INSTRUCTIONS FOR THE INSTALLER 

11 

 

 

2.  

combustible  material  in  order  to  prevent 
breakage,  deformation,  etc.,  as  a  result  of 
overheating if the material is not designed 
to withstand high temperatures.  

It  must  be  possible  to  clean  the  entire 

flue, no sections being left inaccessible for 
cleaning purposes. 

2.4.2.

 

Chimney crown 

The  upper  end  of  the  chimney  must 

clear  the  roof,  the  roof  ridge  or  any 
obstacle located on the roof by at least 1m. 

 

 

 

Figure No.9 -

 

Distances between chimney 

crown and roof ridge 

The  chimney  crown  must  clear  the 

highest  point  of  any  neighbouring  building 
or obstacle located within a 10m radius of 
the chimney outlet by more than 1m. 

 

Figure No.10 -

 

Distances between the 

chimney crown and objects within a 10m 

radius 

The  chimney  crown  must  clear  any 

neighbouring  building  or  obstacle  located 
within  a  radius  of  10m  to  20m  from  the 
chimney outlet. 

Summary of Contents for AUSTRALIA Verona 1000

Page 1: ...Instruction Book AUSTRALIA Verona 1000 Verona 1001 Verona 1003 ...

Page 2: ...7 2 2 Room for installation 7 2 2 1 Ventilation of the room 7 2 2 2 Location of the appliance in the room 8 2 3 Installation of the appliance 8 2 3 1 Floor 8 2 3 2 Safety distances 8 2 3 3 Checks before lighting for the first time 8 2 3 4 Height adjustment and levelling the appliance 9 2 3 5 Connection to the flue 9 2 3 6 Piping air to the firebox 9 2 4 Chimney flue 10 2 4 1 Type of flue 10 2 4 2 ...

Page 3: ...TION OF THE APPLIANCE 2 1 4 1 5 Firebox glass 18 4 1 6 Air intake registers 18 4 2 Maintenance of the chimney flue 19 4 3 Important advice 19 TROUBLESHOOTING 20 BASIC BREAKDOWNS 21 CERTIFICATE OF COMPLIANCE 22 ...

Page 4: ...G HARDWOOD 60 60 60 PARTICULATE EMISSIONS FACTOR g kg 0 9 0 9 0 9 HIGH BURN Average power high primary air settings kW 15 6 15 6 15 6 Average Peak Power kW 19 9 19 9 19 9 Efficiency high primary air settings 54 54 54 Average dry fuel consumption rate high primary air settings Kg hr 5 5 5 Particulate emission factor oven dry wood high primary air settings g kg 0 7 0 7 0 7 MEDIUM BURN Average power ...

Page 5: ...of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deterioration shorter useful life etc which are not covered by the Lacunza warranty To obtain these data tests have been done on the standards AS NZS 4012 2014 AS NZS 4013 2014 and AS NZS 2918 2018 with eucalyptus wood Figure No 1 Dimensions of the Verona 1000 appliance in...

Page 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Verona 1001 appliance in mm ...

Page 7: ...PRESENTATION OF THE APPLIANCE 6 1 Figure No 3 Dimensions of the Verona 1003 appliance in mm ...

Page 8: ...f the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situated high up in the room at less than 30 cm from the c...

Page 9: ...t AS NZS 2918 2018 3 3 2 A minimum 600mm deep x 1320mm wide x 36mm thick floor protector compressed board should be used in front of each of the appliance doors and be placed centrally in the 1320mm width The Thermal resistivity of the 50mm skamol board floor protector is 0 74m K W The Thermal resistivity of the floor protector is 0 16m K W for 36mm thick compressed board sheets Minimum air gap of...

Page 10: ...ected to the appliance is well secured and there is no chance of it coming free from its housing e g as a result of dilatation due to temperature etc 2 3 6 Piping air to the firebox On this model it is possible to pipe air to the appliance for combustion straight from outdoors We recommend that if possible air be drawn from outdoors for combustion via a non closable pipe with a diameter of 120mm l...

Page 11: ...gth in order to ensure correct operation The flue must prevent the entry of rainwater The flue must be clean and airtight over its entire length The flue must be at least 5m tall and the chimney cap must not hinder the free release of gases If the flue tends to suffer from downdraught then it is necessary to fit an effective anti downdraught cowl a static cowl or a smoke extraction fan or reshape ...

Page 12: ...end of the chimney must clear the roof the roof ridge or any obstacle located on the roof by at least 1m Figure No 9 Distances between chimney crown and roof ridge The chimney crown must clear the highest point of any neighbouring building or obstacle located within a 10m radius of the chimney outlet by more than 1m Figure No 10 Distances between the chimney crown and objects within a 10m radius T...

Page 13: ...INSTRUCTIONS FOR THE INSTALLER 12 2 Figure No 11 Distances between the chimney crown and objects within a radius of between 10 and 20m ...

Page 14: ...stored The logs should have a maximum diameter of 150mm Finely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech hardwood and eucalyptus logs Other fuels Oak chestnut ash maple birch elm etc Resinous wood may mean that the appliance and the flue need to be cleaned more often Non permitted fuels All types of coal and liquid fuel Green wood Green or damp wood ...

Page 15: ...TIONS OF USE 14 3 3 2 Description of the parts of the appliance 3 2 1 Operating components Figure No 13 Operating components on the appliance A Firebox door handle B Air intake o B1 closed left o B2 open right ...

Page 16: ...e has been lit three or four times and has adapted to its flue If it does not disappear then check the flue draught length and diameter of the flue flue insulation airtightness and the humidity of the wood used 3 4 Loading fuel In order to load firewood open the firebox door gently preventing the sudden entry of air to the firebox so that smoke does not enter the room that the appliance is install...

Page 17: ...iance shall be operated with all combustion rate controls adjusted to the minimum setting c Medium burn rate The appliance shall be operated with the register in the middle of its position Lacunza recommends doing medium burn cycles 3 6 Removing ash Following sustained use of the appliance it is necessary to remove the ash from the firebox Remove the ashpit box when cold or using something to prev...

Page 18: ... Figure No 16 Remove the refractory from the right side Figure No 17 Turn the right side refractory as in the picture so that the deflector can fall Figure No 18 Drop the refractory holding it Figure No 19 Remove de deflector ...

Page 19: ...should be kept open However over the hours of use the glass may become dirty To clean it we will use specific degreasing products or dry cleaning products for this task The cleaning should be carried out with the glass cold and taking care not to apply the glass cleaner directly on the glass as if it comes into contact with the door s closing cord it may deteriorate Put the cleaning product on the...

Page 20: ...ire in the chimney close the flue draught close doors and windows remove embers from the firebox block the connection hole with damp cloths and call the fire brigade 4 3 Important advice Lacunza recommends that only Lacunza authorised replacement parts be used Lacunza accepts no liability for any modification to the product which it has not authorised This appliance is a heat producing appliance a...

Page 21: ... continually burn chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temper...

Page 22: ...r junta 2 5045300000 Nickel 1000 DC Cristal puerta hogar 2 5 5040000897 Sylver 800 plus Parrilla fundición 1 6 5044700002 Nickel Manilla puerta hogar 2 7 Cordón plano pelos 8x2mm 2 5 m 8 509020000042 Cordón Negro Ø13mm 2 5 m 9 5044700009 Nickel DC Vermiculita Lateral 340x340x60 mm 2 10 5044700010 Nickel 700 DC Vermiculita Base lateral 210x149x30 mm 4 5044800007 Nickel 800 DC Vermiculita Base later...

Page 23: ...CERTIFICATE OF COMPLIANCE 22 7 CERTIFICATE OF COMPLIANCE ...

Page 24: ...CERTIFICATE OF COMPLIANCE 23 7 ...

Page 25: ...CERTIFICATE OF COMPLIANCE 24 7 ...

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea 5A 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0 ...

Reviews: