LTR-5 INSTRUCTIONS FOR USE

Thank you for having chosen a LAE electronic product. Before installing the instrument, please read these instructions carefully 
to ensure maximum performance and safety.

DESCRIPTION

 

 

 

INDICATIONS

     

 

 

 

     

 

 

 Thermostat output

     

 

 

   
 

     

Fig.1 — Front panel

 Setpoint 

button. 

   

  Increase  button.           

 Decrease 

button. 

   

  Exit / Stand-by button.

INSTALLATION 

  Insert the controller through a hole measuring 71x29 mm.
  Make sure that electrical connections comply with the paragraph “wiring diagrams”. To reduce the effects of electromagnetic 

disturbance, keep the sensor and signal cables well separate from the power wires. 

  Fix the controller to the panel by means of the suitable clips, by pressingly gently;  if fi tted, check that the rubber gasket 

adheres to the panel perfectly, in order to prevent debris and moisture infi ltration to the back of the instrument.

  Place the probe T1 inside the room in a point that truly represents the temperature of the stored product.

OPERATION

DISPLAY

During normal operation, the display shows either  the temperature measured or one of the following indications: 

OFF

Controller in stand-by  

E1

In tuning: timeout1 error 

OR

Probe T1 overrange or failure

E2

In tuning: timeout2 error

TUN / 5.4

Controller in autotuning 

E3

In tuning: overrange error

SETPOINT (display and modifi cation of desired temperature value) 

  press button 

 

for at least half second, to display the setpoint value.

  By keeping button 

 

pressed, use button 

 

or 

 

to set the desired value (adjustment is within the minimum 

SPL

 and the 

maximum 

SPH

 limit).

  When button 

 

is released, the new value is stored.

STAND-BY

Button 

, when pressed for 3 seconds, allows the controller to be put on a standby or output control to be resumed (with  

SB

=YES only). 

CONTROLLER AUTOTUNING IN PID MODE
Before starting 

  Adjust the setpoint 

1SP

 to the desired value.

  Set 

1Y

=PID.

  Make sure that the 

1PB

 value matches the desired control mode (

1PB

<0 for heating; 

1PB

>0 for refrigeration).

Start autotuning 

  Keep buttons 

 

 +  

 

 pressed for 3 seconds. 

1CT

 blinks on the display.

  With   +   

 

  or  

 

 set the cycle time in order to defi ne the dynamic of the process to be controlled. 

  To start autotuning press  

 

 +  

 

 or wait for 30 seconds. To abort the autotuning function, press  

X

.

 

During autotuning 

  During the entire autotuning phase, the display alternates 

 with the actual temperature measured. 

  In case of power failure, when power is resumed, after the initial autotest phase, the controller resumes the autotuning   

function. 

  To abort the autotuning, without modifying the previous control parameters, keep button 

X

 pressed for 3 seconds.

  After the autotuning has taken place successfully, the controller updates the control parameters and start to control.

Errors 

  If the autotuning function failed, the display shows an error code:
  E1 timeout1 error: the controller could not bring the temperature within the proportional band. Increase 

1SP

 in case of 

heating control, vice versa, decrease 

1SP

 in case of refrigerating control and re-start the process.

   E2 timeout2 error: the autotuning has not ended within the maximum time allowed (1000 cycle times). Re-start the autotuning 

process and set a longer cycle time 

1CT

.

  E3 temperature overrange: check that the error was not caused by a probe malfunction, then decrease 

1SP

 in case of heating 

control, vice versa increase 

1SP

 in case of refrigerating control and then re-start the process.

  To eliminate the error indication and return to the normal mode, press button 

X

.

Control improvement

  To reduce overshoot, reduce the integral action reset 

1AR

.

  To increase the response speed of the system, reduce the proportional band 

1PB

. Caution: doing this makes the system less 

stable.

  To reduce swings in steady-state temperature, increase the integral action time 

1IT

; system stability is thus increased, 

although its response speed is decreased.

  To increase the speed of response to the variations in temperature, increase the derivative action time 

1DT

. Caution: a high 

value makes the system sensitive to small variations and it may be a source of instability.

RECALIBRATION

  Have a precision reference thermometer or a calibrator to hand. 
   Ensure that 

OS1

=0 and 

SIM

=0.

   Switch the controller off then on again.
   During the auto-test phase, press buttons 

X

  + 

 

, and keep them pressed till the controller shows 

0AD

.

   With buttons 

 

 and  

 

 select 

0AD 

or 

SAD

0AD

 allows a calibration of 0, inserting a constant correction over the whole 

scale of measurement. 

SAD

 allows a calibration of the top part of the measurement scale with a proportional correction 

between the calibration point and 0. 

   Press    to display the value and then use 

 

 

or 

 

 to make the read value coincide with the value measured by the 

reference instrument. 

   Exit from calibration by pressing button 

X

 .

CONFIGURATION PARAMETERS

  Setup menu is accessed by pressing buttons     + 

X

 for 5 seconds.

   With button 

 

or 

 

select the parameter to be modifi ed.

  Press button  

 

to display the value.

  By keeping button  

 

pressed, use button 

 

or 

 

 to set the desired value.

  When button  

 

is released, the newly programmed value is stored and the following parameter is displayed.

  To exit from the setup, press button 

X

 

or wait for 30 seconds.

PAR

RANGE

DESCRIPTION

SCL

1°C;
2°C;

°F

Readout scale.
1°C : measuring range  

-50/-19.9 … 99.9/150°C for LTR-5T

 

-40/-19.9 … 99.9/125°C for LTR-5C

 

0.0 … 99.9 %r.H.  for LTR-5A

2°C : measuring range  

-50 … 150°C for LTR-5T

 

-40 … 125°C for LTR-5C

 

00 … 99 %r.H.  for LTR-5A

°F : measuring range   

-60 … 300°F for LTR-5T

 

-40 … 250°F for LTR-5C

Caution: upon changing the SCL value, it is then absolutely necessary to re-configure the parameters relevant to the 
absolute and relative temperatures (

SPL

SPH

1SP

1HY

, etc..).

SPL

-50..SPH

Minimum limit for 

1SP 

setting

SPH

SPL.150°

Maximum limit for 

1SP

 setting

1SP

SPL... SPH

Setpoint (value to be maintained in the room).

1Y

HY / PID

Control mode.
With 

1Y

=HY you select control with hysteresis: parameters 

1HY

 and 

1CT

 are used.

With 

1Y

=PID you select a Proportional-Integral-Derivative control mode: parameters 

1PB, 1IT, 1DT, 1AR, 1CT

 will 

be used.

1HY

-19.9…19.9°C Thermostat differential [control with hysteresis].

Set 

1HY

 on a value greater than zero to make the output work in refrigerating mode, vice versa set on a value lower 

than zero to make the output work in heating mode. With 

1HY

= 0 the output is always off.

OFF

ON

1SP

1SP+1HY

T[°]

OFF

ON

1SP

1SP-1HY

T[°]

     Fig. 1a. ON/OFF refrigerating control (

1Y

=HY, 

1HY

>0)                   Fig. 1b. ON/OFF heating control (

1Y

=HY, 

1HY

<0)

1PB

-19.9…19.9°C Proportional band [PID control].

Set 

1PB

 on a value greater than zero to make the output work 

in refrigerating mode, vice versa set on a value lower than 
zero to make the output work in heating mode. With 

1PB

= 0 

the output is always off.

With a proportional controller, the temperature is controlled 
by varying the time of activation of the output. The nearer the 
temperature to set point, the less time of activation. A small 
proportional band increases the promptness of response 
of the system to temperature variations, but tends to make 
it less stable. A purely proportional control stabilises the 
temperature within the proportional band but does not cancel 
the deviation from the set point. 

1IT

0…999s

Integral action time [PID control].

The steady-state error is cancelled by inserting an 
integral action into the control system. The integral action 
time, determines the speed with which the steady-state 
temperature is achieved, but  a high speed (

1IT

 low) may be 

the cause of overshoot and instability in the response. With 

1IT

= 0 the integral control is disabled.

1DT

0…999s

Derivative action time [PID control].

Response overshoot in a system controlled by a Proportional-
Derivative controller may be reduced by inserting a derivative 
action  in  the  control.  A  high  derivative  action  (1

DT

 high) 

makes the system very sensitive to small temperature 
variations and causes instability. With 

1DT

= 0 the derivative 

control is disabled.

1AR

0…100%

Reset of integral action time referred to 

1PB

 [PID control].

Decreasing the parameter 

1AR

 reduces the integral control action zone, and consequently the overshoot (see figure 

on paragraph 

1IT

).

1CT

0…255s

Cycle time. 
In the ON/OFF control (

1Y

=HY), after the output has switched on or off, it will remain in the new state for a minimum 

time of 

1CT 

seconds, regardless of the temperature value.

In the PID control (

1Y

=PID), the cycle time is the period of time in which the output completes a cycle (Time ON + 

Time OFF). The faster the system to be controlled reacts to temperature changes, the smaller the cycle time should 
be, in order to obtain a greater temperature stability and less sensitivity to load variations.

1PF

ON / OFF

Output state in case of probe failure.

BAU

NON / SBY

With 

BAU

=SBY, the stand-by button is enabled.

SIM

0...100

Display slowdown.

OS1

-12.5..12.5°C

Probe T1 offset.

ADR

1...255

LTR-5 address for PC communication.

WIRING DIAGRAMS

TECHNICAL DATA

Power supply

LTR-5…D       

12Vac/dc±10%, 2W

LTR-5…E       

230Vac±10%, 50/60Hz, 2W

LTR-5…U      

 115Vac±10%, 50/60Hz, 2W

Relay outputs (LTR-5..R..)

LTR-5.

S

R..      

OUT1 16(4)A

LTR-5.

Q

R..     

OUT1 12(4)A

SSR drive (LTR-5..F..)

OUT1  

15mA 12Vdc

Inputs

LTR-5A…:  

0-1V

LTR-5C…:  

NTC 10K

Ω

@25°C, part No. LAE SN4...

LTR-5T…:  

PTC 1000

Ω

@25°C, part No. LAE ST1…

Measuring Range

LTR-5A…:     

0…99%r.H.

LTR-5C…:       

-40…125°C

LTR-5T…:       

-50…150°C

Measuring accuracy

LTR-5A…:      

 <±0.7%r.H. in the measuring range

LTR-5C…:      

 <±0.3°C -40…100°C;  ±1°C out of that range

LTR-5T…:      

 <±0.3°C -50…140°C;  ±1°C out of that range

Operating conditions

-10 … +50°C;  

15…80% r.H.

CE (Reference Norms)

EN60730-1; EN60730-2-9;
EN55022 (Class B);
EN50082-1

Front protection

IP55

VIA PADOVA, 25
31046 ODERZO /TV /ITALY
TEL. +39 - 0422 815320
FAX +39 - 0422 814073
www.lae-electronic.com
E-mail: [email protected]

P

AR

TNER VENEZIA • 041 5460713 

6

7

OUT1

12(4)A

2

3

4

9 10 11

rH

V

VIN

V+

V-

TTL

230V~

data I/O

LTR-5AQRE-A

RS485

2

3

4

6

7

OUT1

16(4)A

10

11

230V~

data I/O

LTR-5TSRE-B

1SP

1PB

Temperature

Overshoot

Steady-state error

Process

temperature

Time

1SP

1PB

Temperature

Overshoot

Process

temperature

Time

1PBx1AR%

integral control

action area

1SP

1PB

Temperature

Overshoot

Process

temperature

Time

RS485

6

7

OUT1

S.S.R.

+

-

15m

A

4

12V

3

10

11

230V ~

data I/O

LTR-5CSFE-B

ISTR LTR-5 INGL/TED.indd   1

ISTR LTR-5 INGL/TED.indd   1

11-12-2007   15:45:27

11-12-2007   15:45:27

Reviews: