INSTRUCTIONS FOR THE INSTALLER
9
2.
•
Make sure that the airtight joints
on the flue circuit are in perfect
condition.
•
Make sure that the doors close
properly.
•
Make sure that all moving parts are
fitted in place.
2.3.4.
Height adjustment and levelling the
appliance
The appliance must be perfectly level,
horizontally and vertically, both at the
front and on the sides (use a spirit level).
The Verona 1000 and Verona 1003
appliances have adjustable legs with which
to adjust its height.
The legs can be adjusted using a 24mm
spanner.
2.3.5.
Connection to the flue
The appliance must be connected to the
chimney flue using special piping designed
to resist the products of combustion (e.g.
stainless steel, enamelled steel, etc.).
To connect the flue to the socket flange,
insert the piping inside the flange and seal
the joint with fire sealant or fire cement to
make it completely airtight.
The installer must ensure that the pipe
connected to the appliance is well secured
and there is no chance of it coming free
from its housing (e.g. as a result of
dilatation due to temperature, etc.).
2.3.6.
Piping air to the firebox
On this model, it is possible to pipe air
to the appliance for combustion straight
from outdoors. We recommend that, if
possible, air be drawn from outdoors for
combustion via a non-closable pipe with a
diameter of 120mm leading to the nozzle
on the bottom-front of the appliance.
If the tube is straight, it can have a
maximum of 12 meters in length. If you use
accessories like elbows, you must subtract
the total length (12 meters) 1 meter for
each accessory used.
This is the best option because it means
that draughts are not created in and
oxygen is not consumed from the room in
which the appliance is fitted. A further
advantage is that there is no danger of
downdraught which may hinder the correct
updraught of the appliance when an
extractor
or
mechanical
ventilation
appliance is used in the same room as the
central-heating appliance or in another one
alongside it.
Figure No.6 -
Conduction of the air intake
for the combustion chamber
Summary of Contents for AUSTRALIA Verona 1000
Page 1: ...Instruction Book AUSTRALIA Verona 1000 Verona 1001 Verona 1003 ...
Page 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Verona 1001 appliance in mm ...
Page 7: ...PRESENTATION OF THE APPLIANCE 6 1 Figure No 3 Dimensions of the Verona 1003 appliance in mm ...
Page 23: ...CERTIFICATE OF COMPLIANCE 22 7 CERTIFICATE OF COMPLIANCE ...
Page 24: ...CERTIFICATE OF COMPLIANCE 23 7 ...
Page 25: ...CERTIFICATE OF COMPLIANCE 24 7 ...
Page 26: ......
Page 27: ......
Page 28: ......