background image

 

 

  
 

 

 

 

  
 
 
 

Working above 10 metres

. The Microlite  

should be secured with a ratchet strap  
when accessing a roof above 10 metres. 
Wrap the strap around the lower rung  
and the lower back bar of the Microlite.  
Tighten to secure. 
 

                                                                             
 
 
 
 
 
 
    
 
                                                                                        

                                                     

                             

 

 

Fit the Microlite while the 

ladder is on 

the ground. 

 

Feed the ladder

 through the Microlite. 

 

Engage hooks

 over two rungs.  

See 

erection pages 6 and 7 

for the correct 

rung positions. 
  

The 80mm lower hook

 allows the 

Microlite to fit rung pitches from 

250mm to 290mm.  

The position of the 

rung on the hook will vary according to 
the rung pitch. 
 

Engage spring clips

 under the lower 

of the two rungs. Attach with the back 
of the clips facing out to ensure that 
springs do not get knocked off.   
 
 
 
  

 

Fitting  

The  Ladderfix  Microlite  is  a  class  one  ladder  stand  off  suitable  for  use  with  all 
popular patterns of ladder (

except C section ladders) 

which are properly erected 

On firm level ground or with a proper safety base.  

 
 
 
 
 

Important 
 

Spring adjustment 

There 

are two settings

 for the spring assembly. Choose the one that gives 

positive grip with the least tension. 

 

2.  

Position spring here for ladder 

rung pitches 

over 

270mm 

 

1.  Position spring

 

here for ladder 

rung pitches 

under 

270mm 

 
 

Spring Adjustment 

 

Hook 

Summary of Contents for LADDERFIX MICROLITE

Page 1: ...he bottom of the hooks Bomb or drop your ladder see hook inspection page 4 Leave your ladder unattended to get knocked or blown over DO Read instructions Inspect equipment Regularly Adjust springs acc...

Page 2: ...ifications All drawings not to scale B F G Side elevation of hook I 85 mm J 180 mm K 80 mm L 350 mm M 350 mm E K I J L J E H A D C Plan of bottom bar E 640mm F 325mm G 578mm H 630mm M Plan of top bar...

Page 3: ...kets 1 inch x 3 16 inch All aluminium to grade 6063 T4 All welds Argon and Tig welded Springs are galvanised spring steel Test Data 1 HYDRO the makers of the tubing The Mill 2 ALLCO suppliers to Wragg...

Page 4: ...mensions on page 2 2 Both wheels are secure and undamaged and the tyres are clean and not loose swollen or excessively worn 3 Both spring clip assemblies are secure and springs are not stretched 4 No...

Page 5: ...g on the hook will vary according to the rung pitch Engage spring clips under the lower of the two rungs Attach with the back of the clips facing out to ensure that springs do not get knocked off Fitt...

Page 6: ...NG SLOPING ROOF FLAT ROOF AND GUTTERS Walls Hook the Microlite over rungs 1 and 2 of the ladder Extend up end check angle and rest both wheels firmly in position Windows Either Hook the Microlite over...

Page 7: ...at the ladder stiles are touching the lower back bar of the Microlite This ensures the correct working position of the Microlite Gutters When required to access or clean a gutter follow the procedure...

Page 8: ...lter to compensate for poor site conditions Outbuildings and Shallow Angles Do not use ladder at a shallow angle to get to a window above an outbuilding staking a ladder does not prevent ladder stress...

Page 9: ...9 ________________________________________________________________________...