Page 34
4.10
Gas Supply Pressure
4.11 Gas Adjustment
The minimum and maximum inlet gas line pressures must be
LP Gas
Natural Gas
Maximum Pressure
13.0" WC
Maximum Pressure
10.5" WC
Minimum Pressure
8.0" WC
Minimum Pressure
3.5" WC
Inlet Gas Pressure Port
FTCF140
FTCF199
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
Loosen the pressure port bolts before you check the gas inlet pressure.
CAUTION
The appliance and its individual shutoff valve must be disconnected from the
gas supply piping system during any pressure testing of the system at test
pressures in excess of 1/2 psi (3.5 kPa).
1. Turn ON the GAS and WATER supply to the FT.
2. Remove water heater cover by loosening the 4 screws
that hold the cover in place.
3. Turn ON the FT.
4. Ensure your Mascot FT is set for the correct altitude.
The default setting is for altitudes of 0~1,999 ft above
sea level. If your Mascot FT is installed at an altitude of
2,000 ft,or greater the correct altitude setting should be
set according to Section 4.12 of the Mascot FT Install
and Operating Manual before continuing with tuning.
WARNING
This conversion shall be installed by a qualifi ed service
agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority
having jurisdiction. If the information in these instructions
is not followed exactly, a fi re, an explosion or production
of carbon monoxide may result causing property damage,
personal injury or loss of life. The qualifi ed service agency is
responsible for the proper and complete installation of this kit.
The installation is not proper and complete until the operation
of the converted appliance is checked as specifi ed in the
manufacturer's instruction supplied with the kit.
AVERTISSEMENT
Ce conversion doit être installé par un organisme de service
conformément aux instructions du fabricant et tous les
codes et les exigences de l’autorité compétente. Si les
informations contenues dans ces instructions n’est pas suivi
à la lettre, un incendie, une explosion ou de la production de
monoxyde de carbone mais résultat causant des dommages
matériels, des blessures ou des pertes de vie. Le service est
responsable pour la bonne et complète l’installation de ce kit.
L’installation n’est pas correcte et complète jusqu’à ce que
le fonctionnement de l’appareil converti est vérifi ée comme
spécifi é dans le manuel d’instruction fourni avec le kit.
800.900.9276
•
Fax 800.559.1583
(Customer Service, Service Advisors)
20 Industrial Way, Rochester, NH 03867
•
603.335.6300
•
Fax 603.335.3355
(Applications Engineering)
1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8
•
905.238.0100
•
Fax 905.366.0130
www.Laars.com
Document 4290C
The FT Series, Floor-Standing, Gas Conversion Kit
pg 1 of 4
Steps 1 thru 26
The FT Series, fl oor standing, condensing boiler is confi gured
for Natural Gas (NG) from the factory.
A Natural Gas to Propane
Conversion Kit is included with every FT. The gas conversion kit will
show you how to convert your FT boiler to propane gas. If your FT
does not have the bag containing the conversion kit, a replacement kit can be
obtained. Contact the manufacturer and request a replacement conversion kit.
NOTICE
If your installation altitude is greater than 2000 ft, please check that the ‘High Altitude’
Installer Setting has been adjusted to suit your installation altitude.
CAUTION
This combination boiler has already been set to burn natural gas,
but can be converted to burn LP gas. Before placing the combination
boiler into operation, verify that your fuel source is natural gas. Or
verify that your fuel source is propane if you are converting this
combination unit to propane.
Kit # R20771
Top Access Panel
Front Panel Knob
Front Panel
Figure A
ON / OFF
To convert from Natural Gas to Propane Gas
1.
Turn
OFF
the FT.
The
ON / OFF
button is
located at the bottom left of the Control Display.
2.
Turn
OFF
the
GAS
and
WATER
supply to the
FT (valves are located on the plumbing pipes.)
H2373900B
H2373900C
Gas Conversion Part Numbers
Natural Gas
(NG) Part #
Propane Gas
(LP) Part #
FTCF140
FT1412N5
FT1412P5
FTCF199
FT1780
FT1802
Nozzle
Orifi ce