La Crosse WS9008UIT Instruction Manual Download Page 1

 

1

TEMPERATURE STATION 

Model WS9008UIT 

Instruction Manual 

 
INTRODUCTION: 

Congratulations on purchasing this innovative 915MHz Temperature 
Station which displays indoor and outdoor temperature. To enjoy the full 
benefits of this innovative product, please read this operating manual. 

 
 
 
 
 
 

 

« Instant Trans» is the up and coming state-of-the-art new 
wireless transmission technology, exclusively designed and developed 
by LA CROSSE TECHNOLOGY.  
“IT +” offers you an immediate update of all your outdoor data measured 
from the transmitters: follow your climatic variations in real-time!

Summary of Contents for WS9008UIT

Page 1: ...ature To enjoy the full benefits of this innovative product please read this operating manual Instant Transmission is the up and coming state of the art new wireless transmission technology exclusivel...

Page 2: ...ture Station Temperature display in degrees Celsius C or Fahrenheit F selectable Indoor and Outdoor temperature display with MIN MAX recording Function Keys Foldout Stand Battery Compartment Cover LCD...

Page 3: ...at 915 MHz Outdoor signal reception intervals at every 27 5 seconds Table standing or wall mounting The Outdoor Temperature Transmitter Remote transmission of outdoor temperature to Temperature Stati...

Page 4: ...splayed after 60 seconds remove the batteries and wait for at least 10 seconds before reinserting them 3 After inserting the batteries into the transmitter the Temperature Station will start receiving...

Page 5: ...below 1 Remove the cover at the back of the weather station 2 Insert batteries observing the correct polarity see marking 3 Replace compartment cover INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE T...

Page 6: ...res This is because a random security code is assigned by the transmitter at start up and this code must be received and stored by the Temperature station in the first 3 minutes of power being supplie...

Page 7: ...rature display Press and hold to toggle between the temperature display of degree Celsius C and Fahrenheit F MIN MAX key To toggle between the MIN MAX indoor and outdoor temperature display Press and...

Page 8: ...outdoor temperature records to the current outdoor temperature if the outdoor temperature is displayed LCD SCREEN AND SETTINGS Temperature display in C or F Receiver low battery Outdoor signal recept...

Page 9: ...tion was successful icon on or not icon off DISPLAY OF INDOOR TEMPERATURE READING AND INDOOR MIN MAX RECORDS 1 Press the IN OUT key to view the current indoor temperature 2 Press the MIN MAX key to vi...

Page 10: ...OUT key to view the current outdoor temperature 2 Press the MIN MAX key to view the MIN record 3 Press again the MIN MAX key to view the MAX record 4 Press the MIN MAX once more to return to current o...

Page 11: ...to be reset separately CHANGING THE TEMPERATURE DISPLAY UNIT The default temperature display unit is C To change the temperature display unit to F user should press and hold the IN OUT key for about 2...

Page 12: ...ng on the 915MHz signal frequency can also cause interference Note When the 915MHz signal is received correctly do not re open the battery cover of either the transmitter or Temperature Station as the...

Page 13: ...utdoor temperature values can be received from the desired locations 1 Fix a screw not supplied into the desired wall leaving the head extended out by about 5mm 2 Remove the stand from the Temperature...

Page 14: ...nsmitter To wall mount 1 Secure the bracket onto a desired wall using the screws and plastic anchors 2 Clip the remote temperature transmitter onto the bracket Note Before permanently fixing the trans...

Page 15: ...only with new batteries of the recommended type When cleaning the display and casings use a soft damp cloth only Do not use solvents or scouring agents as they may mark the LCD and casings Do not subm...

Page 16: ...splay range in C 9 9 C to 59 9 C Display range in F 14 2 F to 99 9 F due to LCD display limitation Outdoor 39 9 C to 59 9 C with 0 1 C resolution 39 8 F to 140 F with 0 2 F resolution OF L displayed i...

Page 17: ...terial should be deposited at relevant recyclable waste collection points As stated on the packaging and labelled on the product reading the User manual is highly recommended for the benefit of the us...

Page 18: ...18 Distributed by Sontax Australia Phone 1800 653 238 Email sales sontax com au Website www sontax com au WS9008UIT Printed in China...

Reviews: