Summary of Contents for M100 Dosatron

Page 1: ...M100 GT HD Dosatron Turbo Milk MANUALE DEL TECNICO ENGINEER S MANUAL MANUEL DU TECHNICIEN TECHNIKERHANDBUCH MANUAL DEL TÉCNICO MANUAL DO TÉCNICO rev MT M100TurboMilk P0 1907 ...

Page 2: ...I M100 1 6 11 8 9a 9 20 13 19 19 19 15 23 Turbomilk 9c Tsn 12 35 Tsb Cold Touch DX 9b Cold Touch SX 9b ...

Page 3: ...une configurazioni di prodotti LEGENDE 1 Hauptschalter 6 Manometer Pumpe 8 Heißwasserausgabe 9 Dampfausgaberohr 9a Dampfausgaberohr Turbosteam 9b Dampfausgaberohr Turbosteam Cold Touch 9c Milchausgaberohr Turbo Milk 11 Filterhalter 12 Heißwasser Drucktaste 13 Wahlschalter Turbosteam Turbomilk 15 Auffangschale 19 Boiler Kaffee 20 Drehknopf Dampfabgabe 23 Tassenerwärmer 35 Taste STOP KONTINUIERLICHE...

Page 4: ...0 22 x 2 10 0 22 x 2 10 Boiler caffè Coffee boiler Chauffe eau café Boiler Kaffee Calentador café Boiler do cafè acqua water eau Wasser agua água 0 40 x 2 160 12 GT 15 HD 0 40 x 3 0 40 x 4 Caldaia Service boiler Chaudière Heizkessel Caldera Caldeira 133 tipo di macchina Type of machine type de machine Maschinentypen modelo de la máquina tipo de la màquina acqua vapore water steam eau vapeur wasser...

Page 5: ...10 2 ø100 3 9 M100 GT M100 HD M100 DT L L1 mm inches Weight Kg pounds DIMENSIONS 2 gr 3 gr mm inches 817 32 2 1017 40 568 22 4 89 196 768 30 2 105 232 4 gr 1217 47 9 968 38 1 120 265 L L1 mm inches Weight Kg pounds DIMENSIONS 2 gr 3 gr mm inches 817 32 2 1017 40 568 22 4 87 187 768 30 2 100 221 4 gr 1217 47 9 968 38 1 123 271 ...

Page 6: ... 27 Operations for Machine Grinder Dispenser Bluetooth communication 28 BDS activation and sensor configuration 30 Configuration Magnum Bluetooth grinder dispenser sensors 31 Setting recipes and connections with Grinder Dispenser 32 Operating logic 33 Grinder control parameters configuration 34 Dose time variation relative to the Magnum Bluetooth Grinder Dispenser 37 Wi Fi configuration 38 Enablin...

Page 7: ...ial warming stage or that the boiler pressure has decreased to below 0 5 bar It shows the boiler s warming status and appears if one or more boilers are still in their initial warming stage or if their temperature decreases to below 55 C Pressing the STOP continue coffee icon will cause dispensing to occur at the current tem perature All the other icons are disabled until required operating pressu...

Page 8: ...payment system the red icon indicates that the cash system has denied the transaction the blue icon indicates that the cash system has approved the transaction CONTROL OF THE FLOW ONLY IF IN USE When this icon lights up it means that it is necessary to adjust the grinder dispenser to tighten or loosen the grinding in order to return the coffee dose to the correct parameters The icons that are show...

Page 9: ...flow chart Technician programming Milk versions with Turbo Milk Demand Effectu Demand Effectu Demand Effectu 0000000 050 00 P0 4 6 047 00 P0 3 6 061 00 M0 V00 49 18 19 Testing versions with Turbosteam L and Turbosteam R ...

Page 10: ... menu by pressing 1 the key 2 the key 3 typing the password and pressing Return to the previous menu or exit the programming menu by pressing the key 1 Programming access TECHNICIAN PROGRAMMING versions with Turbosteam L and Turbosteam R ...

Page 11: ...EAR Press the icon AUTOMATIC SWITCH OFF SWITCH ON The machine can be set to switch off and switch on at programmed times During the machine off phase the display light is dimmed Note Whenthemachineisworkingin the automatic on off function do not use the general switch 1 to switch off the machine If this happens the machine will not be able to switch on again automatically FORCED SWITCH ON Push any...

Page 12: ...bosteam selector on position TS 1 Steam Air number of times that steam and air were dispensed using the Turbosteam selector positions TS 2 4 Hot milk number of times hot milk was dispensed Cold milk number of times cold milk was dispensed Total Coffee total number of coffee based beverages time since last start up Scroll through the entries using the and arrows In the Selection Counters menu the p...

Page 13: ...he icon to display the Water Change submenus 1 The items are scrolled by pressing the icons 1 The items are scrolled by pressing the icons 1 The items are scrolled by pressing the icons Demand Effectu Demand Effectu Demand Effectu 2 Press the key to clear reset 2 Press the key to clear reset 2 Press the key to clear reset Example of a Turbosteam key selection counter Counters versions with Turbost...

Page 14: ... 3 4 Version DT HD GT Turbosteam TS TS 2 NO TurboMilk YES NO 1 key 5 keys 7 keys NOTE machines configured with 1 dispensing key do not allow BDS and connection to the payment system Press the icon to display the Version submenus The submenus under Version show the memory versions Master 047 00 P0 Slave 050 00 P0 Display 061 00 M0 Firmware V00 49 18 19 Bluetooth WIFI VEBOX TurboMilk Turbosteam Scro...

Page 15: ...ears on the services display The parameters displayed are Dv Volumetric meter incremental counter tG dispensing time TB instant coffee boiler temperature RB activation coffee boiler resistance P service boiler pressure Liv service boiler water level level signal Rc service boiler resistance Evc service boiler load solenoid valve TV Turbosteam wand steam temperature 5 Programming measures function ...

Page 16: ...ter added will be displayed which can be corrected manually using the buttons Afterwards confirm the values by pressing the icon Press the icon to exit the SELF LEARNING phase Place a container suitable for the amount you wish to fill beneath the hot water outlet and press the icon The buzzer sound will stop and the red border at the top left of the icon will disappear The buzzer sound and the red...

Page 17: ...d e g key 1 the icon of the key in question remains selected on the display When the desired level is reached in the cup or cups press the key again Continue to program all the coffee keys By pushing the coffee buttons on the services display the doses entered can be viewed with the values of the impulses of the volumetric dosing devices The doses entered with the self learning function can be cor...

Page 18: ... all the groups will have the same parameters Clone function Press the icon to confirm Press the icon This feature allows you to replicate the coffee unit settings for all other machine groups Press one of the coffee keys e g Group 3 1 2 3 4 ...

Page 19: ...English 14 EN This function lets you set the profile for the pressure at which the coffee is dispensed Pressure profile only on HD machines Pressure profile Start Stop key 1 3 4 B 2 A 2 3 1 ...

Page 20: ...spensing phases Exit menu Confirm data For example phase 2 in yellow will have a duration of 7 seconds at 9 bars phase 3 in blue will have a duration of 5 seconds at 7 bars Phase 1 Is tied to infusion as shown in the image above it cannot be modified and has settings time and pressure similar to those of a traditional machine To modify phase 1 you must access the Programming menu and set the Infus...

Page 21: ...onds using the keys Select another phase to modify The change to the pressure profile tied to the key 3 strong coffee of group 3 is evident when comparing the initial profile with the modified one Confirm changes to the profile by pressing the key Press the key to exit leaving the profile in the initial condition Change the pressure using the keys Change the seconds using the keys Initial profile ...

Page 22: ...essor motor Eds EDS solenoid valve Em Erp Milk solenoid valve Pressure reset solenoid valve Gp1 Gp4 Proportional solenoid valve boiler activation percentage Boiler activation percentage Modulation percentage of the heating power of the boiler Boiler resistance Activation of resistance elements on the basis of the power selected Total power divided into RC1 RC2 Full power cycle RC1 ON RC2 ON Low po...

Page 23: ...er level in boiler Components to operate are selected by pressing icons the operation takes place by pushing the button which indicates the name of the part Testing Testing Testing Here is the table of symbols used to define the moving parts that can be accessed MP Pump motor G1 G4 Coffee dispensing solenoid valves Eac Hot water solenoid valve Eaf Cold water solenoid valve Eav Steam water solenoid...

Page 24: ...nce elements on the basis of the power selected Total power divided into RC1 RC2 Full power cycle RC1 ON RC2 ON Low power cycle RC1 ON RC2 OFF RC1 OFF RC2 OFF RC1 OFF RC2 OFF MP pump motor G1 G3 Dispense coffee solenoid valve Eac Hot water solenoid valve Eaf Cold water solenoid valve Ev Steam solenoid valve Evc Charge boiler solenoid valve Em Milk solenoid valve Ed Diverter solenoid valve Elf1 Wat...

Page 25: ... display Press the key and follow the instructions on the display Milk Wash press the key NOTE More information on the wash cycle can be found in the Cleaning and Maintenance chapter Time press the key This menu makes it possible to set the times requests appear for the water change in the boiler the coffee circuit wash and the milk circuit wash Select which of the following times to set Change Co...

Page 26: ... water and steam With request scheduled the user can only change the time the request appears Coffee press the key Select which type of coffee wash you want to perform For example Change the time depending on your requirements and confirm with the key The time appears under the key NOTES It is possible to cancel the scheduled wash request by pressing the key in this case no time appears under the ...

Page 27: ...g the key By pressing the key the following screen appears on the services display Press the icon Press one of the Turbosteam keys Set the values using the keys Confirm the data inserted using the key or exit and leave the previous data using the key By pressing the key the following screen appears on the services display Press the parameter to be modified versions with Turbosteam L and Turbosteam...

Page 28: ...using the keys Confirm the data inserted using the key or exit and leave the previous data using the key Milk versions with Turbo Milk Press the icon Press one of the Turbo Milk keys Press the parameter to be modified Set the values using the keys Confirm the data inserted using the key or exit and leave the previous data using the key 1 2 3 5 4 2 3 1 ...

Page 29: ...e key displays the barred icon of the resistance all resistances are disabled 10 Heating element Press the icon Service personnel can switch on or switch off the electric heating service boiler and groups boilers in this way Icon in programming enabled resistances icon main menu Icon in programming disabled resistances icon main menu 1 2 3 1 2 ...

Page 30: ...t of the Acaia scales for weighing the amount of coffee dispensed YES NO Payment Systems allows a payment system to be configured when connected Level Sensib indicates the degree of sensitivity of the level probe which thenoperatesthefillingoftheboilerwith water For safety reasons automatic level control of the boiler is disabled when the boiler resistance is turned off Note set a value of 1 if th...

Page 31: ...descending from 100 to 0 Maintenance includes 4 submenus for setting maintenance parameters Max cycles the number of cycles set Max days the number of days set No cycles days this is the number of cycles and days until next maintenance Maintenance YES NO Enables YES or does not enable countdown of the cycles and days until the next maintenance activity Bds see section BDS Activation in the followi...

Page 32: ... half a degree centigrade of offset Confirm the data inserted using the icon or exit and leave the previous data using the icon Bluetooth Menu The parameters that can be set are MM1 MM2 1 to 2 grinders can be connected Search the machine will find all bluetooth devices within 10 m Reset cancels the connection with the associated device Note during connection with bluetooth grinders dispensers the ...

Page 33: ...e machine can be linked to a Bluetooth device Type the password and then press The machine will find all Bluetooth devices within a range of 10 metres 1 The items are scrolled by pressing the icons 2 Press the icon to confirm the selected device an asterisk will appear next to the line of the grinder dispenser to indicate the successful Bluetooth association with the machine Procedure for Bluetoot...

Page 34: ...n the event of communication problems the COMMUNICATION FAILURE message will appear on the display followed by the name of the disconnected grinder dispenser The message disappears automatically when the Bluetooth connection is restored A common cause of this failure is the grinder dispenser being turned off with the machine turned on 9 10 ...

Page 35: ...n entered TECHNICAL MENU CONFIGURATION BLUETOOTH Press the icon to confirm Press the icon 1 The items are scrolled by pressing the icons 2 Press the icon ENABLED SPECIAL DOSE White Blue SINGLE DOSE Red DOUBLE DOSE Green BDS activation and sensor configuration Note With BDS active the payment systems cannot be activated Cannot be activated on HD machines 3 1 2 B D S 1 2 ...

Page 36: ...ft sensor Red Double dose Right sensor Green Double dose Left sensor Green Single dose Right sensor Red Single dose Left sensor Red Right sensor disabled Single Dose Right sensor Red Left sensor disabled Left sensor disabled Double dose Right sensor Green Double dose Left sensor Green Right sensor disabled SPECIAL DOSE Blue B D S 1 2 B D S 2 1 B D S 0 2 B D S 0 1 B D S 1 0 B D S 2 0 B D S 1 2 ...

Page 37: ...reen SINGLE DOSE Red SPECIAL DOSE White Blue Setting recipes and connections with grinder dispenser The filter holder key and machine association logic is the following 1 A or 2 A activation of the first actuator filter holder with single delivery spout 1 B o 2 B activation of the second actuator filter holder with double delivery spout 1 C or 2 C activation of the third actuator with filter holde...

Page 38: ...unable to grind a second dose of coffee The grinder dispenser will automatically release when the enabled key is pressed or when the two minutes of waiting time have elapsed B L O C K E D BDS system enabled Dispensing disabled keys off NOTE Start Stop key is always active Dose grinding and dispensing activated key on Operating logic ...

Page 39: ... previous data using the key Grinder control parameters configuration Grinder Control 1 Grinder Control 2 only if the machine is connected to a wireless grinder dispenser The parameters that can be set are not in use manual grinder control for grinder dispensers with no bluetooth connection option automatic grinder control bluetooth connection with grinder dispenser Note For proper operation of th...

Page 40: ...ef of double coffees first for proper func tioning of grinder control control of the flow only if in use The appearance of this animated icon means that adjustments need to be made to the grinder dispenser to tighten or loosen the grinding to return coffee dispensing to the default parameters The icons that are shown are means that the grinding needs to be loosened flow of coffee is lower than the...

Page 41: ...more until the message Qref OK appears on the services display with audible sound 8 Dispense single coffees 5 or more until the message Qref OK appears on the services display with audible signal 9 Dispense any special blend coffees 5 or more until the message Qref OK appears on the services display with audible sound 10 Enter programming and check that the Qref values set are present Repeat the e...

Page 42: ...re DOSE 2 for the double measure DOSE 3 for the continuous measure Note single measure s and continuous measure grinding time variation in user mode is 25 hundredths of second 0 1 4 second Double measure s grinding time variation in user mode is 50 hundredths of second 0 1 2 second Grinding in continuous mode if equal to zero DOSE 3 0 can only be modified by the technician Dose time variation rela...

Page 43: ...re the parameters to the standard parameters MAC Represents the Mac address of the WiFi module present in the machine It is a parameter that is only displayed cannot be changed fTX reduces data transmission to the remote server transmits all data daily at machine startup faults washings per event level 1 plus hourly counts level 2 plus pings every 10 min default Place the cursor on the item CONNEC...

Page 44: ...figurations 1 key 5 keys 7 keys NOTE when the machine is configured with 7 dispensing keys the FLUSH key cannot also be present 5 keys 7 keys 1 key Press the icon and Set a time from 0 to 5 seconds By entering the programming menu you can activate the FLUSH key Press the icon to confirm Enabling Flush key 2 1 3 ...

Page 45: ...of each coffee dispenser group The FLUSH key makes it possible to briefly operate the group rinse between 1 and 5 seconds before inserting the filter holder If you want to interrupt this cycle it is possible to stop the dispensing at any time by pressing any key on the unit The FLUSH key is not tracked in the cycle counters and remains free and active with payment systems in operation Start Stop E...

Page 46: ...lay a logo for the group display and one for the services display Copy the file custlogo bmp if the user wants to display the same logo on all displays NOTE If in the USB pen drive there are all files logo will be displayed the image of the file custlogo bmp Insert the USB pen drive in the dedicated slot on the machine the icon will appear on the services display Once loading is complete remove th...

Page 47: ...English 42 EN Return to the programming menu and press the icon Press the icon to confirm Services logo Press the icon Press the icon Services display logo 1 2 5 3 4 ...

Page 48: ...e coffee groups the logo appears after 1 minute of inactivity Press the icon to confirm If you do not want to load cus tom images M100 also offers a default logo that is always present in the machine It is the La Cimbali logo The La Cimbali logo will be displayed on the services display and if the item group is activated it will also be displayed on the coffee group display In the programming menu...

Page 49: ...ed With the subsequent restart the upgrade of the two microprocessors master and slave begins with the file The correct recognition of each file by the machine is signalled by a buzzer 200ms ON Pen Drive operating LED status flashing running At the end of the slave CPU update programming of the master CPU begins For the entire duration of this phase the buzzer sounds intermittently 200ms ON Pen Dr...

Page 50: ...on procedure can be performed at any time by starting the machine with Dip 3 ON The following message appears on all the displays when turned on Using a pen hold down the centre of the cross repeat the operation in all the points where the cross appears Perform the calibration on all the displays or only on those where it is required At the end of the operation turn off the machine and return the ...

Page 51: ...starts and the following message appears Remove the USB Pen Drive Enter the standard data update the machine data and reactivate the heating element if necessary START UP WITH RECOVERY FILES Switch off the machine and insert the USB Pen Drive Turn the machine on again when it restarts recovery will begin The start of the procedure is indicated through an intermittent beep During the update the mac...

Page 52: ... test procedure can be performed at any time by starting the machine with Dip 5 ON Ensure that the information on the display is green with no pressure on the screen if the information is red check for any undesired pressure on the edge of the screen At the end of the operation turn off the machine and return the Dip 5 to OFF ...

Page 53: ... is malfunctioning Check the status of the USB port and its connections in order to identify possible causes of excessive consumption e g short circuit Once the cause of the malfunction is fixed the USB port should restore itself automatically and return to normal operation If the problem persists replace the CPU board Check cabling Replace the sensor Replace the card Replace the fuse Clean the co...

Page 54: ...tion wrong grind too fine excessive dose ground coffee type changed qref calibration wrong grinding too coarse grinder dispenser blocked insufficient dose of ground coffee Check if the safety thermostat of the group x boiler has been triggered and reset it if necessary Check if there are interruptions or detached fastons on the cabling Check that the group x boiler resistance is not interrupted an...

Page 55: ...ater softner filter The machine has displayed the message to warn the user that maintenance must be performed Carry out maintenance operations Incorrect keyboard configuration if applicable Wiring interrupted Card failure Incorrect keyboard configuration if applicable Wiring interrupted Card failure Incorrect association with measure grinder Measure grinder turned off Incorrect association with me...

Page 56: ...dule communication malfunction Event only archived and not displayed on the display during normal machine operation Replace SD card Check the insulation Check the wiring and connections Check wiring Replace Turbosteam board Action desired by the user by entering the special code applicable only for machines with TFT display Initialisation malfunction history and washing history for machines withou...

Page 57: ...D SETTING TUTTE LE OPERAZIONI DEVONO ESSERE EFFETTUATE A MACCHINA SPENTA 13 Removal of the side panels ALL OPERATIONS MUST BE PERFORMED WITH THE MACHINE OFF AND COLD TO ALWAYS USE THE NECESSARY SAFETY EQUIPMENT SHOES GLOVES 2 1 3 ...

Page 58: ...English 53 EN 14 Cup Warmer 1 2 3 ...

Page 59: ...English 54 EN 15 Stainless steel front panel 1 2 ...

Page 60: ...English 55 EN The back panel may be removed only after the cup warmer has been removed 16 Rear panel 1 2 ...

Page 61: ...English 56 EN Slip a tube on the drain fitting and turn the nut in the direction indicated in the future 17 Draining the boiler water ...

Page 62: ...English 57 EN Remove the resistance only after emptying the boiler 18 Removing the boiler heating element 4 1 2 3 ...

Page 63: ...English 58 EN 19 Coffee boiler 1 4 7 9 2 3 5 6 8 10 11 ...

Page 64: ...English 59 EN ...

Page 65: ...English 60 EN 20 Services display panel G2 SV SV G1 G2 G1 G4 G3 G3 G4 SV 947 101 000 4 3 2 1 V G G G G S 1 2 3 4 5 ...

Page 66: ...English 61 EN 21 Turbosteam control and lance 22 Junction Box 23 Safety thermostat 1 2 1 2 3 5 4 ...

Page 67: ...SWITCHED OFF Under standard conditions the dip switches are positioned on OFF The dip switches have the following functions DIP 1 OFF DIP 2 OFF DIP 3 OFF ON calibration of the touch displays DIP 4 OFF DIP 5 OFF ON touchscreen test DIP 6 OFF DIP 7 ON DIP 8 OFF 24 Peristaltic pump 25 CPU dip switch 1 2 3 ...

Page 68: ...English 63 EN FUSE BATTERY Battery Fuse CR 2032 3V CR 2032 3V ...

Page 69: ...English 64 EN 26 TURBOSTEAM on the left side ...

Page 70: ...cran tactile de la machine comporte les icônes du Turbosteam côté gauche et du Turbosteam côté droit DE Ist der TURBOSTEAM in Betrieb leuchtet die rote LED der TS Platine und blinkt regulär Auf dem Touchscreen Display der Maschine befinden sich die Symbole Turbosteam LINKS und Turbosteam RECHTS ES Cuando el sistema TURBOSTEAM está en funcionamiento el LED rojo presente en la tarjeta TS está encend...

Page 71: ...LI UL TA1 TA2 NA1 NA2 TB1 NB1 CAMBIA TENSIONE N1A S1 S3 T2 T4 R1 R2 N1A N1B N1B N2B NC1 NC2 NC3 N1A N1B N2B N1 N2 N3 N1A N1B N2B R1 S1 T1 J3 J2 R3 T3 S2 TB1 TB2 NB1 NB2 MP NB3 NB2 NB3 TB2 TB1A CS1 MP1 MOTORE POMPA SCALDATAZZE NB2 TA1 NA1 NA2 NA2 NA2 TA2 TA2 TB2 TB1A TA2 TB3 TB4 TA2A TA2A TA2A NF FF FILTRO MONOFASE DELTA 16MXXX ALIMENTATORE SW S100 24 F_AL N_AL J3 ALIMENTAZIONE SCHEDA DISPLAY ELETT...

Page 72: ... DA CPU BASSA TENSIONE SCHEMA DI POTENZA M100 BOILER NC1 NC2 NC3 N1A N1B N2B J3 J2 N1 J4 J5 FB1 FB2 FB43 TERMOSTATO BOILER TERMOSTATO BOILER TERMOSTATO BOILER TERMOSTATO BOILER RB1 DX RB2 RB3 RB4 SX NB2 NB1 NB43 VS PAG 1 3 4 t C t C 1 2 3 4 t C t C 1 2 t C t C 1 2 5 6 1 2 1 2 3 4 5 6 1 2 3 4 1 2 t C t C 1 2 ...

Page 73: ...C 3 INT 4 RST 5 AUX1 6 AUX2 7 GND1 8 GND2 9 10 P16 MARRONE 11 10Vac 12 10Vac PIN 1 10Vac TRAFO 2 10Vac TRAFO 3 24Vac TRAFO P12 BLU P13 ROSA P16 NERO P11 VERDE 4 24Vac TRAFO PIN 1 EV_G2 2 COM_EDS 3 COM_AC 4 COM_AF 5 COM_EV 6 EV_EDS 7 EV_EVC 8 EV_AF PIN 1 VCC_DV3 2 SIG_DV3 3 GND_DV3 4 EV_EDS2 5 EV_G3 6 VCC_DV4 7 SIG_DV4 8 GND_DV4 PIN 1 COM_EVTS 2 3 COM_MC 4 MC 5 6 EV_EVTS PIN 1 24 ALIM 2 EV_EVP1 3 E...

Page 74: ... NTC_B3 4 NTC_B4 SENSORE PRESSIONE 1 2 ARANCIO SENSORE PRESSIONE 3 4 ARANCIO PIN 1 VCC_SP1 2 VCC_SP2 3 SIG_SP1 4 SIG_SP2 5 GND SP1 6 GND SP2 ARANCIO PIN 1 VCC_SP3 2 VCC_SP4 3 SIG_SP3 4 SIG_SP4 NTC BOILER 1 2 BIANCO 5 GND_SP1 6 GND_SP2 5 GND_SP3 6 GND_SP4 PIN 1 NTC_B2 2 NTC_B2 3 NTC_B1 4 NTC_B1 ...

Page 75: ...C_LED GR2 9 GND_LED GR2 TURBOSTEAM PIN 1 TS1 2 C_TS1 3 TS3 4 C TS3 3 TS3 4 C_TS3 5 TS2 6 C_TS2 7 STOP 8 C_STOP 9 TS4 10 C_TS4 LED GR3 BIANCO PIN 1 COM_LED SER 2 VCC_LED SER 3 GND LED SER 3 GND_LED SER LED GR4 BIANCO TASTIERE SK DISPLAY M100 GIALLO PIN 1 SDA 2 SCI PIN 1 COM_LED SER 2 VCC_LED SER 3 GND_LED SER ALIMENTAZIONE DISPLAY PIN 1 SDA 2 SCI 3 INT 4 RST 5 AUX1 6 AUX2 7 GND1 8 GND2 9 10 PIN 1 G...

Page 76: ...ed J7 Led gr 3 J8 Led gr 4 J9 Flat cable of services display gr 1 J10 Flat cable of gr 1 gr 2 gr 3 gr 4 display P1 Volumetric meter gr 1 gr 2 P3 Pressure sensor gr 3 gr 4 P4 Boiler NTC gr 3 gr 4 P5 Pressure sensor gr 1 gr 2 P6 Level sensor services boiler NTC P7 NTC boiler gr 1 gr 2 P8 Keyboards P9 Card feed P11 Proportional solenoid valve feed Gp P12 Solenoid valve feed G1 G2 Evc Eac Eds Va Eaf E...

Page 77: ...09 2015 A3 Title Size Design File Name Rev Date Sheet of Rev Date Description From Rev History ED ESM EDM EDAR ELF1 ELF EM Sml M MPL WB CN1 538080020 535904000 SCHEDA CONTABILITA SCHEDA CPU NEWTON 538020040 J3 CABLAGGIO COD CABLAGGIO COD 535934000 M MOTORE ELETTROVALVOLA LIVELLO REED CABLAGGIO COD 535934000 INSERIRE IN OUT_TM ...

Page 78: ...English 73 EN HYDRAULIC CIRCUIT ts Mix Eaf In 1 2 MC Ets Eac DV MP M100 DT 1547 1 2 Ev 1 2 Mn 15 10 1 5 0 6 M Evc Fi In 1 2 Eds In Vs Va Em ...

Page 79: ...valve Ev Steam solenoid valve Evc Boiler supply solenoid valve Fi Pump filter G Coffee solenoid valve Gc Coffee preparation group Eds Electronic Drying System In Injector ts Turbosteam selector Mix Water mixer Mn Pressure gauge MP Volumetric pump SL Boiler level probe MC Compressore motor Va Anti suction valve Vs Boiler safety valve HYDRAULIC DIAGRAM LEGEND ...

Page 80: ...5 10 1 5 0 6 Gp M 14 15 bar 1 2 Evc Fi Va Ed 1 3 2 Elf1 1 3 2 Ed Ht 1 3 2 1 2 Elf Reg Reg H C Esm Edar Mpl Turbosteam Turbomilk In M100 GT HD 1720 ACQUA MISCELATA ACQUA CALDA VAPORE ARIA LATTE ACQUA LAVAGGIO LATTE ACQUA LAVAGGIO RICIRCOLO WB Bm Bac Bv Vex 1 2 1 P 3 A Ø 2 5 mm Ø 4 mm A A B B Ø 1 mm Ø 0 8 mm ACQUA FREDDA ...

Page 81: ...d Diverter solenoid valve Elf Washing solenoid valve Esm Milk safety solenoid valve Edar Air diverter solenoid valve Fi Pump filter G Coffee solenoid valve Gp Proportional solenoid valve Ht Heater Bo Coffee boiler Bv Steam spout Edm Solenoid valve for milk deviation In Injector ts Turbosteam selector Mix Water mixer Mn Pressure gauge MP Volumetric pump Mpl Milk pump Reg Air regulator SL Boiler lev...

Page 82: ...his publication without notice Le fabricant se réserve le droit de modifier sans préavis les caractéristiques des appareils présentés dans cette publication Der Hersteller behält sich das Recht vor die in dieser Veröffentlichung vorgestellten Geräte ohne Vorankündigung zu ändern El Constructor se reserva el derecho de modificar sin preaviso las características de los equipos citados en este manual...