background image

 

 

S1 Vivaldi II Owner’s Manual 

Page 3 

 

Label  Function 

Label  Function 

Label  Function  Label  Function 

Drip Tray 

Cup Warming 

Tray 

15 

92

C Lamp 

22 

On/Standby 

Lamp 

Steam Arm 

Control Panel 

16 

93

C Lamp 

23 

Hot Water 

Button 

Rubber Feet 

10 

Group 

17 

94

C Lamp 

24 

Single Cup 

Button 

Steam/Group 

Pressure Gauge 

11 

Portafilter 

Handle 

18 

95

C Lamp 

25 

Double Cup 

Button 

Side Panels 

12 

Drip Tray Grate 

19 

96

C Lamp 

26 

Boiler Button 

Steam Knob 

13 

Boiler Lamp 

20 

97

C Lamp 

27 

On/Off Button 

Splash Panel 

14 

91

C Lamp 

21 

ECON 

Lamp 

28 

Hot Water 

Outlet 

 

3  Document Scope – Caveats and Clarifications 

This manual includes material that both duplicates and enhances the official LaSpaziale 

S1 Vivaldi II Instruction Manual in key areas. However, it does not duplicate the detailed 

and very important information covering machine certifications or ratings nor does it 

repeat all the warning and safety information contained on the “lawyer” pages.  That 

information, as contained in LaSpaziale Instruction Manual, is considered included in 

this document by reference. 
This document solely covers the S1 Vivaldi II plus options available and supported by 

Chris Coffee Service and/or other vendors supplied by Chris Coffee Service through its 

exclusive distribution agreements with La Spaziale S.p.A. 

4  Basic Machine Operation 

(

BOLD 

= lamps, 

Reverse 

= buttons, numbers in parentheses reference to above table) 

4.1  15A or 20 Amp Operation 

Please read this section first, especially if you purchased the 20A version of the 
LaSpaziale VII but do not currently have an available 20A outlet. 

The LaSpaziale VII is available in 15A and 20A versions. In actuality, they are both 

identical machines.  There is an internal switch that selects the operating mode and 

they have different power cords installed.  The power cord is the easiest way to tell 

which version you have.  The 15A VII has a standard 3-prong AC plug with two parallel 

blades and a round ground pin.  The 20A VII has a 3-prong plug with two perpendicular 

blades and a round ground pin.  The 20A version therefore requires a 20A circuit which 

has a special 20A outlet which accepts the 20A plug.  
Most modern kitchens have 20A circuits.  However, they often do not use 20A outlets 

because multiple outlets may be on the same 20A circuit.  If you have a 20A circuit with 

a 20A outlet this most likely means that outlet has its own dedicated 20A circuit and is 

safe to use with the VII.  A 20A circuit with normal 15A outlets probably means that 

Summary of Contents for S1 Vivaldi II

Page 1: ...aldi II Double Boiler Espresso Machine Owner s Manual Rev D Covers VII s with and w o Enhanced Temperature Offset and Programmable Preinfusion Updated on 5 30 10 to clarify that Extreme Temp Mode sett...

Page 2: ...e Preinfusion 14 5 Alarm Handling 15 5 1 Coffee Group Water Dosing System Failure 15 5 2 Coffee Group Temperature Detection System Failure 15 5 3 Steam Boiler Temperature Detection System Failure 16 5...

Page 3: ...usion Electronic Boiler Refill Built in Safety Thermostat Semi Automatic Hot Water Delivery Manual Steam Valve Fault Diagnosis Alarms Combined Boiler and Group Pressure Gauge Two Complete Portafilter...

Page 4: ...S1 Vivaldi II Owner s Manual Page 2 2 Reference Photos These numbered photos will be referenced throughout the document i e 13 FIGURE 1 Indicator Lights and Control Buttons...

Page 5: ...rted by Chris Coffee Service and or other vendors supplied by Chris Coffee Service through its exclusive distribution agreements with La Spaziale S p A 4 Basic Machine Operation BOLD lamps Reverse but...

Page 6: ...vers from the machine and flipping the internal mode switch This is called ECONOMY mode and is described later in this manual As a temporary solution Economy mode is a great option for those that real...

Page 7: ...wn with the same screwdriver you used to remove the cup warming tray and flip the switch to the desired position 4 2 Initial InstallationBeforeConnectingPower After removing the VII from its packing c...

Page 8: ...e if the solution isn t obvious Also your VII dealer may request that you check that your water hardness is below a certain level to ensure long life and trouble free operation Hardness test strips ma...

Page 9: ...eating phase until the set temperature is reached 9 The machine is now ready WARNING To activate and deactivate the boiler mode press the BOILER 26 button Every time you turn on the machine the boiler...

Page 10: ...starts and the lights 14 15 16 turn on to show that the one shot espresso dose is being programmed 5 When the coffee inside the cup has reached the desired quantity again press the button 24 to stop...

Page 11: ...ols which is on according to demand with preference going to the group boiler This is useful for those owning the 20A model but lacking a 20A circuit 4 Turning the Steam Hot Water Boiler On and Off 1...

Page 12: ...10 1 Standard Temperature Adjustment 1 When the machine is On ON STBY solid green press the button ON OFF 27 and keep it pressed for 3 seconds the control light 22 and the one concerning the set tempe...

Page 13: ...offset mode and then following instructions in paragraph 4 10 2 To Which Machines Do These Instructions Apply Instructions are given in the two sections below both This first is for machines with the...

Page 14: ...C is designated by all temperature lamps off A 8 C offset is designated by all temperature lamps plus ECON on If your positive offset is more than you wish each press of the Double Cup button changes...

Page 15: ...Off Off Off Off Off 4 C On On On On Off Off Off Off 5 C On On On On On Off Off Off 6 C On On On On On On Off Off 7 C On On On On On On On Off 8 C On On On On On On On On 4 10 3 Extreme Temperature Set...

Page 16: ...pressed lights 96 C 19 97 C 20 and Econ 21 will switch on in succession Each light indicates a 1 C increase All three lights on 100 C If you start with the master temperature set to 91 C each time tha...

Page 17: ...uses computerized sensors to robustly handle VII device malfunctions There are two types of alarms the VII can generate Blocking Alarms these are the most serious The VII will turn itself Off and dis...

Page 18: ...is a blocking one and occurs when the boiler triac always remains in conduction temperature 140 C The lights 19 20 21 are flashing Turn off the VII and request service 5 6 Boiler Automatic Refill Syst...

Page 19: ...S1 Vivaldi II Owner s Manual Page 17 6 Connection Diagrams 6 1 Electrical Connection Diagram...

Page 20: ...Vivaldi II Owner s Manual Page 18 6 2 Control BoardConnection Diagram 6 3 Triac Board ConnectionDiagram BOILER TRIAC BD GROUP TRIAC BD Cooling Fan is below this board and runs only when boiler is heat...

Page 21: ...nnection control board on control panel F Flow meter F1 in Phase inlet into the triac that feeds the boiler heating element F2 out Phase outlet from the triac that feeds the boiler heating element F2...

Page 22: ...1 Vivaldi II Owner s Manual Page 20 7 VII Water Flow Diagram The information below is provided strictly as a reference for VII owners who are curious about the function of their VII Dual Boiler design...

Page 23: ...icles This is why the long handled brush to keep your hands away from hot water Also give the dispersion disk a quick scrub Reassemble using the other set of screens Soak the original set of screens i...

Page 24: ...way valve Remove the backflush disk make shot of espresso and throw it out Important Tip To maximize the effectiveness of the cleaning process and minimize how often a detergent cleaning is required...

Page 25: ...designated by the letters A and B in the diagram below First loosen the lock nut A 14mm wrench Press the Single Cup 24 or Double Cup 25 button and wait for the group pressure gauge D to stabilize Mos...

Page 26: ...f this valve until the valve just opens when running the pump as the pressure reaches 12 5 bar 4 If water is pouring out of tube below C before the pressure hits 12 5 bar use the 21mm socket to tighte...

Page 27: ...the integrated programmable preinfusion However this option can still be installed if preferred or if the user has a V1 or earlier V2 version that lacks the programmable preinfusion Click the link be...

Page 28: ...S1 Vivaldi II Owner s Manual Page 26 Longer Steam Arm Shown next to stock arm...

Page 29: ...ons on all coffee topics http www coffeegeek com Here you will find lively debate on all things coffee and VII information including reviews by owners http www s1cafe com s1v2 Website devoted solely t...

Page 30: ...S1 Vivaldi II Owner s Manual Page 28 11 Quick Setting Guide...