: ...rsion only The installation version provides tamper proof properties to protect the components from unauthorized access The Half Bracket can be combined with the Main Carrier to extend the fixing area...

Page 24: ...Do not use ANY other cleaning supplies on these areas We advice against the use of pressure water cleaning the Lambda Labs Loudspeakers and rigging parts in general High pressure cleaning is at your o...

Page 25: ...Lambda Labs Professional Acoustics CX 1A B Manual 2 4 Dimensions www lambda labs com 24 Dimensions mm Weight 8 4 kg 18 5 lbs 7 2 kg 15 9 lbs 320 253 258 371 376 CX 1A 371 376 CX 1B 300 253 258...

Reviews: