AVIATION RECORDERS
OPERATOR'S MANUAL
MODEL FA2100GSE
PORTABLE INTERFACE (PI)
DataLink Retrival
Rev. 05 Page 6
−
2
Sep. 06/13
6.3
WORD MONITOR MENU
The Word Monitor Menu is available only if the FDR is locked onto a stream of input flight data.
If this is not the case, attempts to access this screen will result in the message, “
No FDR
data
”. Various reasons for getting this message are, FDR recording is off, no Flight Data Ac-
quisition Unit (FDAU) stream is coming into the FDR, or the FDR cannot sync to the FDAU
stream. (See Status/Control for FDR recording turn-on procedure.)
6.4
SET MARKER
The Set Marker function is used to set a memory marker when recording to mark the beginning
of a specific recording segment. The FA2100 allows up to 15 memory markers to be set. This
method allows the user to dump data from the recorder from the point of the last memory
marker or any specific memory marker that has been set.