Summary of Contents for Abodi

Page 1: ...Sara Lorea Abodi Andrea Instruction Book ...

Page 2: ... installation 6 2 2 1 Ventilation of the room 6 2 2 2 Location of the appliance in the room 7 2 3 Installation of the appliance 7 2 3 1 Floor 7 2 3 2 Safety distances 7 2 3 3 Checks before lighting for the first time 7 2 3 4 Height adjustment and levelling the appliance 7 2 3 5 Casing 7 2 3 6 Connection to the flue 8 2 3 7 Piping air to other rooms Andrea Abodi 8 2 4 Chimney flue 9 2 4 1 Type of f...

Page 3: ...E 2 1 4 1 2 Inside the appliance 16 4 1 3 Flue socket 16 4 1 4 Firebox glass 16 4 2 Maintenance of the chimney flue 16 4 3 Important advice 16 TROUBLESHOOTING 17 5 BASIC BREAKDOWNS 18 6 DECLARATION OF PERFORMANCE 20 7 CE MARK 24 8 ...

Page 4: ...the legislation applicable in each country and this instruction book 1 1 General characteristics Unit Sara Lorea Abodi Andrea Nominal Heat Output N H O to atmosphere kW 20 19 Efficiency at N H O 80 76 CO emission at 13 O2 at N H O 0 09 0 39 Gas mass flow at N H O g s 15 3 19 Gas temperature downstream of flue socket at N H O ºC 297 400 Optimum flue draught Pa 12 12 Wood consumption beech at N H O ...

Page 5: ...f the fuel fuel loads fuel load frequencies flue draught and system of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deterioration shorter useful life etc which are not covered by the Lacunza warranty Figure No 1 Dimensions of the Sara Lorea appliance in mm ...

Page 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Abodi Andrea appliance in mm ...

Page 7: ...is absolutely crucial to ensure the suitable renewal of the air in the room in which the appliance is fitted The room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situ...

Page 8: ...event breakage deformation etc as a result of overheating if the non combustible material is not designed to withstand high temperatures 2 3 3 Checks before lighting for the first time Make sure that the glass es is are not broken or damaged Make sure that the flueway is not obstructed with packing or loose parts Make sure that the airtight joints on the flue circuit are in perfect condition Make ...

Page 9: ... replacement can be accessed at any time e g counterweight system hydraulic components heating circuit safety components 2 3 6 Connection to the flue The appliance must be connected to the chimney flue using special piping designed to resist the products of combustion e g stainless steel enamelled steel etc To connect the flue to the socket flange insert the piping inside the flange and seal the j...

Page 10: ...rect updraught The diameter of the pipe must be the same as the diameter of the flue socket on the appliance over its entire length in order to ensure correct operation The flue must prevent the entry of rainwater The flue must be clean and airtight over its entire length The flue must be at least 6m tall and the chimney cap must not hinder the free release of gases If the flue tends to suffer fro...

Page 11: ...own must clear the highest point of any neighbouring building or obstacle located within a 10m radius of the chimney outlet by more than 1m Figure No 7 Distances between the chimney crown and objects within a 10m radius The chimney crown must clear any neighbouring building or obstacle located within a radius of 10m to 20m from the chimney outlet Figure No 8 Distances between the chimney crown and...

Page 12: ...mum diameter of 150mm Finely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low density and produce very long flames and may cause the parts of the appliance to wear out more quickly than normal Resinous wood may mean that the appliance and the flue need to be cleaned more often...

Page 13: ... components Figure No 10 Operating components on the appliance A Firebox door handle B Primary air intake o B1 open move right o B2 open move left C Secondary air intake o C1 open move towards the symbol o C2 open move towards the symbol D Double combustion air intake o Opening left door ...

Page 14: ...r when the appliance has been lit three or four times and has adapted to its flue If it does not disappear then check the flue draught length and diameter of the flue flue insulation airtightness and the humidity of the wood used 3 4 Loading fuel In order to load firewood open the firebox door gently both doors at the same time preventing the sudden entry of air to the firebox so that smoke does n...

Page 15: ...f the parts which make up the appliance Do not be alarmed by noises of this kind In order to obtain maximum output open all the air intakes to the firebox and in order to obtain minimum output tend towards closing them For normal use we recommend you close the Primary Intake and leave the Secondary and Double Combustion Intakes open Figure No 11 Operation A Primary air B Secondary air C Double com...

Page 16: ...nd the appliance inside the shell This air can be piped to other rooms IMPORTANT This appliance is not covered by our warranty unless directly connected to the mains electricity supply in accordance with the conditions described in the relevant section in 1 1 Components M 1 x 220V 20W motors T 50ºC ceramic thermostat Electrical diagram Figure No 13 Electrical diagram for fans Use With no fire the ...

Page 17: ...care not to apply the glass cleaner directly onto the glass as it could come into contact with the door seal cord and damage it Also make sure that the cleaning liquid does not enter the moving part of the intake mechanism it may block the mechanism 4 2 Maintenance of the chimney flue VERY IMPORTANT In order to avoid incidents chimney fires etc it is necessary to perform maintenance and cleaning o...

Page 18: ...chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temperature and downdrau...

Page 19: ...BASIC BREAKDOWNS 18 6 BASIC BREAKDOWNS 6 NO TRADUCIR EL TEXTO DE ESTA IMAGEN ...

Page 20: ...000850 500000000850 500000000850 10 Registro entrada aire secundario izquierdo 500000000123 500000000123 500000000123 500000000123 11 Registro entrada aire secundario derecho 500000000122 500000000122 500000000122 500000000122 12 Parrilla hogar 500000000034 500000000034 500000000034 500000000034 13 Cajetín ceniza 504000000029 504000000029 504000000029 504000000029 14 Separador 500000000078 5040600...

Page 21: ...DECLARATION OF PERFORMANCE 20 7 DECLARATION OF PERFORMANCE 7 ...

Page 22: ...DECLARATION OF PERFORMANCE 21 7 ...

Page 23: ...DECLARATION OF PERFORMANCE 22 7 ...

Page 24: ...DECLARATION OF PERFORMANCE 23 7 ...

Page 25: ...CE MARK 24 8 CE MARK 8 ...

Page 26: ......

Page 27: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0 ...

Reviews: