Dake Corporation
1809 Industrial Park Dr
Grand Haven, MI 49417
974355-2
9
REV032023
Locations of shields:
•
Grey metal shield screwed onto the blade head. (REF. A)
•
Self-regulating mobile blue plastic shield fitted coaxially with the fixed shield. (REF. B)
*
picture may vary by model*
Electrical Equipment:
According to European Standard “CENELEC EN 60 204-1” which simulates modification,
publication (IED 204-1)
•
The electrical equipment ensures protection against electric shock as result of direct or
indirect contact. The active parts of this equipment are housed in a box so that access is
limited by screws can only be removed with a special tool; the parts are fed with
alternating current at low voltage (24V).
•
This equipment is protected against splashes of water and dust.
•
Protection of the system against short circuits is ensures by means of rapid fuses and
earthing; in the event of motor overload, protection is provided by thermal probe.
•
In the event of incorrect operation or of dangerous conditions, the machine may be
stopped immediately by pressing the red emergency stop button.
•
In the event of a power cut, the specific start-up button must be reset.
•
This machine has been tested in conformity with point 20 of EN 60204.