LAB-BOX PROFESSIONAL LID User Manual Download Page 1

USER MANUAL

PROFESSIONAL LID

by

lab-box.it/tutorials

Summary of Contents for PROFESSIONAL LID

Page 1: ...USER MANUAL PROFESSIONAL LID by lab box it tutorials...

Page 2: ...5mm and 120 films thanks to the two interchangeable modules and adjustable reels The films are loaded in full daylight and are wound onto the reel using the outer knob without the need to be in a dark...

Page 3: ...3 INDEX User Manual Professional lid parts Parts Assembly Lid inserting Touchpad Recommendations Temperature Time Charts SafetyInformation Compliance 4 5 6 7 8 9 10 11 Index...

Page 4: ...r and digital Thermometer It is a professional alternative to the standard Lab Box lid The Lid has a stainless steel probe that can measure the liquid temperature inside the tank during the process to...

Page 5: ...and tighten the two screws To change the battery re open the slot by unscrewing the two screws AAA Battery PROBE The probe lock holds the temperature probe in the right position throughout the proces...

Page 6: ...6 Contents LID INSERTING VIDEO 1 Insert the probe into the probe slot and close the lid by pushing it towards the tank like the standard lid HOW TO INSERT THE PROFESSIONAL LID...

Page 7: ...timer or the pre sets Play Stop Touch to start or stop the timer 3 Time Pre sets Hold down 3 seconds to save the set time Touch to set quickly the saved time PVC 3m468 5315c black right cut line 7540C...

Page 8: ...hed after about 1 minute Once the temperature stabilises the indication remains accurate within a range of 0 3 0 4 Once the chemicals are inside you cannot change the temperature You can only check th...

Page 9: ...erature and adjust the developing time For C 41 process we highly suggest a pre soak with water pre heating tank and film to reduce temperature drifting Contents TEMPERATURE TIME CHART Time Temperatur...

Page 10: ...e near any heat source or any type of equipment that generates heat including stereo amplifiers Do not use the device near flammable or explosive gases Do not use the device if you notice any unusual...

Page 11: ...te radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfe rence to radio communications However there is no guarantee that interference will...