background image

X15 HIQ

rigging manual (EN)

Summary of Contents for X15 HIQ

Page 1: ...X15 HIQ rigging manual EN...

Page 2: ...g manual EN version 4 0 Distribution date June 12 2018 2018 L Acoustics All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means without the express...

Page 3: ...X BAR 15 Elements for pole mounting 17 Pole sockets 17 EMBi 17 Subwoofer 18 Rigging procedures 19 Mounting on a U bracket 19 Using a U bracket with X UTILT 23 Flying with a U bracket 29 Flying with X...

Page 4: ...igging accessories is respected Respect the maximum con gurations and the recommended safety precautions For safety issue respect the maximum con gurations outlined in this manual To check the conform...

Page 5: ...period of time Contact L Acoustics for advanced maintenance Any unauthorized maintenance operation will void the product warranty Symbols The following symbols are used in this document This symbol in...

Page 6: ...Q 2 way active coaxial enclosure 15 LF 3 HF diaphragm SB18 High power compact subwoofer 1 x 18 Rigging elements EMBi Pole mount socket 8XTi 12XTi and X series CLAMP250 Clamp certi ed for 250 kg X UTIL...

Page 7: ...System components Rigging elements EMBi X UTILT X BAR X UL15 X US1215 X15 HiQ rigging manual EN version 4 0 7...

Page 8: ...sory Maximum Safe limit Ground stacked No rigging accessory 1 Pole mounted 35 mm pole EMBi and X US1215 1 SB18 Con guration Rigging accessory Maximum Safe limit Ground stacked No rigging accessory 4 A...

Page 9: ...ed arrays a distinct stability warning is implemented in Soundvision It indicates a tipping hazard when the array is not secured to the ground stage or platform It is the user s responsibility to secu...

Page 10: ...features a M8 DIN580 threaded insert designed to implement a secondary safety The logo on the enclosure front can be rotated to adapt to every con guration X15 HiQ features ergonomic handles on both s...

Page 11: ...ion X15 HiQ features four runners on the bottom to protect the enclosure X15 HiQ features raisers that allow to change the monitor angle from 35 to 55 relative to the vertical CLICK X15 HiQ rigging ma...

Page 12: ...racket X US1215 or a long U bracket X UL15 The brackets are secured in the enclosure inserts with two threaded knobs A spring lock safety mechanism secures the knobs in the U brackets The threaded kno...

Page 13: ...et in horizontal position In this position the enclosure applies a diagonal force of 419 daN on the anchoring points Fasteners for wall mounting or ceiling mounting Secure the bracket with three M10 s...

Page 14: ...les consider the maximum site angle available See Maximum angles X US1215 features additional holes on the sides to closely t the enclosure and to optimize visual impact The knobs shall be stored in t...

Page 15: ...ion The site angle can be set from 0 to 45 in 5 steps The azimuth angle can be adjusted with the U bracket X UTILT shall only be used vertically Fasteners for wall mounting Secure the X UTILT with two...

Page 16: ...ll be secured to the inserts on the enclosure perpendicular to the front Five angulation holes are available 5 4 3 2 1 X BAR is compatible with a 12 mm shackle WLL 1 t provided and with CLAMP250 16 X1...

Page 17: ...ole mounting Pole sockets X15 HiQ features two 35 mm pole sockets integrated in the handles EMBi EMBi is a pole mount adapter for X US1215 35 mm pole The site angle can be adjusted with the U bracket...

Page 18: ...Rigging system description Subwoofer SB18 features a 35 mm pole socket 18 X15 HiQ rigging manual EN version 4 0...

Page 19: ...re 2 operators Short U bracket in horizontal position In this position the enclosure applies a diagonal force of 419 daN on the anchoring points Fasteners for wall mounting or ceiling mounting Secure...

Page 20: ...w length and anchors applicable to the wall or ceiling properties 2 Secure the U bracket to the wall using M10 screws 3 Lift the enclosure by the knobs and place it inside the U bracket Adjust the kno...

Page 21: ...Rigging procedures 5 Set the site angle Use the screw as a reference point to read the label 6 Tighten the knobs Make sure the enclosure is steady X15 HiQ rigging manual EN version 4 0 21...

Page 22: ...obs until the enclosure can rotate freely Do not unscrew the knobs all the way 2 On both sides pull on the safety mechanism while lifting the enclosure by the knobs to release it 3 Remove the U bracke...

Page 23: ...ent a secondary safety Fasteners for wall mounting Secure the X UTILT with two M10 screws Select screw length and anchors applicable to the wall properties The procedure is shown with X UL15 The same...

Page 24: ...rocedures 2 Secure the U bracket to X UTILT 3 Secure the rigging arm to the U bracket Make sure the rigging arm is in the correct position Always use the central insert 24 X15 HiQ rigging manual EN ve...

Page 25: ...10 15 20 25 30 35 40 45 5 Drive the knobs in the inserts on the enclosure Stop when the threading is halfway in 6 Lift the enclosure by the knobs and place it inside the U bracket Adjust the knobs on...

Page 26: ...procedures 7 Push until the knobs are locked inside the spring lock safety mechanism SHLAK 8 Set the azimuth angle Use the screw as a reference point to read the label 26 X15 HiQ rigging manual EN ver...

Page 27: ...Rigging procedures 9 Tighten the knobs Make sure the enclosure is steady X15 HiQ rigging manual EN version 4 0 27...

Page 28: ...until the enclosure can rotate freely Do not unscrew the knobs all the way 2 On both sides pull on the safety mechanism while sliding the enclosure out of the U bracket 3 Remove the U bracket and X U...

Page 29: ...he M8 DIN580 threaded insert to implement a secondary safety The procedure is shown with X US1215 The same procedure applies for X UL15 Assembly Procedure 1 Drive the knobs in the inserts on the enclo...

Page 30: ...l the knobs are locked inside the spring lock mechanism SHLAK Alternatively use the additional holes on the U bracket The hooks on the bracket must be oriented towards the front of the enclosure 30 X1...

Page 31: ...ety washer goes through the hole on the bracket 4 Tighten the knobs and y the enclosure with a clamp 5 Loosen the knobs to set the site angle Use the screw as a reference point to read the label X15 H...

Page 32: ...s 6 Tighten the knobs Make sure the enclosure is steady Maximum angles When using the additional holes on the U bracket consider the maximum negative site angle available 30 15 32 X15 HiQ rigging manu...

Page 33: ...procedures Disassembly Procedure 1 Place the enclosure on a at surface 2 Loosen the knobs 3 Pull on the safety mechanism and remove the U bracket from the enclosure X15 HiQ rigging manual EN version...

Page 34: ...ided additional material CLAMP250 optional min number of operators 1 Additional safety for own arrays When ying an array use the M8 DIN580 threaded insert to implement a secondary safety Assembly Proc...

Page 35: ...ular to the front grill Use the screws as reference points 4 Tighten the X BAR a Lift the lever and rotate it counter clockwise release the lever and rotate it clockwise Repeat until the X BAR is tigh...

Page 36: ...Rigging procedures b Finally store the lever on the right 36 X15 HiQ rigging manual EN version 4 0...

Page 37: ...te angle Rear extension on horizontal enclosure 22 5 14 5 4 14 Front extension on horizontal enclosure 4 5 14 22 30 38 Rear extension on vertical enclosure 5 5 1 5 8 5 15 22 Front extension on vertica...

Page 38: ...Rigging procedures 6 Lift the assembly 38 X15 HiQ rigging manual EN version 4 0...

Page 39: ...isassembly Procedure 1 Take down the assembly 2 Lift the lever and rotate it clockwise 3 Release the lever and rotate it counter clockwise 4 Repeat until the X BAR can be removed X15 HiQ rigging manua...

Page 40: ...tional material 35 mm pole min number of operators 1 Assembly Procedure 1 Secure EMBi to the U bracket with the provided bolts and nuts 2 Secure the U bracket to the enclosure using the additional hol...

Page 41: ...ough the hole on the bracket 3 Tighten the knobs reverse the assembly and mount it on a pole 4 Tighten EMBi 5 Loosen the knobs to set the site angle Consider the maximum positive site angle available...

Page 42: ...Rigging procedures 30 15 6 Tighten the knobs Make sure the enclosure is steady The assembly can be mounted on a tripod or on a subwoofer 42 X15 HiQ rigging manual EN version 4 0...

Page 43: ...this task Remove the assembly from the pole before disassembling the enclosure and the bracket Procedure 1 Loosen EMBi to remove the assembly from the pole 2 Remove the bracket from the enclosure X15...

Page 44: ...Forbidden con gurations Forbidden con gurations Forbidden Authorized 44 X15 HiQ rigging manual EN version 4 0...

Page 45: ...Forbidden con gurations Forbidden Authorized X15 HiQ rigging manual EN version 4 0 45...

Page 46: ...ss re ex L Vents ellipsoidal waveguide Nominal impedance LF 8 HF 8 Connectors IN 1 4 point speakON LINK 1 4 point speakON Rigging and handling 2 handles 1 DIN580 compatible M8 threaded insert 4 M10 th...

Page 47: ...Speci cations X15 HiQ dimensions 430 mm 16 9 in 375 mm 14 8 in 580 mm 22 8 in 471 mm 18 5 in 500 mm 19 7 in 341 mm 13 4 in 403 mm 15 9 in X15 HiQ rigging manual EN version 4 0 47...

Page 48: ...LINK 1 4 point speakON Rigging and handling 2 handles integrated into the cabinet captive rigging system 1 35 mm pole socket Weight net 52 kg 115 lb Cabinet rst grade Baltic birch plywood Front steel...

Page 49: ...Speci cations SB18 dimensions 750 mm 29 5 in 707 mm 27 8 in 553 mm 21 8 in X15 HiQ rigging manual EN version 4 0 49...

Page 50: ...ng U bracket for X15 HiQ Weight net 2 9 kg 6 4 lb Material high grade steel with anti corrosion coating X UL15 dimensions M10 643 mm 25 3 in 685 mm 27 in 341 mm 13 4 in 53 mm 2 1 in 96 mm 3 8 in 200 m...

Page 51: ...bracket for X12 and X15 HiQ Weight net 3 kg 6 6 lb Material high grade steel with anti corrosion coating X US1215 dimensions 535 mm 21 1 in 493 mm 19 4 in 470 mm 18 5 in M10 53 mm 2 1 in 80 mm 3 1 in...

Page 52: ...t wallmount for X series with tilt adjustment Weight net 1 5 kg 3 3 lb Material high grade steel with anti corrosion coating X UTILT dimensions 300 mm 11 8 in M10 55 mm 2 2 in 88 mm 3 5 in 65 mm 2 6 i...

Page 53: ...ion Rigging bar for X series 1 12 mm shackle WLL 1 t Weight net 1 1 kg 2 4 lb Material high grade steel with anti corrosion coating X BAR dimensions 185 mm 7 3 in 13 mm 0 5 in 83 mm 3 3 in 85 mm 3 3 i...

Page 54: ...ription Pole mount socket 8XTi 12XTi and X series Weight net 0 5 kg 1 lb Material high grade steel with anti corrosion coating EMBi dimensions 46 mm 1 8 in 35 mm 1 4 in 76 mm 3 in 115 5 mm 4 5 in 54 X...

Page 55: ...w l acoustics com L Acoustics GmbH Steierm rker Str 3 5 70469 Stuttgart Germany 49 7 11 89660 323 L Acoustics Ltd PO Box Adler Shine Aston House Cornwall Avenue London N3 1LF United Kingdom 44 7224 11...