User Guide

EN

Summary of Contents for SimNewB

Page 1: ...www laerdal com SimNewB User Guide EN...

Page 2: ......

Page 3: ...Simulation Choose Pupils 16 Preparing for Simulation Lubrication 17 LubricateTools 17 Lubricate SimNewB 17 Use Intubation 18 Use Ventilation 19 Use CPR 20 Use Unilateral Left Thorasentisis Midaxillary...

Page 4: ...rove neonatal resuscitation and to meet the specific learning objectives of neonatal resuscitation protocols Focusing on the first 10 minutes of life SimNewB provides realistic training for critical i...

Page 5: ...g either LLEAP or SimPad Plus allow vital signs to be displayed on a simulated Patient Monitor optional Both SimNewB and the Patient Monitor can be operated wirelessly Note Find SimPad PLUS User Guide...

Page 6: ...SimNewB SimNewB SimNewB 6 Items Included Storage...

Page 7: ...hing with variable rate and depth Bilateral and unilateral chest rise and fall Normal and abnormal breath sounds Anterior lung sounds Unilateral breath sounds Simulated Oxygen Saturation Unilateral th...

Page 8: ...on WiFi LAN Indicator Power Indicator External Power Port Ethernet Port Power Indicator Status On Simulator booting Software updating Battery charging Failure updating software 10 secs Battery low Ser...

Page 9: ...Fully charge the battery before first use 9 Charge Battery charging Battery fully charged 10 secs Battery low...

Page 10: ...AP or SimPad PLUS with WiFi WiFi enabled WiFi connected to device No connection Configure Network with Ethernet cable Note For detailed connection instructions download the Wireless Setup Overview fro...

Page 11: ...11 Overview Pulses and Sounds Pulses and sounds are controlled in SimPad PLUS or LLEAP Umbilical and Brachial Pulses Vocal Lung and Heart Sounds...

Page 12: ...e Insert the module with a finger do not use force A suction catheter 100 mmHg will remove the meconium module A tether has been added to ensure removal of the object Notes Do not add lubricant to the...

Page 13: ...and fill with maximum 1 ml blood Place Umbilical Cord into naval Twist to lock in place www laerdal com support How to Videos 13 Preparing for Simulation UmbilicalVenous Catheterization 1 ml Insert b...

Page 14: ...or Simulation UmbilicalVenous Catheterization 14 LargeVolume Infusions If scenario requires large volume infusions of fluid exceeding 10 ml connect empty drain bag to simulator www laerdal com support...

Page 15: ...15 Preparing for Simulation IO Leg LargeVolume Infusions Connect empty drain bag to heel to prepare for intraosseous large volume infusion of medication...

Page 16: ...16 Preparing for Simulation Choose Pupils Rotate the eyes to select pupil type...

Page 17: ...to insertion into the airway Non lubricated instruments and tubes may cause damage to the airway Only use Silicone Lubricant provided by Laerdal Medical Lubricate SimNewB Lubricate the front of the si...

Page 18: ...18 Use Intubation Perform nasal or oral intubation...

Page 19: ...19 Use Ventilation Perform ventilations with visual chest rise Correct head tilt opens airway Incorrect head tilt closes airway Stomach distention...

Page 20: ...20 Use CPR Perform basic CPR...

Page 21: ...21 Use Unilateral LeftThorasentisis Midaxillary Access Insert needle between the 4th and 5th intercostal space Caution Insertion of the needle outside this area may cause damage to the simulator...

Page 22: ...22 Use UmbilicalVenous Catheterization Simulated umbilical cord with venous and arterial access Simulated blood flashback on cannulation...

Page 23: ...23 Use LargeVolume Infusions For large volume infusions of fluid exceeding 10 ml connect empty drain bag to simulator...

Page 24: ...24 Use IO Leg Insert needle drill in highlighted area Note The IO Leg should be patched or replaced after each simulation when using fluids...

Page 25: ...ttings Lung Recruitment Settings Change between 4 and 7 opening breaths before you start session SimPad Plus Activate Lung Recruitment in Manual Mode before starting scenario 2 Select ventilation numb...

Page 26: ...26 Use Lung Recruitment Settings LLEAP Activate Lung Recruitment in Manual Mode before starting scenario 1 Press 2 Check this box to engage Lung Recruitment 3 Select ventilation number...

Page 27: ...Levels to simplify operation when running sessions in Manual Mode Each Level 0 5 represents a predefined set of vital signs Toggle directly between Levels as the session progresses to change the clin...

Page 28: ...If a training session involves the use of fluids in the Umbilical Reservoir and IO Leg drain the fluid immediately after the training session Skin Use a lint free cloth to remove dirt and dust Clean...

Page 29: ...Care Cleaning 29 Cleaning IO Leg Module Remove remaining fluid from internal reservoir and flush with water Repeat until clean...

Page 30: ...3 1 2 4 5 Care Cleaning 30 Cleaning Umbilical Reservoir Remove remaining fluid from internal reservoir and flush with water Repeat until clean...

Page 31: ...6 7 8 9 10 ml Care Cleaning 31 Note Remove the needle from the navel when the cleaning procedure is completed...

Page 32: ...1 2 3 32 Maintenance Repair IO Leg Module After performing IO procedures using fluids clean and repair or replace the IO leg module...

Page 33: ...1 2 3 4 33 Remove and Replace IO Leg Module www laerdal com support How to Videos Maintenance...

Page 34: ...34...

Page 35: ...35...

Page 36: ...al AS P O Box 377 Tanke Svilandsgate 30 4002 Stavanger Norway T 47 51 51 17 00 Printed in Norway 20 13524 Rev E Downloads How ToVideos A FAQ User Guides Local Language Frequently Asked Questions Custo...