Voltage Peak Limiter Load vs Power Tables
FP+ Series: Dedicated Touring Amplifiers
FP+ Series amplifiers include the user-definable Voltage Peak Limiter (VPL) function. Rear-panel DIP-switch settings allow the output voltage
to be adjusted and consequently the output power available. The following tables provide information, for the four FP+ Series models, about
resultant output power at typical loads (single channel and bridged operation) with the available VPL settings.
VPL Setting
V peak
Vrms
16
!
8
!
4
!
2
!
195 V
195
138
1200
2400
4800
6500
170 V
170
120
860
1720
3445
6500
140 V
140
99
620
1245
2485
4970
116 V
116
82
445
885
1770
3540
100 V
100
70
320
640
1275
2550
80 V
80
57
230
460
925
1850
66 V
66
47
170
340
665
1330
54 V
54
38
120
240
480
960
VPL Setting
V peak
Vrms
16
!
8
!
4
!
2
!
195 V
390
276
4800
9600
13000
n.r.
170 V
340
240
3445
6890
13000
n.r.
140 V
280
198
2485
4970
9940
n.r.
116 V
232
164
1770
3540
7080
n.r.
100 V
200
142
1275
2550
5100
n.r.
80 V
160
114
925
1850
3700
n.r.
66 V
132
94
665
1330
2665
n.r.
54 V
108
76
480
960
1920
n.r.
Voltage Peak Limiter
Output power bridged per two channels
Load
FP 13000
Voltage Peak Limiter
Output power per channel (W)
Load
VPL Setting
V peak
Vrms
16
!
8
!
4
!
2
!
155 V
155
110
750
1500
3000
3500
121 V
121
86
460
915
1830
3500
101 V
101
70
320
640
1275
2550
83 V
83
59
215
430
860
1720
70 V
70
49
155
305
615
1225
56 V
56
40
100
195
390
785
47 V
47
33
70
140
275
550
38 V
38
27
45
90
180
360
VPL Setting
V peak
Vrms
16
!
8
!
4
!
2
!
155 V
310
220
3000
6000
7000
n.r.
121 V
242
172
1830
3660
7000
n.r.
101 V
202
140
1275
2550
5100
n.r.
83 V
166
118
860
1720
3445
n.r.
70 V
140
98
615
1225
2450
n.r.
56 V
112
80
390
785
1570
n.r.
47 V
94
66
275
550
1105
n.r.
38 V
76
54
180
360
720
n.r.
FP 7000
Voltage Peak Limiter
Output power per channel (W)
Load
Voltage Peak Limiter
Output power bridged per two channels
Load