background image

La Crosse Technology, Ltd.  

Page 6 

 

 

Check that the cups spin freely. 

 

WIND SPEED IS INACCURATE 

 

 

Check the unit of measure (MPH, KM/H or M/S). 

 

Check to see if the Wind speed station receives the same repetitive wind speed recording 
from the sensor multiple times. 

 

Confirm the direction is working correctly. 

 

Check that the cups turn freely.  

 

Check for obstructions that prevent clear wind flow to the cups.  

 

Check mounting. In most cases, the wind sensor needs to be 6 feet or more above the highest 
point on the roof in order to clear nearby obstructions and read accurately. A 50-foot 
clearance in all directions is best.  

 

It is helpful to send pictures of the sensor mounting, if you need to contact customer support. 

 

Check that your batteries are fresh in the thermo-hygro sensor and the Wind speed station. 

 

UNDERSTANDING WIND READINGS 

 

Current Wind Speed:

 

The current wind speed, which represents the highest speed in the past 30 seconds. This should 
correspond to the wind graph. 
  

Top Wind Speed: 

Highest recorded wind speed in time interval. Default is 1 hour, controlled by the 

Wind History feature, details below. 

 
Wind Speed History:

 

Press and release the WIND button to view the maximum wind history values. 
• One Hour: past 60 minute period (default Top Speed record, already shown) 
• 24-hour: Past 24-hour period, from last record 
• 7 Days: Past 7-day period, from last record 
• Month: Defined by Calendar Month i.e. January 1 - January 31 
• Year: Defined by Calendar Year i.e. January 1 - December 31 

Note: 

After 5 seconds, all readings default back to the 1-hour top wind speed.

 

 
Wind Speed Graph: 

 

The wind speed graph with sections based on current wind speed.  

 

One segment will flash indicating current wind speed. 

 

Feels Like Temperature: 

Wind Speed | Temperature | Humidity combined: 
• When outdoor temp is higher than 80˚F, displays heat index 
• When outdoor temp is lower than 50˚F, displays wind chill 
• When outside of the above ranges will display current outdoor temperature.  
 
 
 

RESET WIND SPEED HISTORY 

 
• Press the WIND button to view individual wind speed readings. 
• Hold the MINUS button for five seconds to reset 

each individual 

value. 

• Wind speed reading will reset to current wind speed. 

Summary of Contents for CA84688

Page 1: ...humidity Wind Speed 3 Inaccurate outdoor temperature humidity 3 Outdoor Readings are stuck or OFL 4 Intermittent Sensor Readings 4 sensor drains batteries quickly 4 Fahrenheit Celsius 4 HI LO Temperature Humidity Records 5 Reset HI LO Temperature Humidity Records 5 Wind Cups spinning slow or not spinning 5 Replace wind cups 5 Wind speed is 0 00 5 Wind speed is inaccurate 6 Understanding wind readi...

Page 2: ...r performance WEATHER STATION FACTORY RESTART The factory reset will return the wind speed station to its default settings This will clear all previous recorded history so you may want to write down data before taking this step 1 Hold down both the WARNING and ALERTS button together for 5 second This will clear all recorded weather data and reset the station s settings back to default 2 The weathe...

Page 3: ... 10 feet apart for 15 minutes to establish a solid connection 9 After 15 minutes place the remote sensors in appropriate shaded locations 10 Press and release the CH button to view channels 1 2 or 3 on the wind station when multiple sensors are used Additional sensors are sold separately are available for purchase here www lacrossetechnology com tx141th bch temperature humidity sensor WIND THERMOH...

Page 4: ... radio frequency communication is not always 100 on Certain temporary conditions can cause it to go out for a time e g 100 humidity If a miss happens Hold the WIND button for 5 seconds to search for sensor The units try for 20 minutes to reconnect After 20 minutes the sensor stops trying for an hour to preserve battery life After the 1 hour break the sensor will start another 20 minute re connect ...

Page 5: ...Individual readings will reset to current temperature humidity etc WIND CUPS SPINNING SLOW OR NOT SPINNING Check for debris or ice in cups Check mounting location Look for obstructions that prevent the wind from reaching the sensor In most cases the wind sensor needs to be 4 6ft above the highest point on the roof in order to clear nearby obstructions and read accurately A 50 foot clearance in all...

Page 6: ...d Speed Highest recorded wind speed in time interval Default is 1 hour controlled by the Wind History feature details below Wind Speed History Press and release the WIND button to view the maximum wind history values One Hour past 60 minute period default Top Speed record already shown 24 hour Past 24 hour period from last record 7 Days Past 7 day period from last record Month Defined by Calendar ...

Page 7: ... alert Alerts setting order High Wind Speed ON OFF CURRENT wind High Wind Speed Value 0 99mph 0 159kph Outdoor LOW Temperature ON OFF Outdoor LOW Temperature Value 40 F to 140 F 40 C to 60 C Outdoor HIGH Temperature ON OFF Outdoor HIGH Temperature Value 40 F to 140 F 40 C to 60 C Outdoor LOW Humidity ON OFF Outdoor LOW Humidity Value 10 RH to 99 RH Outdoor HIGH Humidity ON OFF Outdoor HIGH Humidit...

Page 8: ...ree user will select channel first 1 2 3 then select outdoor alert FROST Alerts cannot be set for channel 2 3 if no additional sensors are connected Frost Warning When the outdoor temperature is between 28 F to 37 F 2 C to 3 C and the frost warning is active a Frost Warning will alert you with a flashing snowflake icon and the station will sound Outside of this range the frost warning is not activ...

Page 9: ... feet 100 meters in open air not including walls or floors Mount the sensor vertically to allow moisture to drain out properly http bit ly TH_SensorMounting DISTANCE RESISTANCE INTERFERENCE Distance The maximum transmitting range in open air is over 330 feet 100 meters between the sensors and the Wind speed station Consider what is in the signal path between the Wind speed station and the sensors ...

Page 10: ...old the SET button five seconds so that BEEP and the word ON will flash Press and release the or button to turn this to OFF to avoid beep sounds when pressing a button Confirm with the SET button and move to the hour 2 The hour will flash Press and release the or button to select the correct hour Confirm with the SET button and move to the minutes 3 The minutes will flash Press and release the or ...

Page 11: ...ture is below 32 F 0 C and the forecast is rainy or stormy The Wind speed station calibrates barometric pressure based on its location over a period to generate an accurate personal forecast Please allow 7 10 days for barometer calibration The forecast station samples the barometric pressure every twelve minutes These samples are averaged hourly and daily then stored in nonvolatile memory IMPORTAN...