Page 11

NeoTherm Boilers and Water Heaters

GENERAL CARE

Keep the area around the NeoTherm clear and free from combustible materials, gasoline 

and other flammable vapors and liquids.  Clean the jacket surfaces with a damp cloth 

and mild soap.  Do not use flammable cleaning materials.  Keep the vent terminal free of 

obstructions. do not pile snow against the vent terminal.

ANNUAL INSPECTION AND SERVICE

You should visually inspect the vent pipe once a year. should any corrosion or leaks 

exist, have the affected parts replaced.

Once each year a qualified service agency should conduct a detailed inspection of all flue 

product carrying areas of the boiler and vent system. Follow the service instructions in 

the “installation and operating instructions Manual” for the Laars neotherm.

  Caution

Do  not  use  this  boiler  if  any  part  has  been  under  water. 

Immediately call a qualified service technician to inspect the 

boiler.  Any  part  of  the  control  system  and  any  gas  control 

which has been under water must be replaced.

  WARNING

If  the  unit  overheats  or  the  gas  supply  fails  to  shut  off,  do 

not turn off or disconnect the electrical supply to the pump. 

Instead, shut off the gas supply at a location external to the 

NeoTherm.

En  cas  de  surchauffe  ou  si  l’admission  de  gaz  ne  peut  être 

coupée, ne pas couper ni débrancher l’alimentation électrique 

de  la  pompe.  Fermer  plutôt  le  robinet  d’admission  de  gaz  à 

l’extérieur de l’appareil.

FOR SERVICE

Contact your installing contractor, gas utility, Laars heating systems dealer, or check 

www.laars.com for the nearest authorized representative in your area.

Summary of Contents for NEOTHERM NTH

Page 1: ...oxide gas in flue gases which could cause serious injury property damage or death Improper installation and or operation will void the warranty AVERTISSEMENT Assurez vous de bien suivres les instructi...

Page 2: ...LAARS Heating Systems...

Page 3: ...Restarting the NeoTherm 5 In the Event of Power Failure 5 THE USER INTERFACE AND ON OFF SWITCH 6 About Lockouts Holds and Alerts 10 Care Inspection and Service 11 Shown without jacket Internal compone...

Page 4: ...s supplier call the fire department POUR VOTRE S CURIT LISEZ AVANT DE METTRE EN MARCHE AVERTISSEMENT Quiconque ne respecte pas la lettre les instructions dans la pr sente notice risque un d but d ince...

Page 5: ...y information listed above If you don t smell gas go to the next step 8 Slowly turn the manual gas valve to ON The handle on the valve will be parallel to the gas pipe 9 Replace the front panel 10 Tur...

Page 6: ...a prochaine tape 8 Remettez lentement la soupape d arr t de gaz en position ON La poign e sera parall le au tuyau de gaz 9 Replacez le couvercle avant 10 R tablissez l alimentation lectrique l apparei...

Page 7: ...h 3 5 If after three attempts the unit still does not light shut down the boiler and call your service technician If the unit has been drained follow these steps 1 See the Installation and Operation M...

Page 8: ...e HMI is used to send commands to the boiler controller and to display operating and setup information sent from the boiler controller The drawing below shows the main parts of the user interface HMI...

Page 9: ...reen Button Home Screen The Home Screen has three sections The upper section of this screen shows the most important operating information In this example the display is showing the system setpoint th...

Page 10: ...k or change the most common settings on the unit Login If you want to change a setup value or function and the system requires a password you can enter it here Test These parameters let you turn the b...

Page 11: ...e the most common settings used in a typical installation Quick Start Menu Example Changing the CH Central Heat Setpoint Changing the CH Setpoint On the Quick Start menu use the Up and Down Arrows to...

Page 12: ...period of time before locking out This allows the controller to see if the error becomes resolved prior to the hard lockout An alert indicates that some feature of the control system s operation was n...

Page 13: ...structions in the Installation and Operating Instructions Manual for the Laars NeoTherm Caution Do not use this boiler if any part has been under water Immediately call a qualified service technician...

Page 14: ...mer Service Service Advisors 20 Industrial Way Rochester NH 03867 603 335 6300 Fax 603 335 3355 Applications Engineering 1869 Sismet Road Mississauga Ontario Canada L4W 1W8 905 238 0100 Fax 905 366 01...

Reviews: