General Maintenance
135
4.
Remove the temporary steel tubes installed in Step 7 on page 132.
N
OTE
:
Never spray grease on the floor guides. Abrasive material sticks to the grease and can cause
premature wear.
Figure 3
-
178 Welds on both sides of floor guide
Floor Guides
Floor guides wear out over time, so their replacement is necessary for the packer to continue
operating properly. Usually, replacement of floor guides is done at the same time when sliding shoes
are replaced.
When sliding shoes need to be replaced because of wear, chances are floor guides need replacement
too. To replace floor guides, apply the procedure detailed in the “Replacing Sliding Shoes” section on
page 131. This procedure includes steps to remove and replace floor guides.
Upper Wear Pads
When the packer moves vertically by more than 3⁄16” (checked with a pry bar), the upper wear pads
must be replaced.
FCAW
3-12
3⁄8˝
Summary of Contents for EXPERT
Page 1: ...EXPERT TM MAINTENANCE MANUAL...
Page 2: ......
Page 3: ...EXPERT MAINTENANCE MANUAL...
Page 10: ...viii Table of Contents...
Page 18: ...8 Introduction...
Page 244: ...234 General Maintenance...
Page 251: ...Lubrication 241 Figure 4 11 Glass compartment lubrication chart optional...
Page 252: ...242 Lubrication Figure 4 12 EXPERT lubrication chart...
Page 264: ...254 Lubrication...
Page 320: ...310 Hydraulic System...
Page 357: ...Troubleshooting 349...
Page 358: ...350 Troubleshooting...
Page 386: ...378 Multiplexing...