week, if so desired. Each new machine has the cable needed to plug this timer into
cable tied into place just behind the front panel. More information including the
installation manual can be found here:
http://s1cafe.com/s1v2/images/Vivaldi%20Timer%20Instructions.pdf
There is a switch labeled ON / OFF on top of the controller box adjacent to the 15A/20A
switch . This switch must be set to OFF if you do not have the Timer plugged in and it
must be set to ON when the timer is installed. Also, the state of this switch is only
sensed when the power cable is unplugged, then plugged back in. So if you need to
change this switch you will need to unplug the machine for at least 5 seconds after you
do so.
WARNING: If you do NOT have the Timer installed but you have the switch set to ON,
the pump will not come on when you try to pull a shot.
4.3 Initial Installation Before Connecting Power
After removing the Mini VII from its packing carton and setting it on the counter, check
for additional installation instructions that may be included. You should also have all the
accessories shown in the photo below plus a rubber backflush disk (not shown).
Tip the Mini VII on its side. Twist all four rubber feet (3) hand tight as they may vibrate
loose during shipping. While performing that task, use a screwdriver to ensure that the
four screws on the bottom (two on each side between the rubber feet) which fasten the
two side panels (5) to the chassis bottom are tight. These steps will help ensure the
quietest possible operation of your Mini VII.
Important Tip: Your Mini VII dealer may request that you check that your water
hardness is below a certain level to ensure long life and trouble free operation.
Hardness test strips may be included for this purpose. If your water fails this