1
WS-9002U
Wireless 433 MHz
Temperature Station
Instruction Manual
Page 1: ...1 WS 9002U Wireless 433 MHz Temperature Station Instruction Manual ...
Page 2: ...up Guide Battery Installation 7 8 Features Minimum and Maximum Temperatures 9 Resetting Minimum and Maximum Temperatures 9 Additional remote temperature sensors optional 10 12 Mounting 12 14 Troubleshooting 14 16 Maintenance and Care 16 Specifications 17 18 Warranty Information 19 23 ...
Page 3: ...ture sensor TX6U and mounting bracket Figure 2 3 3 each 1 2 Philips screws 4 One strip of double sided adhesive tape 5 Instruction Manual and Warranty Card ADDITIONAL EQUIPMENT not included 1 1 Philips screwdriver 2 2 Fresh AAA 1 5V batteries 3 2 Fresh AA 1 5V batteries Figure 2 Figure 1 ...
Page 4: ... remote temperature sensor 3 to 5 feet apart 2 Batteries should be out of both units for 10 minutes 3 Place the batteries into the remote temperature sensor first then into the indoor temperature station All remote temperature sensors must be started before the indoor temperature station 4 DO NOT PRESS ANY BUTTONS FOR 15 MINUTES ...
Page 5: ...ease retry the set up as stated above After both indoor and outdoor temperatures are displayed for 15 minutes you can place your remote temperature sensor outdoors and set your time The remote temperature sensor should be placed in a dry shaded area The remote temperature sensor has a range of 80 feet Any walls that the signal will have to pass through will reduce distance An outdoor wall or windo...
Page 6: ...6 of resistance Your distance plus resistance should not exceed 80 ft in a straight line NOTE Fog and mist will not harm your remote temperature sensor but direct rain must be avoided ...
Page 7: ...RY INSTALLATION A REMOTE TEMPERATURE SENSOR 1 Remove the mounting bracket 2 Remove battery cover 3 Observing the correct polarity install 2 AA batteries make sure they do not spring free or start up problems may occur Replace cover ...
Page 8: ... NOT press any buttons This may interfere with the signals causing temperatures to register incorrectly 1 Remove the battery cover on the backside 2 Observing the correct polarity install 2 AAA batteries 3 Replace battery cover 4 Wait 15 minutes before pressing any buttons ...
Page 9: ...n the temperature LCD s and the recorded minimum temperatures are displayed 2 Press and release the MIN MAX button to toggle to the maximum temperatures B RESETTING THE MINIMUM AND MAXIMUM TEMPERATURES 1 To reset both the minimum and maximum temperatures press and hold the MIN MAX button for 5 seconds ...
Page 10: ...rough the same dealer as this unit or by contacting La Crosse Technology directly A TX6 will monitor temperature only a TX3U will monitor temperature and display the temperature on its LCD and the TX3UP will monitor the temperature via a probe for use in pools spas etc Note When setting up multiple units it is important to remove the batteries from all existing units in operation then to insert ba...
Page 11: ... remote temperature sensor units 4 Place all remote temperature sensor units in a numeric sequential order 5 In sequential order install batteries follow the same battery installation procedures seen in section I of the Detailed Set Up Guide 6 Install batteries into the indoor temperature station D VIEWING AND OPERATING WITH MULTIPLE REMOTE TEMPERATURE SENSOR UNITS 1 To view the temperature of a d...
Page 12: ... the minimum and maximum indoor temperature and the minimum and maximum outdoor temperature 3 To reset the Minimum Maximum readings press and hold the MIN MAX button for five seconds III MOUNTING Note To achieve a true temperature reading avoid mounting in direct sunlight We recommend that you mount the remote temperature sensor on an outside North facing wall The sending range is 80ft obstacles s...
Page 13: ...ure sensor to the mounting bracket B THE TEMPERATURE STATION 1 The indoor temperature station comes with the table stand already mounted If you wish to use the table stand all that is required is to place the indoor temperature station in an appropriate location 2 To wall mount remove the table stand To do this pull down on the stand from the rear and rotate forward a Fix a screw not included into...
Page 14: ...La Crosse Technology via e mail or phone or visit our website www lacrossetechnology com Problem The LCD is faint Solution Replace batteries Problem No outdoor temperature is displayed Solution 1 Remove all batteries reinsert into remote temperature sensor first and then into the indoor temperature station 2 Place remote temperature sensor closer to the indoor temperature station 3 Be sure all bat...
Page 15: ...could be as much as 2 degrees different However the difference can be exaggerated further because the temperature sensors are designed for different working environments The indoor sensor is less responsive to ambient air currents because of the shielding effect of the display s case In addition the case can act as a heat sink to absorb and store heat from external sources i e handling of the case...
Page 16: ...eme temperatures vibration and shock should be avoided to prevent damage to the units Clean displays and units with a soft damp cloth Do not use solvents or scouring agents they may mark the displays and casings Do not submerge in water Do not subject the units to unnecessary heat or cold by placing them in the oven or freezer Opening the casings invalidates the warranty Do not try to repair the u...
Page 17: ... 2 F resolution Indoor Temperature Station Outdoor 21 8 F to 157 8 F with 0 2 F resolution Transmitting range Maximum 80 feet 25m open space Temperature Checking Interval Indoor Every 10 seconds Outdoor Every 1 minute Batteries Alkaline recommended Remote Temperature Sensor 2 x AA 1 5V Indoor Temperature Station 2 x AAA 1 5V ...
Page 18: ...18 Dimensions H x W x D Indoor Temperature Station 3 75 x 2 5 x 1 in 98 x 63 x 25 mm Remote Temperature Sensor 5 x 1 5 x 1 in 128 x 40 x 23 mm Battery life Approximately 1 year ...
Page 19: ...td for problem determination and service procedures Warranty service can only be performed by a La Crosse Technology Ltd authorized service center The original dated bill of sale must be presented upon request as proof of purchase to La Crosse Technology Ltd or La Crosse Technology Ltd s authorized service center La Crosse Technology Ltd will repair or replace this product at our option and at no ...
Page 20: ...he owner must pay any shipping charges incurred in getting your La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology Ltd will pay ground return shipping charges to the owner of the product to a USA address only Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 dama...
Page 21: ...e to any source of interference This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresentation by the seller or performance variations resulting from installation related circumstances LA CROSSE TECHNOLOGY LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL C...
Page 22: ...consequential or incidental damages therefore the above exclusion of limitation may not apply to you For warranty work technical support or information contact La Crosse Technology 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 Fax 608 796 1020 e mail support lacrossetechnology com warranty work sales lacrossetechnology com information on other products web www lacrossetechnology com ...
Page 23: ...ved including interference that may cause undesired operation Freq 433 92 MHz La Crosse Technology Made in China WS 9002U FCC ID OMO 01RX Receiver OMO 01TX sensor THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY ...