Dake Corporation
1809 Industrial Park Dr
Grand Haven, MI 49417
974355-2
18
REV032023
Wrong tooth pitch
Use the blade calculator to
determine the correct pitch or
consult your blade provider
Low quality and/or dull blade Speak with blade provider
and sharpener
Poor clamping pressure
causing the part to move
Check the material for
tightness before cutting
Check the condition of the
jaw faces
Insufficient coolant or
incorrect type of coolant
Check the level of coolant in
tank and increase the flow of
coolant.
Talk to your coolant provider
Premature Blade Wear
Wrong blade being used
Consult your blade provider
for adequate blade
Wrong cutting speed or feed
Insufficient coolant or
incorrect type of coolant
Check the level of coolant in
tank and increase the flow of
coolant
Talk to your coolant provider
Blade Vibration
Wrong blade being used
Consult your blade provider
for adequate blade
Poor clamping pressure
causing the part to move
Check the material for
tightness before cutting
Check the condition of the
jaw faces
Dimensions of the solid
section too large with respect
to the maximum cutting
dimensions
Check the cutting capacity of
the saw
Blade diameter incorrect
and/or too large
Decrease blade diameter
SYMPTOM
CAUSE
SOLUTION
Blade sticks in the cut
Too fast of an advance on the
material
Decrease the level of
downward feed
Cutting speed too slow
Increase blade speed
Wrong blade
Use the blade calculator to
determine the correct pitch or
consult your blade provider
Use a higher quality of blade