background image

WB50NBT 

 

Hardware Integration Guide 

Embedded Wireless Solutions Support Center:  
http://ews-support.lairdtech.com 

www.lairdtech.com/wi-fi

 

 

© Copyright 2016 Laird. All Rights Reserved

 

Americas: +1-800-492-2320 

Europe: +44-1628-858-940 

Hong Kong: +852 2923 0600

 

 

 

R

EVISION 

H

ISTORY

 

Version 

Date 

Notes 

Approver 

1.0 

29 Mar 2016 

Initial Version 

Connie Lin 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for WB50NBT

Page 1: ...User Guide WB50NBT Version 1 0 ...

Page 2: ...port Center http ews support lairdtech com www lairdtech com wi fi 2 Copyright 2016 Laird All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0600 REVISION HISTORY Version Date Notes Approver 1 0 29 Mar 2016 Initial Version Connie Lin ...

Page 3: ...initions 11 Mechanical Specification 15 Regulatory 16 Certified Antennas 16 FCC and IC Regulatory 16 FCC 17 Federal Communication Commission Interference Statement 17 End Product Labeling 18 Manual Information to the End User 18 Industry Canada 18 Industry Canada Statement 18 Antenna Information 19 Radiation Exposure Statement 19 Déclaration d exposition aux radiations 20 End Product Labeling 20 P...

Page 4: ...P N 145046120640829 Stacking height 4 0 mm Note See mounting for mating connector options Ethernet Interface 3 3 V signal level 10 100 Mbps RMII Reduced Media Independent Interface Asynchronous Serial Port Interfaces 3 3 V signal level Four wire UART with hardware handshaking up to 921 600 baud Full mode UART with synchronous clock to support USART interface SPI Interface 3 3 V signal level Five W...

Page 5: ...ed to an AP but not transmitting or receiving Mode 3 3 V Average Current Maximum Current 802 11a Transmit TBD TBD Receive TBD TBD Standby TBD TBD 802 11b Transmit TBD TBD Receive TBD TBD Standby TBD TBD 802 11g Transmit TBD TBD Receive TBD TBD Standby TBD TBD 802 11n 2 4 GHz Transmit TBD TBD Receive TBD TBD Standby TBD TBD 802 11n 5 GHz Transmit TBD TBD Receive TBD TBD Standby TBD TBD Sleep N A TB...

Page 6: ...ance CSMA CA Network Architecture Infrastructure and ad hoc Wi Fi Standards IEEE 802 11a 802 11b 802 11d 802 11e 802 11g 802 11h 802 11i 802 11n 802 11r Wi Fi Data Rates Supported 802 11a OFDM 6 9 12 18 24 36 48 54 Mbps 802 11b DSSS CCK 1 2 5 5 11 Mbps 802 11g OFDM 6 9 12 18 24 36 48 54 Mbps 802 11n OFDM HT20 MCS 0 15 Full Guard Interval 6 5 13 19 5 26 39 52 58 5 65 78 104 117 Mbps Short Guard Int...

Page 7: ...es according to individual country regulations All values for lowest data rate is nominal 2 dBm Others are 2 5dBm Note HT40 40 Mhz wide channels HT20 20 MHz wide channel 802 11a 6 Mbps 17 dBm 50 1 mW 54 Mbps 14 dBm 25 1 mW 802 11b 1 Mbps 17 dBm 50 1 mW 11 Mbps 17 dBm 50 1 mW 802 11g 6 Mbps 17 dBm 50 1 mW 54 Mbps 14 dBm 25 1 mW 802 11n 2 4 GHz 6 5 Mbps MCS0 17 dBm 50 1 mW 65 Mbps MCS7 13 dBm 20 mW ...

Page 8: ...4 Algorithm Temporal Key Integrity Protocol TKIP RC4 Algorithm Advanced Encryption Standard AES Rijndael Algorithm Encryption Key Provisioning Static 40 bit and 128 bit lengths Pre Shared PSK Dynamic 802 1X Extensible Authentication Protocol Types EAP FAST EAP TLS EAP TTLS PEAP GTC PEAP MSCHAPv2 PEAP TLS LEAP Compliance Note Pursuing MIC and KC certifications is currently TBD ETSI Regulatory Domai...

Page 9: ...erated over the maximum limit may cause permanent damage to the device These are stress ratings only functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied Exposure to absolute maximum rated conditions for extended periods may affect device reliability Recommended Operating Conditions and DC Power Electrical ...

Page 10: ...er Pull Up Pull Down or nothing is enabled ST Indicates if Schmitt Trigger is enabled TR Tri state GPIO 1 6 PIO I PU ST LED 0 2 PIO I PU ST STAT_0 STAT_1 PIO I PU ST SHDN O NRST I PU ST BINT I PU ST WKUP I PU ST DDM DDP HDMA HDPA HDMB HDPB O PD E_TXEN E_TX 0 1 E_RXER E_RX 0 1 E_MDC PIO I PU ST E_MDIO E_CRSDV E_REFCK E_RST_L E_INT TBD BT_PCM_OUT BT_PCM_IN BT_PCM_SYNC BT_PCM_CLK TBD XPABIAS50 XPABIA...

Page 11: ... Slave In Leave open 10 DRXD DBGU I VCC3_3 Console Debug Serial Input Leave open 11 SPI_MISO I VCC3_3 SPI Master In Slave Out Leave open 12 DTXD DBGU O VCC3_3 Console Debug Serial Output Leave open 13 GND Ground Must be connected to GND 14 GPIO_5 GPIO I O VCC3_3 General I O 5 Leave open 15 SPI_CLK O VCC3_3 SPI Programming Clock Master O Slave I Leave open 16 GPIO_6 GPIO I O VCC3_3 General I O 6 Le...

Page 12: ... O VCC3_3 Ethernet Transmit Enable Leave open 36 TW_CLK I O VCC3_3 Two wire Serial Clock Leave open 37 E_CRSDV I VCC3_3 Ethernet Carrier Sense and Valid Data Leave open 38 GND Ground Must be connected to GND 39 E_RXER I VCC3_3 Ethernet Receive Error Leave open 40 TXD_1 O VCC3_3 Serial UART1 Transmit Data 1 Leave open 41 E_RST_L O VCC3_3 Ethernet Reset Leave open 42 RXD_1 I VCC3_3 Serial UART1 Rece...

Page 13: ... to GND 62 GND Ground Must be connected to GND 63 MC_CLK O VCC3_3 SDIO Multimedia Card Clock Leave open 64 S_CLK_0 I O VCC3_3 UART0 Serial Clock Leave open 65 GND Ground Must be connected to GND 66 TXD_0 O VCC3_3 UART0 Serial Output Leave open 67 MC_CDA I O VCC3_3 SDIO Multimedia Card Command Leave open 68 RXD_0 I VCC3_3 UART0 Serial Input Leave open 69 GND Ground Must be connected to GND 70 GND G...

Page 14: ...nse signal from peripheral to host active low Leave open 90 BT_PCM_IN I VCC3_3 PCM Signal Input Leave open 91 GND Ground Must be connected to GND 92 BT_PCM_OUT O VCC3_3 PCM Signal Output Leave open 93 DDM I O USB Device Data Negative Leave open 94 GND Ground Must be connected to GND 95 DDP I O USB Device Data Positive Leave open 96 BT_PCM_CLK I O VCC3_3 PCM Clock Signal Leave open 97 GND Ground Mu...

Page 15: ...TE coexistence Leave open 109 GND Ground Must be connected to GND 110 GND Ground Must be connected to GND 111 GND Ground Must be connected to GND 112 DEBUG_UART_TXD O VCC3_3 WLAN debug UART TXD output Leave open 113 GND Ground Must be connected to GND 114 GND Ground Must be connected to GND 115 VDD_BU Module Back up Power 3 3V 116 GND Ground Must be connected to GND 117 VCC3_3 3 3V Module Power 11...

Page 16: ... 15 5 35 GHz 4 dBi 5 6 GHz Laird MAF95310 Mini Nano Blade Flex PCB Dipole IPEX MHF 2 79 dBi 2 4 GHz 3 38 dBi 5 GHz Laird NanoBlue IP04 PCB Dipole IPEX MHF 2 dBi 2 4 GHz only Ethertronics WLAN_1000146 Isolated Magnetic Dipole IPEX MHF 2 5 dBi 2 390 2 490 GHz 3 5 dBi 4 900 5 100 5 150 5 350 5 70 5 900 GHz FCC AND IC REGULATORY Model US FCC CANADA IC WB50NBT SQG WB50NBT 3147A WB50NBT The WB50NBT is d...

Page 17: ...fications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Im...

Page 18: ...de all required regulatory information warning as show in this manual Industry Canada Industry Canada Statement This device complies with Industry Canada s license exempt RSSs Operation is subject to the following two conditions This device may not cause interference and This device must accept any interference including interference that may cause undesired operation of the device Le prése t appa...

Page 19: ...ted for devices in the band 5725 5850 MHz shall be such that the equipment still complies with the EIRP limits specified for point to point and non point to point operation as appropriate and Operations in the 5 25 5 35GHz band are restricted to indoor usage only Avertissement i les dispositifs fonctionnant dans la bande de 5150 à 5250MHz sont réservés uniquement pour une utilisation à l intérieur...

Page 20: ...pour ce module installé Important Note In the event that these conditions cannot be met for example certain laptop configurations or co location with another transmitter then the Canada authorization is no longer considered valid and the IC ID cannot be used on the final product In these circumstances the OEM integrator will be responsible for re evaluating the end product including the transmitte...

Page 21: ... dBi 5 25 GHz 3 4 dBi 5 875 GHz Laird NanoBlade IP04 PCB Dipole IPEX MHF 2 dBi 2 4 2 5 GHz 3 9 dBi 5 15 5 35 GHz 4 dBi 5 6 GHz Laird MAF95310 Mini Nano Blade Flex PCB Dipole IPEX MHF 2 79 dBi 2 4 GHz 3 38 dBi 5 GHz Laird NanoBlue IP04 PCB Dipole IPEX MHF 2 dBi 2 4 GHz only Ethertronics WLAN_1000146 Isolated Magnetic Dipole IPEX MHF 2 5 dBi 2 390 2 490 GHz 3 5 dBi 4 900 5 100 5 150 5 350 5 70 5 900...

Page 22: ...t den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999 5 EG befindet Eesti Estonian Käesolevaga kinnitab tootja nimi name of manufacturer seadme seadme tüüp type of equipment vastavust direktiivi 1999 5 EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele English Hereby name of manufacturer declares that this type of equip...

Page 23: ...ak Polski Polish Niniejszym nazwa producenta oświadcza ΝżeΝ nazwa wyrobu jest zgodny z zasadniczymi wymogamiΝorazΝpozostałymiΝstosownymiΝpostanowieniamiΝDyrektywyΝ1999 5 EC Português Portuguese Nome do fabricante declara que este tipo de equipamento está conforme com os requisitos essenciais e outras disposições da Directiva 1999 5 CE Slovensko Slovenian Ime proizvajalca izjavlja da je ta tip opre...

Reviews: