Lab.gruppen C Series C 10 8X Specifications Download Page 1

C 10:8X

Architect’s and Engineer’s Specifications

C Series: Dedicated Installation Amplifiers

L a b . g r u p p e n   a b  

  S w e d e n

  i n t e r n a t i o n a L   c o n t a c t  

•  

i n f o @ L a b g r u p p e n . c o m       |       u S   c o n t a c t  

•  

i n f o u S @ t c e L e c t r o n i c . c o m

w w w . l a b g r u p p e n . c o m

Overview: Channel Modes and Network 

The  power  amplifier  shall  provide  eight  discrete  channels  of  
amplification. Rear-panel switches shall enable bridging of adjacent 
channels to allow reconfiguration as a 4-, 5-, 6- or 7-channel ampli-
fier.  Each  channel  shall  be  capable  of  independently  driving  either 
low-impedance  or  high-impedance  (70  V/100  V)  loads.  The  output 
circuit topology shall be Class D. The amplifier shall be equipped with 
sensing and communication circuits to allow comprehensive remote 
control and monitoring functions via a separate bridge and network 
controller. The proprietary control and monitoring network shall em-
ploy TCP/IP protocols, use Cat-5 cable for interconnection, and allow 
remote control from an external PC using proprietary software.

Power Output and Performance

Maximum total output of all eight channels shall be 1000 watts. In 
discrete  eight-channel  mode,  each  amplifier  channel  shall  deliver 
maximum  continuous  output  power  as  follows:  125  watts  into  16 
ohms, 125 watts into 8 ohms; 125 watts into 4 ohms; 60 watts into 
2 ohms; or 125 watts into a high impedance (70 Vrms / 100 V peak) 
load. Maximum output voltage per channel shall be 71 Vrms; maxi-
mum output current per channel shall be 5.6 Arms. In bridged mode, 
each  bridged  channel  shall  deliver  maximum  continuous  output 
power as follows: 250 watts into 16 ohms; 250 watts into 8 ohms; 
125 watts into 4 ohms; or 250 watts into a high impedance (140 Vrms 
/ 200 V peak) load.

Default  amplifier  gain  shall  be  32  dB,  with  rear-panel  adjustment 
from  29  -  38  dB  in  3  dB  increments,  selectable  for  each  channel. 
For bridged channels, the amplifier shall automatically compensate 
-6 dB gain internally to maintain consistent output to all channels at 
selected gain.

The  amplifier  shall  exhibit  the  following  performance  parameters 
with  gain  set  at  32  dB  and  VPL  (Voltage  Peak  Limiter)  at  100  V:  
Frequency response shall be 2.3 Hz to 56 kHz (+0/-3 dB at 1 watt 
into an 8 ohm load); channel separation shall be greater than 70 dB; 
and signal-to-noise ratio shall be greater than 112 dBA. THD at 1 watt 
(20 Hz - 20 kHz) shall be less than 0.1%; THD at 1 kHz shall be no 
more than 0.05% at 1 dB below clipping.

A Voltage Peak Limiter shall limit peak output as determined by rear-
panel switches. In discrete eight-channel mode, peak voltage shall 
be selectable in four steps across a range of 100 V to 32 V. In bridged 
mode, peak voltage shall be selectable in four steps from 200 V to 64 
V. The voltage limiter mode shall be selectable for either hard or soft 
limiting characteristics.

Connectors, Controls, and Indicators

The following connectors and controls shall be provided on the REAR- 
PANEL of the amplifier. The input connectors shall be electronically 
balanced, 3-pin Phoenix connectors. The output connectors shall be 
2-pole barrier strip screw connectors. DIP-switches shall determine 
the following: amplifier gain (29 dB to 38 dB in 3 dB increments); fan 
masked;  and  bridged  mode  selection  for  channel  pairs.  Additional 
DIP-switches  shall  determine  Voltage  Peak  Limiter  values  (select-
able per channel), Hard or Soft limiting characteristic, and insertion 
of a 35 Hz high pass filter. Two RJ45 connectors shall be provided for 
input and output of the control and monitoring network signals. 

GPIO (General Purpose Input/Output) functions shall be provided on 
two 2-pole Phoenix connectors and two DIP-switches. GPIO func-
tions shall include power on/off (toggled or same-state) and defeat 
of on/off commands from the network.

The following indicators and controls shall be provided on the FRONT-
PANEL of the amplifier. Eight level control potentiometers, one for 
each channel, shall be provided beneath a front-panel security cover; 
potentiometers shall be detented and provide attenuation from 0 dB 
to infinity in 21 steps. Two separate switches shall be provided for 
power  on/off  and  remote  power  on/off  enabling.  Front-panel  LED 
indicators  shall  display  the  status  of  power  on/off,  NomadLink

® 

network connection, and Power Average Limiter (PAL™). Additional 
LED indicators shall be provided for each channel: signal present and 
high-impedance warning (SIG HI-IMP), Voltage Peak Limiter (VPL), 
Current Peak Limiter (CPL), Very High Frequency (VHF), high tem-
perature warning and fault (TEMP), and MUTE. 
 

Power Supply, Protection, and Cooling 

The power supply shall be a universal type (AC line input between 
100 and 240 VAC at 50 or 60 Hz) with Power Factor Correction and 
a PAL™ (Power Average Limiter) circuit to prevent excessive current 
draw. A soft start circuit shall limit current inrush at power-up to 5 
A. The amplifier shall be cooled by two temperature-controlled, vari-
able-speed fans, with air flow from front-to-back. Adaptive fan on/off 
function shall be dependent on presence of an output signal. 

Physical

The amplifier shall be 483 mm (19 in.) wide, 88 mm (3.5 in / 2 U) 
high, and 343 mm (13.5 in.) deep. The weight shall be 8.5 kg (18.75 
lbs). The chassis shall be black painted steel with a grey painted steel 
front-panel. 

The amplifier shall be approved for use as specified by CE, ANSI/UL, 
ETL and the FCC. The amplifier shall be the Lab.gruppen C 10:8X.

Item no. AES-C108X

Reviews: