Page 1: ...EN www laerdalglobalhealth com MamaNatalie Birthing Simulator User Guide...

Page 2: ......

Page 3: ...the features MamaNatalie gives birth to NeoNatalie a highly realistic newborn simulator that facilitates effective learning of essential newborn care including basic resuscitation measures NeoNatalie...

Page 4: ...oodTank 12 Fill the Catheter 13 Place the Squeaker Unit 13 Protection Against Fluid Spillage 14 Attaching MamaNatalie to the Body 15 Hang the Uterus over the Hook 15 For Cervix Landmark 16 Preparing f...

Page 5: ...Contents 5 Cleaning 25 Textile Parts 25 Hard Parts 25 Blood and Urine 25 NeoNatalie 25 Disassembly Reassembly 26 Specifications 27 Troubleshooting 27...

Page 6: ...6 Items Included MamaNatalie Birthing Simulator inc Uterus Air Bag Reservoir Placenta w Umbilical Cord Fetal Stethoscope Fluid CollectionTray Floor Protector Fluid Drain Cervix Ribbon Backpack...

Page 7: ...Items Included 7 Urine Catheter User Guide Blood Concentrate 2 x Gloves 1 normal and 1 long Syringe 20 ml NeoNatalie Skull w fontanelles NeoNatalie Newborn Simulator...

Page 8: ...rview lit er Abdominal Skin Umbilical Cord Urethra Uterus Bag Uterus Strap Placenta BloodTank Cap Uterus Hook Skeleton BloodTank Uterus Air Reservoirs BloodValve Rectum NeoNatalie Squeaker Unit Waist...

Page 9: ...er Catheterization Delivery of baby Delivery of placenta complete and incomplete Bleeding After Birth Features Realistic Bleeding Bimanual Compression Newborn Airway and Breathing Features Bag MaskVen...

Page 10: ...en the strap over the airways as this will block free air flow and prevent successful ventilations Detach the SimulationTubes The SimulationTubes are attached to the right side of NeoNatalie s chest P...

Page 11: ...11 Preparing for Simulation NeoNatalie Attach and Detach the Umbilical Cord 1 2...

Page 12: ...12 liter l i t e r 0 5 1 Liters 1 2 3 Preparing for Simulation MamaNatalie Fill BloodTank Mix the blood according to manufacturers instructions Maximum 1 5 liters...

Page 13: ...Preparing for Simulation MamaNatalie 13 Maximum 5 ml Fill the Catheter Press the button on the end of the catheter whilst squeezing the syringe Place the Squeaker Unit Press down Fill with water...

Page 14: ...Preparing for Simulation MamaNatalie 14 2 1 Protection Against Fluid Spillage...

Page 15: ...Preparing for Simulation MamaNatalie 15 l i t e r l i t e r Attaching MamaNatalie to the Body Hang the Uterus over the Hook...

Page 16: ...r l i t e r For Cervix Landmark The Cervix Ribbon allows simulating a landmark for the cervix This can be useful for example when training on bimanual compressions Tip Remove the Cervix Ribbon when ce...

Page 17: ...for Simulation Installing Mama U in MamaNatalie 3 5 6 2 4 1 Mama U is a uterus training model for postpartum care designed for training PPIUD and UBT and is compatible for use with MamaNatalie Mama U...

Page 18: ...lace your hands between the Abdominal Skin and the lower part of the Uterus Bag Hold your hands around NeoNatalie s head and clamp the birth opening together Tips for Performing Simulations Pay attent...

Page 19: ...Use MamaNatalie 19 Simulation of Fetal Heart Sounds l i t e r l i t e r Use a finger to tap on the back part of the Skeleton to simulate the desired heart rhythm...

Page 20: ...ater or baby oil before putting NeoNatalie into the Uterus During delivery manipulate NeoNatalie as in a natural birth for example by rotating the baby after the head is delivered Hold NeoNatalie s bo...

Page 21: ...deliver the placenta detach the Placenta from the velcro inside the uterus Retained Placenta Do not detach the Placenta If the learner is pulling the cord hold onto the Placenta to ensure it stays in...

Page 22: ...To open the blood flow push the BloodValve inwards and slide it from the locked position to the middle position If more blood is needed push and slide the BloodValve to the far right position If the...

Page 23: ...with the Uterus Air Reservoir until it is at the appropriate position Before simulation of any uterus condition Ensure that the uterus is unhooked Belly Button With an open hand position the Uterus A...

Page 24: ...ate the cervix landmark tighten the Cervix Ribbon to the desired level see Cervix Landmark section Simulation of Baby Cries Administration of Medications To simulate intramuscular administration of me...

Page 25: ...ed in soapy water to wipe off dirt Blood and Urine Empty the tank after each training session Do not travel with artificial blood stored in the MamaNatalie blood tank Flush the BloodTank with clean wa...

Page 26: ...reverse order Notes When reassembling ensure the urethra is positioned into the small opening of the Uterus before closing the Uterus Strap around the Skeleton When correctly positioned the urethra sh...

Page 27: ...If the BloodTube seems to be blocked a Fill a syringe with water and try to flush the water through the tube from the blood outlet inside the uterus b Inspect the tube from the BloodTank If the tube...

Page 28: ...globalhealth com 20 03048 Rev C 2018 Laerdal Medical AS All rights reserved Manufactured in China for Laerdal Medical AS P O Box 377 Tanke Svilandsgate 30 4002 Stavanger Norway T 47 51 51 17 00 Printe...