Lafferty Equipment Manufacturing, Inc.

Installation & Operation Instructions

Model # 950810 · Fogger Recycling On / Off Controller - 180 CFM

REQUIREMENTS

Electric

120V / 2 Amps

Compressed Air

Up to 180 CFM

www.laffertyequipment.com

501-851-2820

 

OVERVIEW

When activated, the Fogger Recycling Controller starts fogger operation immediately and runs for a predetermined period of time then switches off for a
predetermined period (the Delay cycle), after which the fogging cycle starts again. The complete cycle will repeat until the unit is switched off or reprogrammed. The
Run and Delay times are set independently by rotating the arrow on a dial to select the number of hours desired for the cycle --up to 6 hours each. Hash marks
indicate 15 minute increments. 

• 

NOTE: The total air CFM requirement of all the foggers connected to this controller must be less than 180 CFM, which is the air CFM capacity of the controller's 1/2

inch solenoid. (For a higher air capacity up to 460 CFM, see controller model #950812.) 

W A R N I N G !

  R E A D   A L L

I N S T R U C T I O N S   B E F O R E

U S I N G   E Q U I P M E N T !

Lafferty Equipment Manufacturing, Inc. • 5614 Oak Grove Road • North Little Rock, Arkansas 72118