Labo
★
K
Effects –
www.labo-k-effects.com
–
6
studer 900 p6 interface board part list
Connector X2
Molex 22-27-2101-10
Connector 1
Din 41612
R1, R2
6K81
R3
470R
C1
47
µ
F/63v
All resistors are 1/4w metal film 1%
It is intended to wire an Insert between the channel (pre-EQ) and the output stage.
If this option is not used, the SND and RTN points must be connected using a jumper as
shown below.
connector X2 pinout
1
Mic in Hi
2
Mic in Lo
3
GND
4
GND
5
Line In Lo
6
Line In HI
7
Unbalanced OUT
8
GND
9
NC
10
NC