background image

La Crosse Technology, Ltd.            www.lacrossetechnology.com/support 

Page 9 

 

 

 

When temperature alert sounds, the corresponding alert icon (bell) will flash. 

 

The alert beeps once every minute, until the temperature is out of alert range. 

 

Press any button to stop alert. The alert symbol will still show. 

 

Turn alert OFF:  In normal mode, hold and release the ALERT button to select the alert. 

With HI or LO alert selected, press the 

 button to disarm that alert. 

 

Weather Station 

 

Power Requirements 

 

 

This weather station is powered by a 5 volt AC power adapter  

 

Alternatively, optional 3-AAA alkaline batteries may be used. 

 

12-Hour or 24-Hour time format 

 

 

Time can display in 12-hour (am, pm) or 24-hour format.  

 

Default is 12-hour time. 

 

Use the 

Program Menu 

to switch time formats. 

 

Fahrenheit/Celsius 

 

 

  Use the 

program menu 

to switch between Fahrenheit and Celsius. 

 

Backlight 

 

AC adapter: The backlight is on continuously when operating the weather station with the 

5-volt AC adapter. 

Note: When the AC adapter is NOT in use, the HI-LOW-OFF light feature is not available. 

  

 

HIGH: The backlight is defaulted to HI at setup when the AC adapter is in use. 

 

LOW: Press the HI-LOW-OFF button to dim the backlight.   

 

OFF: Press the HI-LOW-OFF button again to turn the backlight off.  

 

Press the HI-LOW-OFF button to return to full strength.  

Note: When the backlight is off, press any button to activate the backlight for 10 seconds.  

 

Battery power: When operating on battery power only, press and release the any button 

and the backlight will show for 10 seconds. 

 

Dashes, HH.H, LL.L or stuck Indoor Temperature/Humidity 

 

Explanation: These symbols are error messages indication the indoor sensor is outside of 

its readable range. For indoor readings, this is generally a power related issue.  

 

 

Check that the AC power cord is inserted into a working outlet. 

 

Batteries 

may be overpowered or underpowered. Remove batteries from the weather 

station.  

 

Press any button 20 times. Leave the weather station unpowered for 1-2 hours.  

 

Install fresh Alkaline batteries with correct polarity.  

 

If the indoor temperature is still shows dashes, HH.H or LL.L, the weather station may 

need replacement. 

 

Inaccurate Indoor Temperature Reading 

 

Explanation: When the indoor temperature is inaccurate, it is often due to the location of 

the display or overpowered/under powered batteries. You can test the accuracy at you 

home. 

 

Side-by-side test: Bring the remote sensor in the house and place it next to the weather 

station for 2 hours.  

 

Compare indoor and remote temperature. The temperature should be within 4 degrees 

to be within tolerance.  

 

Look for heat sources such as sunlight, door or window frames or reflected heat or cold 

near the weather station. 

Summary of Contents for T85647

Page 1: ...ittent Remote Temperature 4 Remote Temperature is stuck or HH H LL L 4 Remote sensor drains batteries quickly 4 Remote Humidity goes to dashes when temperature is cold 4 Remote sensor fell The sensor...

Page 2: ...ce Good name brand batteries make less noise which reduces the chance of RF radio frequency interference from the battery compartment Weather Station Factory Restart Explanation The factory restart re...

Page 3: ...quency reception fails five times the antenna symbol will show without bars The antenna will show full display with successful RF radio frequency reception Dashes show for Remote Temperature Explanati...

Page 4: ...bserve to see if the temperature remains on consistently for 1 hour If the temperature remains on while in the house then it is likely a distance resistance issue Move the remote sensor to different l...

Page 5: ...nology com Note Be sure to order the correct model and frequency to avoid receiving the incorrect item Call La Crosse Technology Store at 608 785 7939 or e mail from the store website if you are unsur...

Page 6: ...ure View Dew Point Temperature From the default time display press the HEAT DEW button twice and Dew Point will show instead of the remote ambient temperature The words Dew Point will show near remote...

Page 7: ...ide Gently pull down to lock the screw in place Option 2 Insert the mounting screw through the front of the remote sensor and into the wall Tighten the screw to snug do not over tighten Position Weath...

Page 8: ...l Temperature Alerts Explanation The remote and indoor temperature alerts are set in two separate steps Set the alert value Arm Disarm the alert Select Temperature Alert Values Hold the ALERT button f...

Page 9: ...f Press the HI LOW OFF button to return to full strength Note When the backlight is off press any button to activate the backlight for 10 seconds Battery power When operating on battery power only pre...

Page 10: ...ds press any button except the ALARM button to turn the alarm off No WWVB Tower Icon The forecast station has not received a WWVB time signal in the past 24 hours Position the forecast station for bet...

Page 11: ...lease the or buttons to select the correct date Confirm with the TIME SET button and move to F C 10 Note The Day of the Week will set automatically when the year month and date are set 11 FAHRENHEIT C...

Page 12: ...with AC adapter only to determine if batteries were an issue Weather station has missing segments Explanation When parts of numbers letters or pictures are missing on the display it is often power re...

Reviews: