5.6 Damaged Boiler Heating Element Triac SSR
(only with the boiler
turned on)
This alarm is a blocking one, and occurs when the boiler triac always remains in
conduction (temperature >140°C). The lights 19-20-21 are flashing.
Turn off the Mini V2 and request service. Note: new machines use a dual Solid State
Relay (SSR) rather than the triac.
5.7 Boiler Automatic Refill System Failure
(only with the boiler
turned on)
This is a blocking alarm which is signaled by blinking of the
Boiler
(13) light. If the pump
runs for more than 1 minute attempted to refill the boiler without the controller circuit
receiving a boiler full signal, this alarm is triggered.
This alarm can be temporarily cancelled by pressing the
BOILER
(26) button to turn off
the boiler. The Mini VII can be operated with the steam boiler off until repairs to the
boiler function occur.