Please read all instructions carefully before attempting to 

install and use this product. 

The CMS38606P and all associated equipment should be installed 

in accordance with all applicable local and national electrical code 

guidelines to ensure safe operation.

STANDARD MOUNTING

A  threaded  post  on  the  back  of  the  antenna  and  a  supplied 

mounting  nut  are  the  primary  mounting  method  when  access  is 

available  to  both  sides  of  the  mounting  surface,  such  as  a 

suspended ceiling tile. Mark the desired mounting location on the 

tile  and  cut  a  ø40mm  (1.57")  hole  for  threaded  post.  Feed  the 

cables through the hole and secure the antenna with the mounting 

nut. (See figure 1).

PRECAUTION

For best PIM results:

 

PARAMETER

Frequency

380-520 MHz

600-960 MHz

1395-1435 MHz

1690-6000 MHz

VSWR (Max)

3.0:1 (380-520 MHz)

2.0:1 (600-960 MHz)

2.0:1 (1395-1435 MHz)

2.0:1 (1690-6000 MHz)

Max Gain

Polarization

Vertical

PIM, 3rd order, 2X20W

50Ω

Power

50W @ ambient temp 25

C (77

o

F)

RF Connector

Model specific

Radome Color

White

Operating Temperature

-30°C +70°C

Storage Temperature

-40°C +85°C

Water/Foreign Body Ingress

IP-67

Antenna Weight

0.8kg (1.76 lbs)

<-150dBc 

PERFORMAN

CE 

CMS38606P

Laird Model Number

LOCATION

For  the  best  results,  mount  the  antenna  near  the  center  of  the 

coverage area. A line-of-sight path between the antenna and active 

floor  locations  generally  works  best.  Although  microwave  signals 

penetrate cubical dividers and interior walls with little attenuation, 

reinforced  block  attenuate  signals  or  cause  multipath,  a  condition 

where reflected signals interfere with the primary signal path. Avoid 

mounting next to a column or vertical support that could create a 

''shadow zone'' of reduced coverage to one portion of the room.

Make sure the connectors are clean and free from any 

metal flakes/dirt & tighten the connectors using torque 

wrench according to connector torque specification below.

Avoid extreme bending to the cable. Do not remove 

the dust cap from connectors when not in use.

1.

2.

Americas: +1.847 839.6907

[email protected]

Europe: +44.1628.858941 
[email protected]
Asia: +86.21.5855.0827.127

[email protected]

www.lairdtech.com

PIM Test Frequencies

UHF Band (380-384MHz)

Low Band Cellular (776-786MHz) 

High Band Cellular (1870-1910MHz)

SPECIFICATIONS

Figure 1

Patent Pending

Impedance

Flammability

UL94-V0

3

.

1

 dBi @ 380-520 MHz 

2.9 dBi @ 600-960 MHz 

5.4 dBi @ 1395-1435 MHz 

7.0 dBi @ 1690-6000 MHz

 