CARE AND MAINTENANCE
8.1
Maintenance information
L-ACOUSTICS amplified controller are quality units and should provide years of trouble-free services when operated
under normal conditions. The only maintenance required is to clean the anti-dust cover on a regular basis (see section 8.2).
In some cases it may be necessary for authorized service personnel to clean the inside of the controller, especially after
long operation periods in very dusty or cracked-oil smoke machines environments.
Cleaning and servicing the inside of an amplified controller must be done by qualified personnel.
An amplifier that is considered to be unsafe must be labelled accordingly and stored in a safe place
to prevent this amplifier being used mistakenly.
8.2
Filter cleaning
The air intake on the front of your LA4 is fitted with a removable filter system. If the filter becomes
clogged the unit will not cool as efficiently as it should and may result in reduced output power
level performances
.
To clean or change the foam filter follow this procedure (see Figure27):
1.
Unclip the moulded front frame by pulling it towards you.
2.
Clean (with mild dishwashing detergent or soap) or change the foam filter.
3.
Replace the foam filter (when dry).
4.
Align the moulded front frame with its 2 clip aperture and push back into place.