ENGLISH 

Directions for Use

www.laerdal.com

MegaCode Kelly

MegaCode Kelly Advanced

Summary of Contents for MegaCode Kelly

Page 1: ...ENGLISH Directions for Use www laerdal com MegaCode Kelly MegaCode Kelly Advanced ...

Page 2: ......

Page 3: ... and Warnings This product contains Natural Rubber latex which may cause allergic reactions when in contact with humans There are electronic components mounted inside the airway head The following techniques should not be performed on this manikin due to the inability to properly sanitize the airway if they are performed Mouth to mouth Mouth to mask ventilation Insertion of simulated vomit for suc...

Page 4: ...ertion Nasopharyngeal airway insertion BagValve Mask Retrograde intubation Lightwand intubation Laryngeal Mask Airway insertion Laryngeal Tube Insertion Combitube insertion Trans Tracheal JetVentilation Surgical cricothyrotomy Needle cricothyrotomy Suctioning techniques Stomach auscultation to verify proper airway positioning Drug Administration IV insertion infusion and bolus into peripheral vein...

Page 5: ...chest during bag valve mask ventilation Pupil Replacement MegaCode Kelly is delivered with a set of pupils containing normal pupils mounted in the head A separate case contains 3 sets of plastic pupil inserts normal constricted and dilated pupils for use in simulating other conditions To change the pupils in the airway head 1 Open the eyelids wide take care not to rip the faceskin 2 Using the suct...

Page 6: ...odine as this will permanently stain the manikin Laerdal Recommends When using a catheter or other venipuncture device spray with lubricant spray for easier insertion Intramuscular Injections Medications can be administered via intramuscular injections bilaterally in the deltoids and thighs and in the gluteal and ventro gluteal locations Laerdal Recommends Medications may be administered via local...

Page 7: ...stopper screw photo 1 and release the BP Arm STEP 2 Take out the arm stopper disconnect the BP cables and remove the BP Arm NOTE Properly store the BP Arm and the attachment accessories for future use To install the Left Arm standard or wound model The manikin includes the necessary arm hardware photo 2 STEP 1 Select the replacement arm remove the deltoid pad STEP 2 Insert the arm adapter photo 3 ...

Page 8: ...chest plate see photo 9 Photo 9 4 Pinch and remove the bladder through the opening between the 2nd and 3rd intercostal spaces on the top side of the hard chest plate See photo10 Photo 10 5 Trim bladder tubing to match original tubing length to fit this manikin style 6 Insert the new pneumothorax bladder into the top side of the chest plate though the 2nd and 3rd intercostal space opening with the ...

Page 9: ...ction pad from upper arm 2 Detach chest skin from tabs at shoulders and back 3 Remove skin to reveal internal portion of upper chest 4 Lift hard chest plate to reveal inside sockets for arm connections 5 Place one washer on threaded 4 bolt 6 Insert threaded bolt through upper arm and through torso so that it is visible in chest cavity Figure 5 Fig 5 7 From inside of chest area slip a washer a spri...

Page 10: ...0470 Belly plate Assembly 380471 Plug Belly plate Adult 380475 Pin Pelvis 380600 Leg Assembly Left Adult 380650 Leg Assembly Right Adult 380700 Arm Male Multi Venous IV Training 381102 Strap Set Head skin 381105 Neck skin Set 6 381107 Teeth Upper 381402 Pad Assembly Deltoid Injection Adult 200 01850 Set Bladder Mid Axillary 200 00250 Tape Crico Thyroid 200 00350 Case Carrying Full Body Adult Manik...

Page 11: ......

Page 12: ... 2012 Laerdal Medical All rights reserved 20 05826 rev B Printed in US ...