Note that the method below only works if the master temperature is set to either 

91ºC or 97ºC.  If the temperature is set to 91ºC you can only use the instructions 

below to lower the temperature by 1ºC, 2ºC, or 3ºC.  If the temperature is set to 

97ºC you can only use the instructions below to raise the temperature by 1ºC, 2ºC, 

or 3ºC. Consequently you must use the instructions provided in section 4.10.1 to 

set the master temperature to 91ºC or 97ºC BEFORE using the instructions below. 

If this is not done, the instructions below for entering the Extreme Temperature 

Set mode will work as described, but once in that mode attempting to a raise or 

lower the temperature has no effect. 

Instructions for programming this mode AFTER setting the master temperature to 91ºC 

or 97ºC are: 

  Start with the machine in Standby mode (

ON/STBY

 light flashing). 

  Press and hold the 

Two Cup

 button for ~3 seconds until lights 94

º

C (17) and 

95

º

C(18) come on indicating that the Extreme Temperature Function setting 

mode is active. 

  If you start with the master temperature set to 97

º

C

each time that the 

Hot 

Water

 button is pressed, lights 96ºC

 (

19), 97ºC

 (

20), and Econ (21) will switch on 

in succession. Each light indicates a 1ºC increase. All three lights on = 100ºC. 

  If you start with the master temperature set to 91

º

C

each time that the 

One Cup

 

button is pressed, lights 93ºC

 (

16), 92ºC

 (

15), and 91ºC (14) will switch on in 

succession. Each light indicates a 1ºC decrease. All three lights on = 88ºC. 

  Press the 

Two Cup

 button again to exit Extreme Temperature set mode and 

return back to Standby mode 

Note:   

When you change the temperature of the 91ºC and/or 97ºC buttons 
according to the above instructions, the change only remains in effect until 
the temperature is changed. For example, if you change the 91ºC selection 
by 3ºC to yield 88 ºC, then later change the temperature to 93C, the next 
time you select  91ºC,  you will get 91ºC, not 88 ºC. If you wish to obtain 
88ºC again you will need to follow the above instructions to reprogram in 
the 3 ºC decrease. 

4.11 Programmable Preinfusion 

Note:  only machines purchased or upgraded after 7/1/08 have this feature. 
With the machine on (

ON/STBY

 (22) lit and not blinking), press and hold the 

ON/OFF

 

button(27) for three seconds until the 

ON/STBY

 (22) and the current preset temperature 

lamps are both blinking. Then press the 

BOILER

 

button (13) for 3 seconds.  The 

temperature plus 

ECON

 lamps now display the current time delay between when the 

Summary of Contents for S1 Vivaldi II

Page 1: ...aldi II Double Boiler Espresso Machine Owner s Manual Rev D Covers VII s with and w o Enhanced Temperature Offset and Programmable Preinfusion Updated on 5 30 10 to clarify that Extreme Temp Mode sett...

Page 2: ...e Preinfusion 14 5 Alarm Handling 15 5 1 Coffee Group Water Dosing System Failure 15 5 2 Coffee Group Temperature Detection System Failure 15 5 3 Steam Boiler Temperature Detection System Failure 16 5...

Page 3: ...usion Electronic Boiler Refill Built in Safety Thermostat Semi Automatic Hot Water Delivery Manual Steam Valve Fault Diagnosis Alarms Combined Boiler and Group Pressure Gauge Two Complete Portafilter...

Page 4: ...S1 Vivaldi II Owner s Manual Page 2 2 Reference Photos These numbered photos will be referenced throughout the document i e 13 FIGURE 1 Indicator Lights and Control Buttons...

Page 5: ...rted by Chris Coffee Service and or other vendors supplied by Chris Coffee Service through its exclusive distribution agreements with La Spaziale S p A 4 Basic Machine Operation BOLD lamps Reverse but...

Page 6: ...vers from the machine and flipping the internal mode switch This is called ECONOMY mode and is described later in this manual As a temporary solution Economy mode is a great option for those that real...

Page 7: ...wn with the same screwdriver you used to remove the cup warming tray and flip the switch to the desired position 4 2 Initial InstallationBeforeConnectingPower After removing the VII from its packing c...

Page 8: ...e if the solution isn t obvious Also your VII dealer may request that you check that your water hardness is below a certain level to ensure long life and trouble free operation Hardness test strips ma...

Page 9: ...eating phase until the set temperature is reached 9 The machine is now ready WARNING To activate and deactivate the boiler mode press the BOILER 26 button Every time you turn on the machine the boiler...

Page 10: ...starts and the lights 14 15 16 turn on to show that the one shot espresso dose is being programmed 5 When the coffee inside the cup has reached the desired quantity again press the button 24 to stop...

Page 11: ...ols which is on according to demand with preference going to the group boiler This is useful for those owning the 20A model but lacking a 20A circuit 4 Turning the Steam Hot Water Boiler On and Off 1...

Page 12: ...10 1 Standard Temperature Adjustment 1 When the machine is On ON STBY solid green press the button ON OFF 27 and keep it pressed for 3 seconds the control light 22 and the one concerning the set tempe...

Page 13: ...offset mode and then following instructions in paragraph 4 10 2 To Which Machines Do These Instructions Apply Instructions are given in the two sections below both This first is for machines with the...

Page 14: ...C is designated by all temperature lamps off A 8 C offset is designated by all temperature lamps plus ECON on If your positive offset is more than you wish each press of the Double Cup button changes...

Page 15: ...Off Off Off Off Off 4 C On On On On Off Off Off Off 5 C On On On On On Off Off Off 6 C On On On On On On Off Off 7 C On On On On On On On Off 8 C On On On On On On On On 4 10 3 Extreme Temperature Set...

Page 16: ...pressed lights 96 C 19 97 C 20 and Econ 21 will switch on in succession Each light indicates a 1 C increase All three lights on 100 C If you start with the master temperature set to 91 C each time tha...

Page 17: ...uses computerized sensors to robustly handle VII device malfunctions There are two types of alarms the VII can generate Blocking Alarms these are the most serious The VII will turn itself Off and dis...

Page 18: ...is a blocking one and occurs when the boiler triac always remains in conduction temperature 140 C The lights 19 20 21 are flashing Turn off the VII and request service 5 6 Boiler Automatic Refill Syst...

Page 19: ...S1 Vivaldi II Owner s Manual Page 17 6 Connection Diagrams 6 1 Electrical Connection Diagram...

Page 20: ...Vivaldi II Owner s Manual Page 18 6 2 Control BoardConnection Diagram 6 3 Triac Board ConnectionDiagram BOILER TRIAC BD GROUP TRIAC BD Cooling Fan is below this board and runs only when boiler is heat...

Page 21: ...nnection control board on control panel F Flow meter F1 in Phase inlet into the triac that feeds the boiler heating element F2 out Phase outlet from the triac that feeds the boiler heating element F2...

Page 22: ...1 Vivaldi II Owner s Manual Page 20 7 VII Water Flow Diagram The information below is provided strictly as a reference for VII owners who are curious about the function of their VII Dual Boiler design...

Page 23: ...icles This is why the long handled brush to keep your hands away from hot water Also give the dispersion disk a quick scrub Reassemble using the other set of screens Soak the original set of screens i...

Page 24: ...way valve Remove the backflush disk make shot of espresso and throw it out Important Tip To maximize the effectiveness of the cleaning process and minimize how often a detergent cleaning is required...

Page 25: ...designated by the letters A and B in the diagram below First loosen the lock nut A 14mm wrench Press the Single Cup 24 or Double Cup 25 button and wait for the group pressure gauge D to stabilize Mos...

Page 26: ...f this valve until the valve just opens when running the pump as the pressure reaches 12 5 bar 4 If water is pouring out of tube below C before the pressure hits 12 5 bar use the 21mm socket to tighte...

Page 27: ...the integrated programmable preinfusion However this option can still be installed if preferred or if the user has a V1 or earlier V2 version that lacks the programmable preinfusion Click the link be...

Page 28: ...S1 Vivaldi II Owner s Manual Page 26 Longer Steam Arm Shown next to stock arm...

Page 29: ...ons on all coffee topics http www coffeegeek com Here you will find lively debate on all things coffee and VII information including reviews by owners http www s1cafe com s1v2 Website devoted solely t...

Page 30: ...S1 Vivaldi II Owner s Manual Page 28 11 Quick Setting Guide...

Reviews: