Revo 18|36 Lathe \ Electrical Saftey
Electrical Saftey
Power Connections
A separate electrical circuit should be used for each machine. This circuit should not be less than the
wiring listed below and should be protected with an appropriate circuit breaker based on the total running
and start-up amperage's (listed below). If an extension cord is used, use only 3-wire extension cords
which have 3-prong grounding type plugs and matching receptacle which will accept the machine’s plug.
Running on a different voltage than stated below will damage the machine. Never run the
machine in wet or damp conditions.
MLAREVO 1836-110-150
VOLTAGE
115V
PHASE
1Ph
HERTZ
60Hz
FULL LOAD AMPERAGE
See Motor Plate
Below are RECOMMENDATIONS to be used for this machine based on the above
information. Variables outside of our control are:
·
Actual voltage supplied to the machine
·
Electrical code that must be met in your local province.
An electrician will verify that all the demands are met to properly wire the machine. If you have
absolutely any doubt when wiring this machine - please consult with a qualified electrician.
PLUG/RECEPTACLE
5-15
WIRING (Gauge)
14 Ga.
CIRCUIT BREAKER
15A
MLAREVO 1836-220
VOLTAGE
230V
PHASE
1PH
HERTZ
60Hz
FULL LOAD AMPERAGE
See Motor Plate
Below are RECOMMENDATIONS to be used for this machine based on the above
information. Variables outside of our control are:
·
Actual voltage supplied to the machine
·
Electrical code that must be met in your local province.
An electrician will verify that all the demands are met to properly wire the machine. If you have
absolutely any doubt when wiring this machine - please consult with a qualified electrician.
PLUG/RECEPTACLE
6-15
WIRING (Gauge)
14 Ga.
CIRCUIT BREAKER
15A