In case of use with a gas other than that for which the
appliance was initially set up, it is
crucial
to replace the
orifices and modify the adjustments as defined below.
TOP BURNERS:
Orifice:
Lift the air ring
E
. Replace the injectors
F
in accordance with
Table 3 and Figure 19 (Ø in 1/100 mm).
The side burner bodies are kept in place by a transversal bar
(
H
, fig. 21). In order to take them out, unscrew screws
I
(fig.
22) then
G
(fig. 20).
Note:
When one or more nozzles are changed, the sealing
ring should be changed as well (see gas circuit diagram).
Adjustment of primary air:
Refit the burner bodies and burner caps in their respective recesses,
adjust the air ring
F
of the burner in accordance with the Table 4
and Figure 19.
Note:
Normal flames are bluish green except for natural gas flames
which are violet.
Wrench 12mm
Fig. 19
F
E
Allen 3mm
Fig. 20
G
I
Fig. 22
Wrench 12mm
H
Fig. 21