English
50 EN
English
-
+
2.6 “Copy group” function
This feature allows you to copy the selected coffee group settings for all other machine units.
Operate as follows:
1) position the cursor over
“C
opy group”
using the
and keys and press the key;
2) set the group to be copied to the other machine groups by
using the and keys and
confirm by pressing
“
OK
” key.
3) at the end of the process, all the units will have the
same parameters.
PLEASE WAIT
TECHNICAL PROG.
KEY MENU
SELF LEARNING
Copy unit
3
CONFIGURATION
DATA MENU
Boiler-
The heating element and the self-leveller feature
of the boiler are activated or deactivated with the “Boiler”
ON/OFF function.
Boiler Pressure
- indicates the pressure of the boiler;
0.6–1.6 bar (9–23 psi).
BOILER -
this parameter includes the entries for setting the
temperature of the boilers, values that can be set are 60 to
110°C (140 to 230°F) in steps of 0.5°C. In this menu there
is the possibility of programming a temperature offset for
the boilers, adjustable in a range of +/- 2°C. The standard
setting is the current value of +1.5°C.
Level Sensitivity
- indicates the degree of sensitivity of
the level probe, which then operates the filling of the boiler
with water. For safety reasons, automatic
level control of
the self-leveller service-boiler is disabled when the service-
boiler heating element is turned off.
- Note: set a value of 1 if the machine is installed with very
conductive water.
Set a value of 3 if the water used is not very conductive
(very soft).
UNIT OF MEASUREMENT
- Includes 2 sub-menus:
temperature
- can be set to: °C, centigrade - Celsius or
°F, Fahrenheit.
pressure
- can be set to bar or psi.
-
+
CONFIGURATION
Boiler
ON
Boiler pr.
1.3 bar
BOILER
Level sensitivity
2
UNIT OF MEASUREMENT
2.7 Configuration Menu
Time control
-
shows dispensing time on display: YES/
NO (from 1 sec to 1 hour).
Buzzer
- enables/disables all acoustic signals when keys
are pressed or messages are displayed: YES/NO.
Flush
- Adjusts the duration of the FLUSH function,
adjustable between 0 and 3 seconds.
Low power
- YES/NO
WASHING OPTIONS -
- Allows the user to select the run
time and block time for the “Wash” and “Water change”
functions.
Customer programming
- Customer programming: YES/
NO.
By activating the function (YES), it is possible to provide
the user with additional functions:
- change the cup warmer level (but not the level settings)
- turn the coffee boiler on/off.
- activate energy saving mode.
Programming lock
- Lock programming lock: YES/
NO. By activating the function (YES), all the keys on the
programming keypad are locked, including the cup-warmer
key. The only actions permitted are the key sequence for
technical access, pressing the arrow key
OK
1
2
to perform
softener regeneration and message removal.
Drying -
Varies drying time from 0 to 5 with intervals of 0.1
seconds “if Drying kit is present”.
Summary of Contents for M200
Page 2: ...M200 13 4 6 11 8 9 9A 20 15 23 12 15 1 TSb 2 3 9 4 I...
Page 81: ...English 76 EN English 4 2 Cup warmer 1 2 3...
Page 82: ...English 77 EN English 4 3 Stainless steel front panel 2 1...
Page 85: ...English 80 EN English 1 2 SIDE PANEL WITH LED...
Page 88: ...English 83 EN English 4 8 Coffee boiler...
Page 89: ...English 84 EN English 4 9 Electrical unit 1 2...
Page 90: ...English 85 EN English 4 11 Volumetric pump 4 10 Safety thermostat...
Page 91: ...English 86 EN English 4 12 Battery CR 2032 3V BATTERIA...