Summary of Contents for SDC-WB40NBT

Page 1: ...Americas 1 800 492 2320 Option 3 Europe 44 1628 858 940 Hong Kong 852 2268 6567 x026 www lairdtech com wireless SDC WB40NBT Quick Start Guide Version 1 0 ...

Page 2: ...DC WB40NBT Americas 1 800 492 2320 Option 3 Europe 44 1628 858 940 Hong Kong 852 2268 6567 x026 www lairdtech com wireless 2 SDC WB40NBT_QSG_v1_0_201211 REVISION HISTORY Revision Description 1 0 03 21 2012 Initial version ...

Page 3: ...567 x026 www lairdtech com wireless 3 SDC WB40NBT_QSG_v1_0_201211 Contents Inventory of Equipment 4 Hardware Installation and Configuration 4 Software Installation and Configuration 6 Using Linux on the SDC WB40NBT 8 Common Terms 8 Scanning for Available Access Points 8 Establishing a Wireless Connection 8 ...

Page 4: ...verse SMA Connector 3 Wi Fi Antenna with reverse TNC Connector 2 USB to RS 232 DB9 DB25 Adapter 1 Power Supply 9V 2 5A negative center with Wall US European adapter Cable HARDWARE INSTALLATION AND CONFIGURATION To connect the SDC WB40NBT to a computer follow these steps 1 If not already installed attach the four riser assembly mounting screws onto the breakout board These screws are installed from...

Page 5: ...ector situated near the four mounting screws that were installed in step 1 2 Connect an antenna with an SMA connector to the antenna port STA4 3 Connect the USB to RS232 adapter to the position labeled ST3 DBU RS232 on the Hoeft Wessel breakout board Note Do not plug the USB to RS232 cable into a host PC at this time Its driver must first be installed onto the host PC See Software Installation and...

Page 6: ...9 DB25 Adapter 1 Power supply 9V 2 5A negative center with wall US European adapter Cable To set up the SDC WB40NBT follow these steps 1 Load the driver for the USB to RS232 cable using the CD provided To load the driver follow these steps a Insert the CD labeled Driver and Utility CD in your computer s CD drive b From your CD drive navigate to D Prolific PL2303HXD c Click on PL2303_Prolific_Drive...

Page 7: ...SB Comm Port Remember this COM port number h To adjust the serial port settings navigate to Setup Serial port Adjust the settings as needed according to the following Port The previously chosen port may not be set here Change to the correct COM port number if necessary Baud Rate 115200 Tera Term defaults to 9600 baud communications Data 8 bit Parity None Stop 1 bit Flow Control None i Press OK to ...

Page 8: ... Then type the following wl scanresults Note If the wl scanrestults command indicates the device is not ready it may be still creating the list of available access points Wait a few seconds and type the wl scanresults command again Establishing a Wireless Connection The wireless bridge is pre configured with a script S45wireless that loads the device driver for the radio and attempts to make a con...

Reviews: