background image

La Crosse Technology, Ltd.  

Page 3 

 

 

 

TX1414Wv2 Wind Speed and Thermo-hygro 

 

TX141TH-BCH can be added on channel 2 or channel 3 for additional 

temperature/humidity readings. 

 

The above 433MHz sensors will read to this professional weather station.  

 

ADD-ON SENSORS 

 

You can add up to two TX141TH-BCH sensors for extra temp/humidity 

readings on channels 2 or 3. (Wind Sensor uses channel 1). 

1.

 

Remove the battery cover from all the sensors (leave battery covers off until all 

sensors are received by the wind station). 

2.

 

Set the first additional sensor to Channel 2 and insert 2 AA batteries.  

3.

 

Set the second additional sensor to Channel 3 and insert 2 AA batteries. 

4.

 

Hold the DOWN arrow button on the wind station for 5 seconds to search for 

sensors. 

5.

 

Press the TX button on each sensor. 

6.

 

When connection is established, the temperature & humidity for each of the 

selected channels will appear.  

7.

 

Install the battery covers on each sensor. 

8.

 

Keep sensors and the wind station 5-10 feet apart for 15 minutes to establish a 

solid connection.  

9.

 

After 15 minutes, place the remote sensors in appropriate shaded locations. 

10.Press and release the DOWN arrow button to view channels 1, 2 or 3 on the 

wind station when multiple sensors are used.  

  

WIND | THERMO-HYGRO SENSOR 

DASHES SHOWN FOR OUTDOOR TEMPERATURE/HUMIDITY/WINDSPEED 

 

 

Dashes means the unit have lost connection between the display and the 

outdoor sensor.  

 

Batteries are the most common problem.   

 

Distance/Resistance can cause loss of sensor signal. Avoid having more than 1 

wall, window, tree etc., between the display and the sensor. UV coated windows 

may actually reflect the signal. Stucco walls will absorb the signal. 

 

It may be helpful to orient the weather 90 degrees towards the sensor for better 

reception.  

 

Sensors operate best when elevated at least 6 feet. 

 

Remove the batteries from the sensor for 2 minutes. Replace the batteries in the 

Thermohygro sensor and after 5 minutes press and hold the DOWN 

ARROW button for 5 seconds. Wait 10 minutes. If the unit does not receive a 

reading from all the sensors please try the factory reset. 

 

INACCURATE OUTDOOR TEMPERATURE/HUMIDITY  

 

 

The thermo-hygro sensor reads the environment. When the sensor reads high 

during the day but not at night it is a mounting problem. 

 

Side-by-side test: Bring the thermo-hygro sensor in the house and place it 

next to the Professional weather station for 2 hours.  

Summary of Contents for 327-1414Wv2

Page 1: ...ty Windspeed 3 Inaccurate outdoor temperature humidity 3 Outdoor Readings are stuck or OFL 4 Intermittent Sensor Readings 4 sensor drains batteries quickly 4 Humidity shows OFL but temperature works 4...

Page 2: ...the battery compartment A minimum voltage of 1 48V for each battery is necessary for proper performance WEATHER STATION FACTORY RESTART The factory reset will return the Professional weather station...

Page 3: ...haded locations 10 Press and release the DOWN arrow button to view channels 1 2 or 3 on the wind station when multiple sensors are used WIND THERMO HYGRO SENSOR DASHES SHOWN FOR OUTDOOR TEMPERATURE HU...

Page 4: ...go out for a time e g 100 humidity If a miss happens Hold the DOWN ARROW button for 5 seconds to search for sensor The units try for 20 minutes to reconnect After 20 minutes the sensor stops trying fo...

Page 5: ...Press the HEAT DEW button repeatedly to toggle between o Feels Like temperature o Heat Index outdoor o Dew Point outdoor Note Feels Like Temperature is the perceived outdoor temperature Temperatures b...

Page 6: ...ove the highest point on the roof in order to clear nearby obstructions and read accurately A 50 foot clearance in all directions is best It is helpful to send pictures of the sensor mounting if you n...

Page 7: ...ue will blink in set mode 3 Press the ARROW buttons to adjust the values 4 Press the ALERTS button to confirm and move to the next alert The alert setting order High Wind Speed channel 1 only Outdoor...

Page 8: ...al weather station is from other electronics in the home Resistance Obstacles such as walls windows stucco concrete and large metal objects can reduce the range When considering the distance between t...

Page 9: ...lash Press and release the buttons to turn this to OFF to avoid beep sounds when pressing a button Confirm with the TIME SET button and move to atomic time WWVB ON OFF 2 WWVB and the word ON will flas...

Page 10: ...the Atomic Time Signal WWVB from Fort Collins Colorado The station will search for WWVB signal up to 5 minutes then return to receiving the outdoor sensor The first search is 2 hours after startup Th...

Page 11: ...correctly to the Professional weather station and the outlet 2 Remove the batteries 3 Press the LIGHT button If the backlight comes on and the display is active your AC cord works 4 Wait 15 seconds to...

Page 12: ...reased accuracy The longer the Professional weather station operates in one location the more accurate the forecast icons will be Install fresh alkaline batteries with correct polarity WEATHER STATION...

Reviews: